These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
276 related articles for article (PubMed ID: 2395230)
1. [Estimation of scatter component in SPECT planar image using a Monte Carlo method]. Ogawa K; Harata Y; Ichihara T; Kubo A; Hashimoto S Kaku Igaku; 1990 May; 27(5):467-76. PubMed ID: 2395230 [TBL] [Abstract][Full Text] [Related]
2. [Quantitative assessment of scattered photons considering skull bone in brain SPECT]. Maeda S; Ogawa K Kaku Igaku; 1994 May; 31(5):431-9. PubMed ID: 8028215 [TBL] [Abstract][Full Text] [Related]
3. A modified TEW approach to scatter correction for In-111 and Tc-99m dual-isotope small-animal SPECT. Prior P; Timmins R; Petryk J; Strydhorst J; Duan Y; Wei L; Glenn Wells R Med Phys; 2016 Oct; 43(10):5503. PubMed ID: 27782731 [TBL] [Abstract][Full Text] [Related]
4. Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging. Dewaraja YK; Ljungberg M; Koral KF J Nucl Med; 2000 Jan; 41(1):123-30. PubMed ID: 10647615 [TBL] [Abstract][Full Text] [Related]
5. Monte Carlo evaluation of Compton scatter subtraction in single photon emission computed tomography. Floyd CE; Jaszczak RJ; Harris CC; Greer KL; Coleman RE Med Phys; 1985; 12(6):776-8. PubMed ID: 3878451 [TBL] [Abstract][Full Text] [Related]
6. Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators. Fan P; Hutton BF; Holstensson M; Ljungberg M; Pretorius PH; Prasad R; Ma T; Liu Y; Wang S; Thorn SL; Stacy MR; Sinusas AJ; Liu C Med Phys; 2015 Dec; 42(12):6895-911. PubMed ID: 26632046 [TBL] [Abstract][Full Text] [Related]
7. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras. Hannequin PP; Mas JF J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311 [TBL] [Abstract][Full Text] [Related]
8. Generalized dual-energy-window scatter compensation in spatially varying media for SPECT. Smith MF; Jaszczak RJ Phys Med Biol; 1994 Mar; 39(3):531-46. PubMed ID: 15551596 [TBL] [Abstract][Full Text] [Related]
9. Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition. Kojima A; Tsuji A; Takaki Y; Tomiguchi S; Hara M; Matsumoto M; Takahashi M Ann Nucl Med; 1992 Aug; 6(3):153-8. PubMed ID: 1389890 [TBL] [Abstract][Full Text] [Related]
10. A Monte Carlo study of multiple scatter effects in Compton scatter densitometry. Speller RD; Horrocks JA Med Phys; 1988; 15(5):707-12. PubMed ID: 3185406 [TBL] [Abstract][Full Text] [Related]
11. The effect of attenuation map, scatter energy window width, and volume of interest on the calibration factor calculation in quantitative Karimi Ghodoosi E; D'Alessandria C; Li Y; Bartel A; Köhner M; Höllriegl V; Navab N; Eiber M; Li WB; Frey E; Ziegler S Phys Med; 2018 Dec; 56():74-80. PubMed ID: 30527092 [TBL] [Abstract][Full Text] [Related]
12. Quantitative Monte Carlo-based holmium-166 SPECT reconstruction. Elschot M; Smits ML; Nijsen JF; Lam MG; Zonnenberg BA; van den Bosch MA; Viergever MA; de Jong HW Med Phys; 2013 Nov; 40(11):112502. PubMed ID: 24320461 [TBL] [Abstract][Full Text] [Related]
13. Effect of energy resolution on scatter fraction in scintigraphic imaging: Monte Carlo study. Kojima A; Matsumoto M; Takahashi M; Uehara S Med Phys; 1993; 20(4):1107-13. PubMed ID: 8413019 [TBL] [Abstract][Full Text] [Related]
14. Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study. Gustafsson A; Arlig A; Jacobsson L; Ljungberg M; Wikkelsö C Phys Med Biol; 2000 Nov; 45(11):3431-40. PubMed ID: 11098915 [TBL] [Abstract][Full Text] [Related]
15. Simulation study of triple-energy-window scatter correction in combined Tl-201, Tc-99m SPECT. Ogawa K Ann Nucl Med; 1994 Nov; 8(4):277-81. PubMed ID: 7702973 [TBL] [Abstract][Full Text] [Related]
16. Experimental analysis of scattered photons in Tc-99m imaging with a gamma camera. Kojima A; Matsumoto M; Takahashi M Ann Nucl Med; 1991 Nov; 5(4):139-44. PubMed ID: 1797068 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of scatter compensation methods by their effects on parameter estimation from SPECT projections. Moore SC; Kijewski MF; Müller SP; Rybicki F; Zimmerman RE Med Phys; 2001 Feb; 28(2):278-87. PubMed ID: 11243353 [TBL] [Abstract][Full Text] [Related]
18. Characterization of Compton-scatter imaging with an analytical simulation method. Jones KC; Redler G; Templeton A; Bernard D; Turian JV; Chu JCH Phys Med Biol; 2018 Jan; 63(2):025016. PubMed ID: 29243663 [TBL] [Abstract][Full Text] [Related]
19. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging. Ouyang J; El Fakhri G; Moore SC Med Phys; 2007 Aug; 34(8):3263-72. PubMed ID: 17879789 [TBL] [Abstract][Full Text] [Related]
20. Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging. Kojima A; Takaki A; Noguchi T; Matsumoto M; Katsuda N; Tomiguchi S; Yamashita Y Ann Nucl Med; 2005 Oct; 19(7):541-7. PubMed ID: 16363618 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]