BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

574 related articles for article (PubMed ID: 23963035)

  • 1. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty.
    Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M
    Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial.
    MacDonald SJ; McCalden RW; Chess DG; Bourne RB; Rorabeck CH; Cleland D; Leung F
    Clin Orthop Relat Res; 2003 Jan; (406):282-96. PubMed ID: 12579029
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
    Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P
    Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of synovial fluid, urine, and serum ion levels in metal-on-metal total hip arthroplasty at a minimum follow-up of 18 years.
    Lass R; Grübl A; Kolb A; Stelzeneder D; Pilger A; Kubista B; Giurea A; Windhager R
    J Orthop Res; 2014 Sep; 32(9):1234-40. PubMed ID: 24841922
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of an alumina-on-alumina bearing system in total hip arthroplasty for osteonecrosis of the hip.
    Seyler TM; Bonutti PM; Shen J; Naughton M; Kester M
    J Bone Joint Surg Am; 2006 Nov; 88 Suppl 3():116-25. PubMed ID: 17079377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
    Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
    J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metal-on-polyethylene versus metal-on-metal bearing surfaces in total hip arthroplasty: a prospective randomised study investigating metal ion levels and chromosomal aberrations in peripheral lymphocytes.
    Briggs TW; Hanna SA; Kayani B; Tai S; Pollock RC; Cannon SR; Blunn GW; Carrington RW
    Bone Joint J; 2015 Sep; 97-B(9):1183-91. PubMed ID: 26330583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Large head metal-on-metal cementless total hip arthroplasty versus 28 mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial.
    Zijlstra WP; Bos N; van Raaij JJ
    BMC Musculoskelet Disord; 2008 Oct; 9():136. PubMed ID: 18842151
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
    Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL
    J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings.
    Savarino L; Granchi D; Ciapetti G; Cenni E; Nardi Pantoli A; Rotini R; Veronesi CA; Baldini N; Giunti A
    J Biomed Mater Res; 2002; 63(5):467-74. PubMed ID: 12209889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*.
    Levine BR; Hsu AR; Skipor AK; Hallab NJ; Paprosky WG; Galante JO; Jacobs JJ
    J Bone Joint Surg Am; 2013 Mar; 95(6):512-8. PubMed ID: 23515985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.
    Engh CA; MacDonald SJ; Sritulanondha S; Thompson A; Naudie D; Engh CA
    Clin Orthop Relat Res; 2009 Jan; 467(1):101-11. PubMed ID: 18855089
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systemic metal exposure in large- and small-diameter metal-on-metal total hip replacements.
    Daniel J; Ziaee H; Pradhan C; McMinn DJ
    Orthopedics; 2008 Dec; 31(12 Suppl 2):. PubMed ID: 19298017
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective, randomised controlled trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip replacement.
    Schouten R; Malone AA; Tiffen C; Frampton CM; Hooper G
    J Bone Joint Surg Br; 2012 Nov; 94(11):1462-7. PubMed ID: 23109623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cushion bearings versus large diameter head metal-on-metal bearings in total hip arthroplasty: a short-term metal ion study.
    Moroni A; Nocco E; Hoque M; Diremigio E; Buffoli D; Cantù F; Catalani S; Apostoli P
    Arch Orthop Trauma Surg; 2012 Jan; 132(1):123-9. PubMed ID: 21845437
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve.
    Lavigne M; Belzile EL; Roy A; Morin F; Amzica T; Vendittoli PA
    J Bone Joint Surg Am; 2011 May; 93 Suppl 2():128-36. PubMed ID: 21543702
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study.
    Witt F; Bosker BH; Bishop NE; Ettema HB; Verheyen CC; Morlock MM
    J Bone Joint Surg Am; 2014 Sep; 96(18):e157. PubMed ID: 25232087
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.