130 related articles for article (PubMed ID: 2396018)
1. [Gamma-ray spectra of 201Tl-radiopharmaceuticals with a scintillation camera--crosstalk of contaminating nuclides of 200Tl and/or 202Tl onto 201Tl-photopeaks].
Saegusa K; Fukushi M; Katoh Y; Saitoh H; Irifune T
Radioisotopes; 1990 Jun; 39(6):255-60. PubMed ID: 2396018
[TBL] [Abstract][Full Text] [Related]
2. [Crosstalks onto photopeak windows of 99mTc and other radionuclide (201Tl, 123I or 111In) in simultaneous acquisitions using a scinticamera--a fundamental study through phantom experiments].
Saegusa K; Fukushi M; Saitoh H; Irifune T
Kaku Igaku; 1993 Feb; 30(2):209-16. PubMed ID: 8468806
[TBL] [Abstract][Full Text] [Related]
3. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride.
Staelens SG; de Wit TC; Lemahieu IA; Beekman FJ
Eur J Nucl Med Mol Imaging; 2008 May; 35(5):922-32. PubMed ID: 18219482
[TBL] [Abstract][Full Text] [Related]
4. Thallium-201: scintillation camera imaging considerations.
Groch MW; Lewis GK
J Nucl Med; 1976 Feb; 17(02):142-5. PubMed ID: 1245877
[TBL] [Abstract][Full Text] [Related]
5. New knowledge about the bremsstrahlung image of strontium-89 with the scintillation camera.
Narita H; Hirase K; Uchiyama M; Fukushi M
Ann Nucl Med; 2012 Aug; 26(7):603-7. PubMed ID: 22767009
[TBL] [Abstract][Full Text] [Related]
6. [Energy spectral analysis in a photopeak region of 201Hg X-rays for 201Tl imaging].
Kojima A; Matsumoto M; Oyama Y; Tomiguchi S; Kira M; Takahashi M
Kaku Igaku; 1997 Feb; 34(2):95-103. PubMed ID: 9095572
[TBL] [Abstract][Full Text] [Related]
7. Effects of asymmetric photopeak windows on flood field uniformity and spatial resolution of scintillation cameras.
Graham LS; LaFontaine RL; Stein MA
J Nucl Med; 1986 May; 27(5):706-13. PubMed ID: 3712085
[TBL] [Abstract][Full Text] [Related]
8. A rapid improved method for gamma-spectrometric determination of 202Tl impurities in [201Tl]-labelled radiopharmaceuticals.
Bonardi M; Groppi F; Birattari C
Appl Radiat Isot; 2002 Nov; 57(5):647-55. PubMed ID: 12433038
[TBL] [Abstract][Full Text] [Related]
9. [Experimental study on the location of energy windows for scatter correction by the TEW method in 201Tl imaging].
Kojima A; Matsumoto M; Ohyama Y; Tomiguchi S; Kira M; Takahashi M
Kaku Igaku; 1997 Sep; 34(9):831-6. PubMed ID: 9394551
[TBL] [Abstract][Full Text] [Related]
10. Revisiting gallium-67 imaging: investigation of the energy photopeaks.
Ali L; Khalil M; Hadi N
Nucl Med Commun; 2010 Dec; 31(12):1068-74. PubMed ID: 20881893
[TBL] [Abstract][Full Text] [Related]
11. Assessment of collimators in radium-223 imaging with channelized Hotelling observer: a simulation study.
Takahashi A; Baba S; Sasaki M
Ann Nucl Med; 2018 Dec; 32(10):649-657. PubMed ID: 30073570
[TBL] [Abstract][Full Text] [Related]
12. Long term retention and excretion of 201Tl in a patient after myocardial perfusion imaging.
Blanchardon E; Challeton-de Vathaire C; Boisson P; Célier D; Martin JC; Cassot S; Herbelet G; Franck D; Jourdain JR; Biau A
Radiat Prot Dosimetry; 2005; 113(1):47-53. PubMed ID: 15671052
[TBL] [Abstract][Full Text] [Related]
13. Ga-67 imaging with scintillation camera: the selection of collimator.
Shinohara H; Koga Y
J Nucl Med; 1981 Feb; 22(2):169-76. PubMed ID: 7463160
[TBL] [Abstract][Full Text] [Related]
14. Imaging 123I with a scintillation camera. A study of detection performance and quality factor concepts.
Bolmsjö MS; Persson BR; Strand SE
Phys Med Biol; 1977 Mar; 22(2):266-77. PubMed ID: 857263
[TBL] [Abstract][Full Text] [Related]
15. Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds in clinical practice.
Dobbeleir AA; Hambÿe AS; Franken PR
Eur J Nucl Med; 1999 Jun; 26(6):655-8. PubMed ID: 10369952
[TBL] [Abstract][Full Text] [Related]
16. A new method for the correction of gamma camera nonuniformity due to spatial distortion.
Johnson TK; Nelson C; Kirch DL
Phys Med Biol; 1996 Oct; 41(10):2179-88. PubMed ID: 8912389
[TBL] [Abstract][Full Text] [Related]
17. Physical characteristics of low and medium energy collimators for 123I imaging and simultaneous dual-isotope imaging.
Inoue Y; Shirouzu I; Machida T; Yoshizawa Y; Akita F; Doi I; Watadani T; Noda M; Yoshikawa K; Ohtomo K
Nucl Med Commun; 2003 Nov; 24(11):1195-202. PubMed ID: 14569175
[TBL] [Abstract][Full Text] [Related]
18. Error of uptake in dual energy acquisition with 201Tl and 123I labeled radiopharmaceuticals.
Nakajima K; Taki J; Bunko H; Shimizu M; Muramori A; Tonami N; Hisada K
Eur J Nucl Med; 1990; 16(8-10):595-9. PubMed ID: 2116968
[TBL] [Abstract][Full Text] [Related]
19. CdTe XG-Cam: A new high-resolution x-ray and gamma-ray camera for studies of the pharmacokinetics of radiopharmaceuticals in small animals.
Katsuragawa M; Yagishita A; Takeda S; Minami T; Ohnuki K; Fujii H; Takahashi T
Med Phys; 2024 May; ():. PubMed ID: 38762908
[TBL] [Abstract][Full Text] [Related]
20. Collimation for imaging the myocardium. II.
Graham LS; Poe ND; Robinson GD
J Nucl Med; 1976 Aug; 17(8):719-23. PubMed ID: 932817
[TBL] [Abstract][Full Text] [Related]