These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 23989825)

  • 1. A linearization time-domain CMOS smart temperature sensor using a curvature compensation oscillator.
    Chen CC; Chen HW
    Sensors (Basel); 2013 Aug; 13(9):11439-52. PubMed ID: 23989825
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Curvature-correction-based time-domain CMOS smart temperature sensor with an inaccuracy of -0.8 °C-1.2 °C after one-point calibration from -40 °C to 120 °C.
    Chen CC; Lin SH; Lin Y
    Rev Sci Instrum; 2014 Jun; 85(6):065005. PubMed ID: 24985845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. All-Digital Time-Domain CMOS Smart Temperature Sensor with On-Chip Linearity Enhancement.
    Chen CC; Chen CL; Lin Y
    Sensors (Basel); 2016 Jan; 16(2):176. PubMed ID: 26840316
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A time-domain CMOS oscillator-based thermostat with digital set-point programming.
    Chen CC; Lin SH
    Sensors (Basel); 2013 Jan; 13(2):1679-91. PubMed ID: 23385403
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A CMOS smart temperature and humidity sensor with combined readout.
    Eder C; Valente V; Donaldson N; Demosthenous A
    Sensors (Basel); 2014 Sep; 14(9):17192-211. PubMed ID: 25230305
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A linearity-enhanced time-domain CMOS thermostat with process-variation calibration.
    Chen CC; Lin Y
    Sensors (Basel); 2014 Oct; 14(10):18784-99. PubMed ID: 25310469
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Temperature-to-Frequency Converter-Based On-Chip Temperature Sensor with an Inaccuracy of +0.65 °C/-0.49 °C.
    Xu Z; Zhang X; Chen S; Cheong J; Yao L
    Sensors (Basel); 2023 May; 23(11):. PubMed ID: 37299896
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Area-efficient all-digital pulse-shrinking smart temperature sensor with improved accuracy and resolution.
    Chen CC; Hwang CS; Chu CS
    Rev Sci Instrum; 2018 Dec; 89(12):125002. PubMed ID: 30599587
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A 0.0016 mm² 0.64 nJ leakage-based CMOS temperature sensor.
    Ituero P; López-Vallejo M; López-Barrio C
    Sensors (Basel); 2013 Sep; 13(9):12648-62. PubMed ID: 24051526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An Energy-Efficient BJT-Based Temperature Sensor with ±0.8 °C (3
    Qin C; Huang Z; Liu Y; Li J; Lin L; Tan N; Yu X
    Sensors (Basel); 2022 Dec; 22(23):. PubMed ID: 36502079
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A 0.026 mm
    Park S; Byun S
    Micromachines (Basel); 2020 Sep; 11(10):. PubMed ID: 32998308
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sol-gel zinc oxide humidity sensors integrated with a ring oscillator circuit on-a-chip.
    Yang MZ; Dai CL; Wu CC
    Sensors (Basel); 2014 Oct; 14(11):20360-71. PubMed ID: 25353984
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An Optical and Temperature Assisted CMOS ISFET Sensor Array for Robust E. Coli Detection.
    Duan M; Zhong X; Zhao X; El-Agnaf OM; Lee YK; Bermak A
    IEEE Trans Biomed Circuits Syst; 2021 Jun; 15(3):497-508. PubMed ID: 34043514
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A 0.0014 mm
    Yang W; Jiang H; Wang Z
    Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31013907
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Short- and long-term stability of resonant quartz temperature sensors.
    Spassov L; Gadjanova V; Velcheva R; Dulmet B
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1626-31. PubMed ID: 18986952
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Highly Accurate, Polynomial-Based Digital Temperature Compensation for Piezoresistive Pressure Sensor in 180 nm CMOS Technology.
    Ali I; Asif M; Shehzad K; Rehman MRU; Kim DG; Rikan BS; Pu Y; Yoo SS; Lee KY
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32937979
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of an Embedded CMOS Temperature Sensor for Passive RFID Tag Chips.
    Deng F; He Y; Li B; Zhang L; Wu X; Fu Z; Zuo L
    Sensors (Basel); 2015 May; 15(5):11442-53. PubMed ID: 25993518
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wireless Low-Power Integrated Basal-Body-Temperature Detection Systems Using Teeth Antennas in the MedRadio Band.
    Yang CL; Zheng GT
    Sensors (Basel); 2015 Nov; 15(11):29467-77. PubMed ID: 26610508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel high-frequency, high-power, pulsed oscillator based on a transmission line transformer.
    Burdt R; Curry RD
    Rev Sci Instrum; 2007 Jul; 78(7):074703. PubMed ID: 17672783
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermal waveguide OPO.
    Lin ST; Lin YY; Wang TD; Huang YC
    Opt Express; 2010 Jan; 18(2):1323-9. PubMed ID: 20173959
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.