These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 2396740)

  • 1. Estimation of analytical values from sub-detection limit measurements for water quality parameters.
    Gaskin JE; Dafoe T; Brooksbank P
    Analyst; 1990 May; 115(5):507-10. PubMed ID: 2396740
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multivariate approach for the biometric comparison of analytical methods in clinical chemistry.
    Feldmann U; Schneider B; Klinkers H; Haeckel R
    J Clin Chem Clin Biochem; 1981 Mar; 19(3):121-37. PubMed ID: 7229577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Measurement uncertainty in drinking water analysis. Conclusions from interlaboratory tests].
    Koch M
    Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz; 2006 Oct; 49(10):1027-33. PubMed ID: 17013781
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Partly nonparametric approach for determining the limit of detection.
    Linnet K; Kondratovich M
    Clin Chem; 2004 Apr; 50(4):732-40. PubMed ID: 14764644
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Further aspects of a Markovian sampling policy for water quality monitoring.
    Smeach SC; Jernigan RW
    Biometrics; 1977 Mar; 33(1):41-6. PubMed ID: 843580
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of the quality of water using combined indicators].
    Novikov IuV; Plitman SI; Lastochkina KO; Khvastunov RM
    Gig Sanit; 1984 Nov; (11):7-11. PubMed ID: 6526295
    [No Abstract]   [Full Text] [Related]  

  • 7. Imputation of data values that are less than a detection limit.
    Succop PA; Clark S; Chen M; Galke W
    J Occup Environ Hyg; 2004 Jul; 1(7):436-41. PubMed ID: 15238313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-a-day electrochemical detection of coliforms in drinking water using a tyrosinase composite biosensor.
    Serra B; Morales MD; Zhang J; Reviejo AJ; Hall EH; Pingarron JM
    Anal Chem; 2005 Dec; 77(24):8115-21. PubMed ID: 16351163
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Synchronous spectrofluorimetric determination of total amounts of the six polycyclic aromatic hydrocarbons officially designated as indicators of drinking water quality.
    López de Alda-Villaizan MJ; García-Falcon S; Lage-Yusty MA; Simal-Lozano J
    J AOAC Int; 1995; 78(2):402-6. PubMed ID: 7756856
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of a between-run component of variation, choice of control limits, and shape of error distribution on the performance characteristics of rules for internal quality control.
    Westgard JO; Falk H; Groth T
    Clin Chem; 1979 Mar; 25(3):394-400. PubMed ID: 262178
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A hierarchical modeling approach for estimating national distributions of chemicals in public drinking water systems.
    Qian SS; Schulman A; Koplos J; Kotros A; Kellar P
    Environ Sci Technol; 2004 Feb; 38(4):1176-82. PubMed ID: 14998034
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Particle and microorganism enumeration data: enabling quantitative rigor and judicious interpretation.
    Emelko MB; Schmidt PJ; Reilly PM
    Environ Sci Technol; 2010 Mar; 44(5):1720-7. PubMed ID: 20121082
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Quality assurance for analytical laboratories].
    Cwiek-Ludwicka K; Karłowski K
    Rocz Panstw Zakl Hig; 1993; 44(2-3):123-32. PubMed ID: 8016532
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic simulation and parameter estimation in river streams.
    Karadurmus E; Berber R
    Environ Technol; 2004 Apr; 25(4):471-9. PubMed ID: 15214452
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Statistical studies for the determination of quality classification ranges in hydromicrobiological tests of flowing water].
    Täumer L; Reiher W
    Z Gesamte Hyg; 1976; 22(10):734-7. PubMed ID: 997625
    [No Abstract]   [Full Text] [Related]  

  • 16. Direct injection, simple and robust analysis of trace-level bromate and bromide in drinking water by IC with suppressed conductivity detection.
    Lawal W; Gandhi J; Zhang CC
    J Chromatogr Sci; 2010 Aug; 48(7):537-43. PubMed ID: 20819277
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of historical data for estimating the number of samples required for monitoring drinking water.
    el-Shaarawi AH; Block JC; Maul A
    Sci Total Environ; 1985 Apr; 42(3):289-303. PubMed ID: 4001922
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Validation of simple analytical equipment for arsenic].
    Uchino T; Tokunaga H; Ando M
    Kokuritsu Iyakuhin Shokuhin Eisei Kenkyusho Hokoku; 2000; (118):103-6. PubMed ID: 11534108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sequential-injection procedure for determination of iodide in pharmaceutical and drinking water samples by catalytic reaction with spectrophotometric detection.
    Erustes JA; Forteza R; Cerdà V
    J AOAC Int; 2001; 84(2):337-41. PubMed ID: 11324595
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of arsenic in water--quality assurance and calculation of metrological characteristics.
    Borosová D; Mocak J; Beinrohr E; Bobrowski A
    Cent Eur J Public Health; 2001 Nov; 9(4):196-8. PubMed ID: 11787248
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.