259 related articles for article (PubMed ID: 2395253)
1. [A case of bioprosthetic mitral valvular dysfunction due to pannus-formation].
Takagi H; Terada Y; Shimoyama Y; Ino T; Wanibuchi Y; Furuta S
Kyobu Geka; 1990 Jul; 43(7):569-72. PubMed ID: 2395253
[TBL] [Abstract][Full Text] [Related]
2. Morphologic findings in explanted Hancock II porcine bioprostheses.
Butany J; Yu W; Silver MD; David TE
J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
[TBL] [Abstract][Full Text] [Related]
3. Malfunction of a Hancock bioprosthesis in the mitral position 24 years after initial implantation.
Niinami H; Naito Y; Koyanagi H; Nagashima H; Kasanuki H
J Heart Valve Dis; 2000 Nov; 9(6):810-2. PubMed ID: 11128790
[TBL] [Abstract][Full Text] [Related]
4. Mitral stenosis due to pannus overgrowth after rigid ring annuloplasty.
Oda T; Kato S; Tayama E; Fukunaga S; Akashi H; Aoyagi S
J Heart Valve Dis; 2010 Mar; 19(2):257-9. PubMed ID: 20369514
[TBL] [Abstract][Full Text] [Related]
5. Early mechanical failures of the Hancock pericardial xenograft.
Bortolotti U; Milano A; Thiene G; Guerra F; Mazzucco A; Valente M; Talenti E; Gallucci V
J Thorac Cardiovasc Surg; 1987 Aug; 94(2):200-7. PubMed ID: 3613618
[TBL] [Abstract][Full Text] [Related]
6. Repair for mitral stenosis due to pannus formation after Duran ring annuloplasty.
Song S; Cho SH; Yang JH; Park PW
Ann Thorac Surg; 2010 Dec; 90(6):e93-4. PubMed ID: 21095295
[TBL] [Abstract][Full Text] [Related]
7. [Structural changes of Hancock bioprostheses in children (author's transl)].
Bortolotti U; Milano A; Mazzucco A; Callucci V; Valente M; Del Maschio A; Valfrè C; Thiene G
G Ital Cardiol; 1980; 10(11):1520-5. PubMed ID: 7202899
[TBL] [Abstract][Full Text] [Related]
8. Mitral stenosis after mitral valve repair using the duran flexible annuloplasty ring for degenerative mitral regurgitation.
Nishida H; Takahara Y; Takeuchi S; Mogi K
J Heart Valve Dis; 2005 Jul; 14(4):563-4. PubMed ID: 16116886
[TBL] [Abstract][Full Text] [Related]
9. Long-lasting durability of Carpentier-Edwards pericardial bovine bioprosthesis in mitral position - a case report of unfavourable post redo valve surgery course.
Luczak K; Piestrzeniewicz K; Maciejewski M; Walczak A; Jaszewski R; Ostrowski S; Drozdz J
Kardiol Pol; 2010 Jul; 68(7):806-8; discussion 809. PubMed ID: 20648442
[TBL] [Abstract][Full Text] [Related]
10. [Redo double valve replacement in a patient with bioprosthetic valve malfunction by pannus formation; report of a case].
Hiranuma S; Nabuchi A; Okuyama H; Muto Y; Endo M
Kyobu Geka; 2014 Oct; 67(11):1017-20. PubMed ID: 25292380
[TBL] [Abstract][Full Text] [Related]
11. Results of reoperation for primary tissue failure of porcine bioprostheses.
Bortolotti U; Milano A; Mazzucco A; Valfré C; Talenti E; Guerra F; Thiene G; Gallucci V
J Thorac Cardiovasc Surg; 1985 Oct; 90(4):564-9. PubMed ID: 4046622
[TBL] [Abstract][Full Text] [Related]
12. Cicatricial changes in a Ionescu-Shiley bioprosthesis.
Walley VM; Stinson WA; Bedard P
J Heart Valve Dis; 1994 Nov; 3(6):690-1. PubMed ID: 8000615
[TBL] [Abstract][Full Text] [Related]
13. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year].
Matsuzaki K; Koishizawa T; Hiramatsu Y
Kyobu Geka; 1997 Oct; 50(11):950-3. PubMed ID: 9330518
[TBL] [Abstract][Full Text] [Related]
14. Twenty-eight-year survival of stent-mounted aortic homograft in the mitral position: case report.
Subramaniam G; Chowdhury UK; Seth S; Prusty S; Kumar AS
J Heart Valve Dis; 2005 Jul; 14(4):559-62. PubMed ID: 16116885
[TBL] [Abstract][Full Text] [Related]
15. [Intermittent opening of a mechanical mitral valve prosthesis due to pannus formation; report of a case].
Seo H; Sasaki Y; Hirai H; Hosono M; Sakaguchi M; Nagashima F; Nakahira A; Morisaki A; Okada Y; Suehiro S
Kyobu Geka; 2011 May; 64(5):415-8. PubMed ID: 21591446
[TBL] [Abstract][Full Text] [Related]
16. [Malfunction of the Omniscience valve in mitral position: a case report].
Ito T; Miyata Y; Oomiya T; Ariki H; Takagi Y; Ishihara T
Kyobu Geka; 1991 Nov; 44(12):1037-40. PubMed ID: 1758108
[TBL] [Abstract][Full Text] [Related]
17. Morphologic and histologic findings in bioprosthetic valves explanted from the mitral position in children younger than 5 years of age.
Gellis L; Baird CW; Emani S; Borisuk M; Gauvreau K; Padera RF; Sanders SP
J Thorac Cardiovasc Surg; 2018 Feb; 155(2):746-752. PubMed ID: 29102206
[TBL] [Abstract][Full Text] [Related]
18. Fibrous tissue overgrowth on Hancock mitral xenografts: a cause of late prosthetic stenosis.
Bortolotti U; Gallucci V; Casarotto D; Thiene G
Thorac Cardiovasc Surg; 1979 Oct; 27(5):316-8. PubMed ID: 524334
[TBL] [Abstract][Full Text] [Related]
19. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position].
Hayashi K; Nakano H; Sakamoto T; Okamura H
Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799
[TBL] [Abstract][Full Text] [Related]
20. [Stenosis of Carpentier-Edwards pericardial bioprosthesis in the tricuspid position caused by adhesion of native valve cusps to the bioprosthesis].
Nemoto S; Sakai A; Sudoh K; Kodera K; Abe M; Lim ZB; Oosawa M
Kyobu Geka; 1997 Nov; 50(12):1049-51. PubMed ID: 9388354
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]