These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 23993077)

  • 21. Three-dimensional path planning software-assisted transjugular intrahepatic portosystemic shunt: a technical modification.
    Tsauo J; Luo X; Ye L; Li X
    Cardiovasc Intervent Radiol; 2015 Jun; 38(3):742-6. PubMed ID: 24934737
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Feasibility study of needle placement in percutaneous vertebroplasty: cone-beam computed tomography guidance versus conventional fluoroscopy.
    Braak SJ; Zuurmond K; Aerts HC; van Leersum M; Overtoom TT; van Heesewijk JP; van Strijen MJ
    Cardiovasc Intervent Radiol; 2013 Aug; 36(4):1120-6. PubMed ID: 23511990
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A rare case of portosystemic shunt: Variation of Abernethy malformation.
    Lee A; Eifer D; Nguyen ET
    J Cardiovasc Comput Tomogr; 2018; 12(2):168-169. PubMed ID: 29233631
    [No Abstract]   [Full Text] [Related]  

  • 24. Impact of 3D Rotational Angiography on Liver Embolization Procedures: Review of Technique and Applications.
    Lucatelli P; Corona M; Argirò R; Anzidei M; Vallati G; Fanelli F; Bezzi M; Catalano C
    Cardiovasc Intervent Radiol; 2015 Jun; 38(3):523-35. PubMed ID: 25488820
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Replaced right hepatic artery coursing ventral to the portal vein: demonstration with 64-row CT and 3D reformatted images.
    Duchat F; Soyer P; Malzy P; Boudiaf M; Rymer R
    Clin Imaging; 2009; 33(1):59-61. PubMed ID: 19135932
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.
    González-García R; Monje F
    Clin Oral Implants Res; 2013 Aug; 24(8):871-9. PubMed ID: 22250839
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Image fusion during vascular and nonvascular image-guided procedures.
    Abi-Jaoudeh N; Kobeiter H; Xu S; Wood BJ
    Tech Vasc Interv Radiol; 2013 Sep; 16(3):168-76. PubMed ID: 23993079
    [TBL] [Abstract][Full Text] [Related]  

  • 28. C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules.
    Hwang HS; Chung MJ; Lee JW; Shin SW; Lee KS
    AJR Am J Roentgenol; 2010 Dec; 195(6):W400-7. PubMed ID: 21098171
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Shading correction algorithm for improvement of cone-beam CT images in radiotherapy.
    Marchant TE; Moore CJ; Rowbottom CG; MacKay RI; Williams PC
    Phys Med Biol; 2008 Oct; 53(20):5719-33. PubMed ID: 18824785
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cone beam computed tomography scanning and diagnosis for dental implants.
    Greenberg AM
    Oral Maxillofac Surg Clin North Am; 2015 May; 27(2):185-202. PubMed ID: 25951956
    [TBL] [Abstract][Full Text] [Related]  

  • 31. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology.
    Orth RC; Wallace MJ; Kuo MD;
    J Vasc Interv Radiol; 2008 Jun; 19(6):814-20. PubMed ID: 18503894
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intraoperative cone-beam computed tomography in oral and maxillofacial surgery using a C-arm prototype: first clinical experiences after treatment of zygomaticomaxillary complex fractures.
    Pohlenz P; Blake F; Blessmann M; Smeets R; Habermann C; Begemann P; Schmelzle R; Heiland M
    J Oral Maxillofac Surg; 2009 Mar; 67(3):515-21. PubMed ID: 19231774
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Interventional multidimodal hybrid unit: from pre-operative planning to immediate post-operative control].
    Scolozzi P; Schouman T
    Rev Stomatol Chir Maxillofac; 2012 Apr; 113(2):115-23. PubMed ID: 22398193
    [TBL] [Abstract][Full Text] [Related]  

  • 34. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications.
    Floridi C; Radaelli A; Abi-Jaoudeh N; Grass M; Lin M; Chiaradia M; Geschwind JF; Kobeiter H; Squillaci E; Maleux G; Giovagnoni A; Brunese L; Wood B; Carrafiello G; Rotondo A
    Radiol Med; 2014 Jul; 119(7):521-32. PubMed ID: 25012472
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy.
    Braak SJ; Herder GJ; van Heesewijk JP; van Strijen MJ
    Cardiovasc Intervent Radiol; 2012 Dec; 35(6):1414-21. PubMed ID: 22146973
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Three-dimensional computed tomography image based endovascular treatment for hepatic vein.
    Ninomiya M; Ikeda T; Shirabe K; Kayashima H; Harimoto N; Iguchi T; Sugimachi K; Yamashita Y; Ikegami T; Saeki H; Oki E; Uchiyama H; Yoshizumi T; Soejima Y; Kawanaka H; Morita M; Maehara Y
    Fukuoka Igaku Zasshi; 2013 Nov; 104(11):469-72. PubMed ID: 24620644
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cone-beam computed tomography-guided percutaneous radiologic gastrostomy.
    Möhlenbruch M; Nelles M; Thomas D; Willinek W; Gerstner A; Schild HH; Wilhelm K
    Cardiovasc Intervent Radiol; 2010 Apr; 33(2):315-20. PubMed ID: 19597883
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Three-dimensional imaging of portal and hepatic veins using helical CT with intravenous injection of contrast medium].
    Ichikawa T; Kumazaki T; Ohya T; Tajima H; Kawamata H; Hayashi H; Takagi R
    Nihon Igaku Hoshasen Gakkai Zasshi; 1994 Nov; 54(13):1312-3. PubMed ID: 7610036
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dental cone beam computed tomography: justification for use in planning oral implant placement.
    Jacobs R; Quirynen M
    Periodontol 2000; 2014 Oct; 66(1):203-13. PubMed ID: 25123769
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Real-Time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility.
    Braak SJ; van Strijen MJ; van Leersum M; van Es HW; van Heesewijk JP
    AJR Am J Roentgenol; 2010 May; 194(5):W445-51. PubMed ID: 20410392
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.