945 related articles for article (PubMed ID: 23981926)
1. Does Navigation Improve Accuracy of Placement of Pedicle Screws in Single-level Lumbar Degenerative Spondylolisthesis?: A Comparison Between Free-hand and Three-dimensional O-Arm Navigation Techniques.
Boon Tow BP; Yue WM; Srivastava A; Lai JM; Guo CM; Wearn Peng BC; Chen JL; Yew AK; Seng C; Tan SB
J Spinal Disord Tech; 2015 Oct; 28(8):E472-7. PubMed ID: 23981926
[TBL] [Abstract][Full Text] [Related]
2. Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: radiological and clinical study in 100 consecutive patients.
Costa F; Cardia A; Ortolina A; Fabio G; Zerbi A; Fornari M
Spine (Phila Pa 1976); 2011 Nov; 36(24):2094-8. PubMed ID: 21304425
[TBL] [Abstract][Full Text] [Related]
3. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
Ravindra VM; Kalra RR; Dailey AT
Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
[TBL] [Abstract][Full Text] [Related]
4. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
Malham GM; Parker RM
J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
[TBL] [Abstract][Full Text] [Related]
5. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.
Jin M; Liu Z; Liu X; Yan H; Han X; Qiu Y; Zhu Z
Eur Spine J; 2016 Jun; 25(6):1729-37. PubMed ID: 25967559
[TBL] [Abstract][Full Text] [Related]
6. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.
Van de Kelft E; Costa F; Van der Planken D; Schils F
Spine (Phila Pa 1976); 2012 Dec; 37(25):E1580-7. PubMed ID: 23196967
[TBL] [Abstract][Full Text] [Related]
7. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
Raley DA; Mobbs RJ
Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
[TBL] [Abstract][Full Text] [Related]
8. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.
Wang Y; Xie J; Yang Z; Zhao Z; Zhang Y; Li T; Liu L
Arch Orthop Trauma Surg; 2013 Jul; 133(7):901-9. PubMed ID: 23632781
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery.
Nakashima H; Sato K; Ando T; Inoh H; Nakamura H
J Spinal Disord Tech; 2009 Oct; 22(7):468-72. PubMed ID: 20075808
[TBL] [Abstract][Full Text] [Related]
10. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
[TBL] [Abstract][Full Text] [Related]
11. Radiographic feasibility study of cortical bone trajectory and traditional pedicle screw dual trajectories.
Mullin JP; Perlmutter B; Schmidt E; Benzel E; Steinmetz MP
J Neurosurg Spine; 2016 Dec; 25(6):727-732. PubMed ID: 27391396
[TBL] [Abstract][Full Text] [Related]
12. [Posterior lumbar fusion using the O-arm surgical imaging system: initial experience].
Castro Castro J; Rodino Padín J; Pinzón Millán A; Agulleiro Díaz JP; Villa Fernández JM; Pastor Zapata A
Neurocirugia (Astur); 2013; 24(1):1-8. PubMed ID: 23246338
[TBL] [Abstract][Full Text] [Related]
13. Comparison between free-hand and O-arm-based navigated posterior lumbar interbody fusion in elderly cohorts with three-level lumbar degenerative disease.
Wang Y; Chen K; Chen H; Zhang K; Lu J; Mao H; Yang H
Int Orthop; 2019 Feb; 43(2):351-357. PubMed ID: 29876628
[TBL] [Abstract][Full Text] [Related]
14. Robot-assisted Percutaneous Transfacet Screw Fixation Supplementing Oblique Lateral Interbody Fusion Procedure: Accuracy and Safety Evaluation of This Novel Minimally Invasive Technique.
Wu JY; Yuan Q; Liu YJ; Sun YQ; Zhang Y; Tian W
Orthop Surg; 2019 Feb; 11(1):25-33. PubMed ID: 30776856
[TBL] [Abstract][Full Text] [Related]
15. Incidence and risk factors for the misplacement of pedicle screws in scoliosis surgery assisted by O-arm navigation-analysis of a large series of one thousand, one hundred and forty five screws.
Jin M; Liu Z; Qiu Y; Yan H; Han X; Zhu Z
Int Orthop; 2017 Apr; 41(4):773-780. PubMed ID: 27999927
[TBL] [Abstract][Full Text] [Related]
16. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical evaluation of lumbar pedicle screws in spondylolytic vertebrae: comparison of fixation strength between the traditional trajectory and a cortical bone trajectory.
Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Asazuma T; Chiba K
J Neurosurg Spine; 2016 Jun; 24(6):910-5. PubMed ID: 26895531
[TBL] [Abstract][Full Text] [Related]
18. Computed tomography-guided C2 pedicle screw placement for treatment of unstable hangman fractures.
Singh PK; Garg K; Sawarkar D; Agarwal D; Satyarthee GD; Gupta D; Sinha S; Kale SS; Sharma BS
Spine (Phila Pa 1976); 2014 Aug; 39(18):E1058-65. PubMed ID: 25122548
[TBL] [Abstract][Full Text] [Related]
19. Comparing Next-Generation Robotic Technology with 3-Dimensional Computed Tomography Navigation Technology for the Insertion of Posterior Pedicle Screws.
Khan A; Meyers JE; Yavorek S; O'Connor TE; Siasios I; Mullin JP; Pollina J
World Neurosurg; 2019 Mar; 123():e474-e481. PubMed ID: 30500593
[TBL] [Abstract][Full Text] [Related]
20. Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation.
Chachan S; Bin Abd Razak HR; Loo WL; Allen JC; Shree Kumar D
Eur Spine J; 2018 Nov; 27(11):2729-2736. PubMed ID: 29651593
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]