BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 23970963)

  • 1. High-frequency oscillatory ventilation combined with volume guarantee in a neonatal animal model of respiratory distress syndrome.
    Sánchez Luna M; Santos González M; Tendillo Cortijo F
    Crit Care Res Pract; 2013; 2013():593915. PubMed ID: 23970963
    [TBL] [Abstract][Full Text] [Related]  

  • 2. DCO
    González-Pacheco N; Sánchez-Luna M; Arribas-Sánchez C; Santos-González M; Orden-Quinto C; Tendillo-Cortijo F
    Eur J Pediatr; 2020 Mar; 179(3):499-506. PubMed ID: 31823075
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of the I/E ratio on CO2 removal during high-frequency oscillatory ventilation with volume guarantee in a neonatal animal model of RDS.
    Sánchez-Luna M; González-Pacheco N; Santos M; Blanco Á; Orden C; Belik J; Tendillo FJ
    Eur J Pediatr; 2016 Oct; 175(10):1343-51. PubMed ID: 27595847
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of very low tidal volumes during high-frequency ventilation reduces ventilator lung injury.
    González-Pacheco N; Sánchez-Luna M; Chimenti-Camacho P; Santos-González M; Palau-Concejo P; Tendillo-Cortijo F
    J Perinatol; 2019 May; 39(5):730-736. PubMed ID: 30770883
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of High-Frequency Oscillatory Ventilation With Volume Guarantee During Surfactant Treatment in Extremely Low Gestational Age Newborns With Respiratory Distress Syndrome: An Observational Study.
    Tana M; Paladini A; Tirone C; Aurilia C; Lio A; Bottoni A; Costa S; Tiberi E; Pastorino R; Vento G
    Front Pediatr; 2021; 9():804807. PubMed ID: 35310140
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volume Guarantee High-Frequency Oscillatory Ventilation in Preterm Infants With RDS: Tidal Volume and DCO
    Tuzun F; Deliloglu B; Cengiz MM; Iscan B; Duman N; Ozkan H
    Front Pediatr; 2020; 8():105. PubMed ID: 32266185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-frequency oscillatory ventilation with volume guarantee: a single-centre experience.
    Belteki G; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2019 Jul; 104(4):F384-F389. PubMed ID: 30217870
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lung recruitment in neonatal high-frequency oscillatory ventilation with volume-guarantee.
    Solis-Garcia G; González-Pacheco N; Ramos-Navarro C; Vigil-Vázquez S; Gutiérrez-Vélez A; Merino-Hernández A; Rodríguez Sánchez De la Blanca A; Sánchez-Luna M
    Pediatr Pulmonol; 2022 Dec; 57(12):3000-3008. PubMed ID: 35996817
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact on cerebral hemodynamics of the use of volume guarantee combined with high frequency oscillatory ventilation in a neonatal animal respiratory distress model.
    Pérez-Pérez A; González-Pacheco N; Arriaga-Redondo M; Ramos-Navarro C; Rodríguez-Corrales E; de la Blanca AR; González-Navarro P; Santos-González M; Sánchez-Luna M
    Eur J Pediatr; 2024 Jan; 183(1):157-167. PubMed ID: 37851085
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New Ventilator Strategies: High-Frequency Oscillatory Ventilation Combined with Volume Guarantee.
    Sánchez-Luna M; González-Pacheco N; Belik J; Santos M; Tendillo F
    Am J Perinatol; 2018 May; 35(6):545-548. PubMed ID: 29694993
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of Volume Guarantee on High-Frequency Oscillatory Ventilation in Preterm Infants: A Randomized Crossover Clinical Trial.
    Iscan B; Duman N; Tuzun F; Kumral A; Ozkan H
    Neonatology; 2015; 108(4):277-82. PubMed ID: 26330156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of high-frequency oscillation ventilation combined with volume guarantee in infants with acute hypoxic respiratory failure after congenital heart surgery.
    Zheng YR; Xie WP; Liu JF; Wu HL; Xu N; Huang ST; Cao H; Chen Q
    Pediatr Pulmonol; 2021 Aug; 56(8):2621-2626. PubMed ID: 33964188
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New indicators for optimal lung recruitment during high frequency oscillator ventilation.
    Rodríguez Sánchez de la Blanca A; Sánchez Luna M; González Pacheco N; Ramos Navarro C; Santos González M; Tendillo Cortijo F
    Pediatr Pulmonol; 2020 Dec; 55(12):3525-3531. PubMed ID: 32965770
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodynamic effects of high frequency oscillatory ventilation with volume guarantee in a piglet model of respiratory distress syndrome.
    Bhogal J; Solevåg AL; O'Reilly M; Lee TF; Joynt C; Hornberger LK; Schmölzer GM; Cheung PY
    PLoS One; 2021; 16(2):e0246996. PubMed ID: 33592023
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome.
    Muellenbach RM; Kredel M; Zollhoefer B; Wunder C; Roewer N; Brederlau J
    BMC Anesthesiol; 2006 Jun; 6():8. PubMed ID: 16792808
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correlations between volume delivery (VTHF) in course of high frequency oscillatory ventilation (HFOV) and severity of respiratory distress.
    Lista G; Fontana P; Castoldi F; Marangione P; Menchini M; Compagnoni G
    Pediatr Med Chir; 2004; 26(2):124-5. PubMed ID: 15700736
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the immature lung. A pilot study.
    González-Pacheco N; Sánchez-Luna M; Ramos-Navarro C; Navarro-Patiño N; de la Blanca AR
    J Perinatol; 2016 Apr; 36(4):306-10. PubMed ID: 26741575
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimal mean airway pressure during high-frequency oscillatory ventilation in an experimental model of acute respiratory distress syndrome: EIT-based method.
    Liu S; Zhao Z; Tan L; Wang L; Möller K; Frerichs I; Yu T; Huang Y; Pan C; Yang Y; Qiu H
    Ann Intensive Care; 2020 Mar; 10(1):31. PubMed ID: 32144514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-frequency oscillatory ventilation reduces lung inflammation: a large-animal 24-h model of respiratory distress.
    Muellenbach RM; Kredel M; Said HM; Klosterhalfen B; Zollhoefer B; Wunder C; Redel A; Schmidt M; Roewer N; Brederlau J
    Intensive Care Med; 2007 Aug; 33(8):1423-33. PubMed ID: 17563879
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Specific compliance and gas exchange during high-frequency oscillatory ventilation.
    Wood B; Karna P; Adams A
    Crit Care Med; 2002 Jul; 30(7):1523-7. PubMed ID: 12130973
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.