125 related articles for article (PubMed ID: 23982064)
1. Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre/epoxy plate for Vancouver B1 femur fractures.
Siddiqui FS; Shah S; Nicayenzi B; Schemitsch EH; Zdero R; Bougherara H
Proc Inst Mech Eng H; 2014 Jan; 228(1):107-13. PubMed ID: 23982064
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate.
Bagheri ZS; Tavakkoli Avval P; Bougherara H; Aziz MS; Schemitsch EH; Zdero R
J Biomech Eng; 2014 Sep; 136(9):091002. PubMed ID: 24828985
[TBL] [Abstract][Full Text] [Related]
3. On optimization of a composite bone plate using the selective stress shielding approach.
Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
J Mech Behav Biomed Mater; 2015 Feb; 42():138-53. PubMed ID: 25482217
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
[TBL] [Abstract][Full Text] [Related]
5. The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures.
Choi JK; Gardner TR; Yoon E; Morrison TA; Macaulay WB; Geller JA
J Arthroplasty; 2010 Sep; 25(6 Suppl):124-8. PubMed ID: 20558031
[TBL] [Abstract][Full Text] [Related]
6. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position.
Dubov A; Kim SY; Shah S; Schemitsch EH; Zdero R; Bougherara H
Proc Inst Mech Eng H; 2011 Sep; 225(9):857-65. PubMed ID: 22070023
[TBL] [Abstract][Full Text] [Related]
7. A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation.
Dhason R; Roy S; Datta S
Comput Methods Programs Biomed; 2020 Nov; 196():105680. PubMed ID: 32763643
[TBL] [Abstract][Full Text] [Related]
8. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?
Shah S; Kim SY; Dubov A; Schemitsch EH; Bougherara H; Zdero R
Proc Inst Mech Eng H; 2011 Sep; 225(9):845-56. PubMed ID: 22070022
[TBL] [Abstract][Full Text] [Related]
9. The effect of strut allograft and its position on Vancouver type B1 periprosthetic femoral fractures: a biomechanical study.
Sariyilmaz K; Dikici F; Dikmen G; Bozdag E; Sunbuloglu E; Bekler B; Yazicioglu O
J Arthroplasty; 2014 Jul; 29(7):1485-90. PubMed ID: 24656637
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.
Bagheri ZS; El Sawi I; Bougherara H; Zdero R
J Mech Behav Biomed Mater; 2014 Jul; 35():27-38. PubMed ID: 24727574
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical Analysis Using FEA and Experiments of Metal Plate and Bone Strut Repair of a Femur Midshaft Segmental Defect.
Coquim J; Clemenzi J; Salahi M; Sherif A; Tavakkoli Avval P; Shah S; Schemitsch EH; Bagheri ZS; Bougherara H; Zdero R
Biomed Res Int; 2018; 2018():4650308. PubMed ID: 30420962
[TBL] [Abstract][Full Text] [Related]
12. What is the risk of stress risers for interprosthetic fractures of the femur? A biomechanical analysis.
Lehmann W; Rupprecht M; Nuechtern J; Melzner D; Sellenschloh K; Kolb J; Fensky F; Hoffmann M; Püschel K; Morlock M; Rueger JM
Int Orthop; 2012 Dec; 36(12):2441-6. PubMed ID: 23132503
[TBL] [Abstract][Full Text] [Related]
13. The influence of composite bone plates in Vancouver femur B1 fracture fixation after post-operative, and healed bone stages: A finite element study.
Dhason R; Roy S; Datta S
Proc Inst Mech Eng H; 2022 Sep; 236(9):1288-1296. PubMed ID: 35920405
[TBL] [Abstract][Full Text] [Related]
14. Can plate osteosynthesis of periprosthethic femoral fractures cause cement mantle failure around a stable hip stem? A biomechanical analysis.
Giesinger K; Ebneter L; Day RE; Stoffel KK; Yates PJ; Kuster MS
J Arthroplasty; 2014 Jun; 29(6):1308-12. PubMed ID: 24439999
[TBL] [Abstract][Full Text] [Related]
15. Double plating in Vancouver type B1 periprosthetic proximal femur fractures: A biomechanical study.
Wähnert D; Grüneweller N; Gehweiler D; Brunn B; Raschke MJ; Stange R
J Orthop Res; 2017 Feb; 35(2):234-239. PubMed ID: 27061941
[TBL] [Abstract][Full Text] [Related]
16. Periprosthetic femoral fracture--a biomechanical comparison between Vancouver type B1 and B2 fixation methods.
Moazen M; Mak JH; Etchels LW; Jin Z; Wilcox RK; Jones AC; Tsiridis E
J Arthroplasty; 2014 Mar; 29(3):495-500. PubMed ID: 24035619
[TBL] [Abstract][Full Text] [Related]
17. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
Crist BD; Khalafi A; Hazelwood SJ; Lee MA
J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
[TBL] [Abstract][Full Text] [Related]
18. Angulated locking plate in periprosthetic proximal femur fractures: biomechanical testing of a new prototype plate.
Lenz M; Gueorguiev B; Joseph S; van der Pol B; Richards RG; Windolf M; Schwieger K; de Boer P
Arch Orthop Trauma Surg; 2012 Oct; 132(10):1437-44. PubMed ID: 22707211
[TBL] [Abstract][Full Text] [Related]
19. Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty.
Chen DW; Lin CL; Hu CC; Wu JW; Lee MS
Injury; 2012 Jul; 43(7):1061-5. PubMed ID: 22336128
[TBL] [Abstract][Full Text] [Related]
20. Plate Positioning in Periprosthetic or Interprosthetic Femur Fractures With Stable Implants-A Biomechanical Study.
Walcher MG; Giesinger K; du Sart R; Day RE; Kuster MS
J Arthroplasty; 2016 Dec; 31(12):2894-2899. PubMed ID: 27381372
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]