267 related articles for article (PubMed ID: 23968811)
1. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support.
Shah P; Mehta VM; Cowger JA; Aaronson KD; Pagani FD
J Heart Lung Transplant; 2014 Jan; 33(1):102-4. PubMed ID: 23968811
[No Abstract] [Full Text] [Related]
2. Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant.
Cowger JA; Romano MA; Shah P; Shah N; Mehta V; Haft JW; Aaronson KD; Pagani FD
J Heart Lung Transplant; 2014 Jan; 33(1):35-43. PubMed ID: 24418732
[TBL] [Abstract][Full Text] [Related]
3. Incidence of increases in pump power use and associated clinical outcomes with an axial continuous-flow ventricular assist device.
Steffen RJ; Soltesz EG; Miracle K; Lee S; Mountis M; Moazami N
J Heart Lung Transplant; 2014 Jan; 33(1):105-6. PubMed ID: 24418736
[No Abstract] [Full Text] [Related]
4. Hemolysis in left ventricular assist device: a retrospective analysis of outcomes.
Ravichandran AK; Parker J; Novak E; Joseph SM; Schilling JD; Ewald GA; Silvestry S
J Heart Lung Transplant; 2014 Jan; 33(1):44-50. PubMed ID: 24418733
[TBL] [Abstract][Full Text] [Related]
5. A novel link between G6PD deficiency and hemolysis in patients with continuous-flow left ventricular assist devices.
Alhosaini H; Jensen BC; Chang PP; Sheridan BC; Katz JN
J Heart Lung Transplant; 2014 Jan; 33(1):116-7. PubMed ID: 24290168
[No Abstract] [Full Text] [Related]
6. Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon.
Uriel N; Han J; Morrison KA; Nahumi N; Yuzefpolskaya M; Garan AR; Duong J; Colombo PC; Takayama H; Thomas S; Naka Y; Jorde UP
J Heart Lung Transplant; 2014 Jan; 33(1):51-9. PubMed ID: 24290832
[TBL] [Abstract][Full Text] [Related]
7. Discriminatory performance of positive urine hemoglobin for detection of significant hemolysis in patients with continuous-flow left ventricular assist devices.
Gavalas MV; Breskin A; Yuzefpolskaya M; Eisenberger A; Castagna F; Demmer RT; Flannery M; Garan AR; Takeda K; Takayama H; Naka Y; Topkara VK; Colombo PC
J Heart Lung Transplant; 2017 Jan; 36(1):59-63. PubMed ID: 27773451
[TBL] [Abstract][Full Text] [Related]
8. Continuous flow left ventricular assist device related aortic root thrombosis complicated by left main coronary artery occlusion.
Shah S; Mehra MR; Couper GS; Desai AS
J Heart Lung Transplant; 2014 Jan; 33(1):119-20. PubMed ID: 24418738
[No Abstract] [Full Text] [Related]
9. Uncommon Cause of Hemolysis With Rapid Decrease in Mechanical Circulatory Support Flow.
Nordan T; Ortoleva J; Chen FY; Kapur NK; Couper GS; Kawabori M
Circ Heart Fail; 2021 Jan; 14(1):e007312. PubMed ID: 33435696
[No Abstract] [Full Text] [Related]
10. Device thrombosis in continuous-flow left ventricular assist devices: a new manifestation of Kounis syndrome?
Kounis NG; Soufras GD; Davlouros P
J Heart Lung Transplant; 2014 Jun; 33(6):665. PubMed ID: 24726423
[No Abstract] [Full Text] [Related]
11. The use of eptifibatide for suspected pump thrombus or thrombosis in patients with left ventricular assist devices.
Tellor BR; Smith JR; Prasad SM; Joseph SM; Silvestry SC
J Heart Lung Transplant; 2014 Jan; 33(1):94-101. PubMed ID: 24418735
[TBL] [Abstract][Full Text] [Related]
12. Hematologic markers better predict left ventricular assist device thrombosis than echocardiographic or pump parameters.
Bartoli CR; Ghotra AS; Pachika AR; Birks EJ; McCants KC
Thorac Cardiovasc Surg; 2014 Aug; 62(5):414-8. PubMed ID: 24995532
[TBL] [Abstract][Full Text] [Related]
13. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.
Birschmann I; Dittrich M; Eller T; Wiegmann B; Reininger AJ; Budde U; StrĂ¼ber M
J Heart Lung Transplant; 2014 Jan; 33(1):80-7. PubMed ID: 24418734
[TBL] [Abstract][Full Text] [Related]
14. Continuous-flow left ventricular assist device exchange: clinical outcomes.
Ota T; Yerebakan H; Akashi H; Takayama H; Uriel N; Colombo PC; Jorde UP; Naka Y
J Heart Lung Transplant; 2014 Jan; 33(1):65-70. PubMed ID: 23937885
[TBL] [Abstract][Full Text] [Related]
15. Clinical and In Vitro Evidence That Subclinical Hemolysis Contributes to LVAD Thrombosis.
Bartoli CR; Zhang D; Kang J; Hennessy-Strahs S; Restle D; Howard J; Redline G; Bermudez C; Atluri P; Acker MA
Ann Thorac Surg; 2018 Mar; 105(3):807-814. PubMed ID: 28942075
[TBL] [Abstract][Full Text] [Related]
16. Pump Thrombosis: A Limitation of Contemporary Left Ventricular Assist Devices.
Kapur NK; Vest AR; Cook J; Kiernan MS
Curr Probl Cardiol; 2015 Dec; 40(12):511-40. PubMed ID: 26542611
[TBL] [Abstract][Full Text] [Related]
17. Thrombolysis for suspected intrapump thrombosis in patients with continuous flow centrifugal left ventricular assist device.
Muthiah K; Robson D; Macdonald PS; Keogh AM; Kotlyar E; Granger E; Dhital K; Spratt P; Jansz P; Hayward CS
Artif Organs; 2013 Mar; 37(3):313-8. PubMed ID: 23373528
[TBL] [Abstract][Full Text] [Related]
18. Novel thrombosis risk index as predictor of left ventricular assist device thrombosis.
Trivedi JR; Sobieski MA; Schwartz S; Williams ML; Slaughter MS
ASAIO J; 2013; 59(4):380-3. PubMed ID: 23820276
[TBL] [Abstract][Full Text] [Related]
19. Clinical implications of LDH isoenzymes in hemolysis and continuous-flow left ventricular assist device-induced thrombosis.
Gordon JS; Wood CT; Luc JGY; Watson RA; Maynes EJ; Choi JH; Morris RJ; Massey HT; Throckmorton AL; Tchantchaleishvili V
Artif Organs; 2020 Mar; 44(3):231-238. PubMed ID: 31494952
[TBL] [Abstract][Full Text] [Related]
20. Unexpected abrupt increase in left ventricular assist device thrombosis.
Starling RC; Moazami N; Silvestry SC; Ewald G; Rogers JG; Milano CA; Rame JE; Acker MA; Blackstone EH; Ehrlinger J; Thuita L; Mountis MM; Soltesz EG; Lytle BW; Smedira NG
N Engl J Med; 2014 Jan; 370(1):33-40. PubMed ID: 24283197
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]