BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 23995727)

  • 1. A case of nitinol allergy causing pericardial tamponade.
    Jain M; Singh S; Cadeiras M
    J Invasive Cardiol; 2013 Sep; 25(9):E180-2. PubMed ID: 23995727
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcatheter closure of atrial septal defect with atrial septal occluder in a patient with nickel allergy.
    Arı H; Arı S; Tütüncü A; Karakuş A; Melek M
    Turk Kardiyol Dern Ars; 2017 Jun; 45(4):355-357. PubMed ID: 28595206
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interatrial shunt closure devices in patients with nickel allergy.
    Reddy BT; Patel JB; Powell DL; Michaels AD
    Catheter Cardiovasc Interv; 2009 Oct; 74(4):647-51. PubMed ID: 19777603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nickel allergy induced systemic reaction to an intracardiac amplatzer device.
    Prestipino F; Pragliola C; Lusini M; Chello M
    J Card Surg; 2014 May; 29(3):349-50. PubMed ID: 24762035
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surgical explantation of atrial septal closure devices for refractory nickel allergy symptoms.
    Sharma V; DeShazo RA; Skidmore CR; Glotzbach JP; Koliopoulou A; Javan H; McKellar SH; Powell DL; Selzman CH
    J Thorac Cardiovasc Surg; 2020 Aug; 160(2):502-509.e1. PubMed ID: 31959452
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nickel hypersensitivity reaction following Amplatzer atrial septal defect occluder device deployment successfully treated by explantation of the device.
    Spina R; Muller DWM; Jansz P; Gunalingam B
    Int J Cardiol; 2016 Nov; 223():242-243. PubMed ID: 27541664
    [No Abstract]   [Full Text] [Related]  

  • 7. Pericarditis associated with nickel hypersensitivity to the Amplatzer occluder device: a case report.
    Lai DW; Saver JL; Araujo JA; Reidl M; Tobis J
    Catheter Cardiovasc Interv; 2005 Nov; 66(3):424-6. PubMed ID: 16208708
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Self-expanding platinum-coated nitinol devices for transcatheter closure of atrial septal defect: prevention of nickel release.
    Lertsapcharoen P; Khongphatthanayothin A; Srimahachota S; Leelanukrom R
    J Invasive Cardiol; 2008 Jun; 20(6):279-83. PubMed ID: 18523320
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Positive reactions to nickel on a patch test do not predict clinical outcome of nickel alloy-based atrial septal defect occluder implantation.
    Kim HJ; Shin JU; Lee J; Lee H; Jin S; Kim SH; Noh JY; Lee KH
    Dermatology; 2015; 230(2):184-8. PubMed ID: 25634825
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Two Percutaneous Atrial Septal Defect Occluders for Device Healing and Nickel Release in a Chronic Porcine Model.
    Jalal Z; Boudjemline Y; Iriart X; Seguela PE; Delmond S; Loyer V; Gonthier D; Bernus O; Durand M; Bordenave L; Thambo JB
    J Interv Cardiol; 2020; 2020():8413831. PubMed ID: 32665769
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade.
    Tchantchaleishvili V; Melvin AL; Ling FS; Knight PA
    Interact Cardiovasc Thorac Surg; 2014 Dec; 19(6):1074-6. PubMed ID: 25183740
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous closure of patent foramen ovale with Atriasept II device in nickel allergic patients.
    Cammalleri V; Ussia GP; Marchei M; Muscoli S; Sergi D; Macrini M; Romeo F
    J Cardiovasc Med (Hagerstown); 2014 Apr; 15(4):350-2. PubMed ID: 24685961
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nickel hypersensitivity following closure of atrial septal defect: A case report and review of the literature.
    Dickison P; Harris V; Smith SD
    Australas J Dermatol; 2018 Aug; 59(3):220-222. PubMed ID: 29380348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Severe Migraine Associated With Nickel Allergy Requiring Surgical Removal of Atrial Septal Device.
    Fernandes P; Sharma SR; Magee A; Michielon G; Fraisse A
    Ann Thorac Surg; 2019 Sep; 108(3):e183-e184. PubMed ID: 30794784
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Explantation of an atrial septal occluder device in a patient with nickel hypersensitivity.
    Uğuz E; Erdoğan K; Sener E
    Anadolu Kardiyol Derg; 2014 Jun; 14(4):402-3. PubMed ID: 24818974
    [No Abstract]   [Full Text] [Related]  

  • 16. Nickel for your thoughts: Survey of the Congenital Cardiovascular Interventional Study Consortium (CCISC) for nickel allergy.
    Gordon BM; Moore JW
    J Invasive Cardiol; 2009 Jul; 21(7):326-9. PubMed ID: 19571342
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal allergy to Amplatzer occluder device presented as severe bronchospasm.
    Khodaverdian RA; Jones KW
    Ann Thorac Surg; 2009 Dec; 88(6):2021-2. PubMed ID: 19932286
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nickel allergy, how deep?
    Anselmino M; Ribezzo M; Orzan F
    Acta Cardiol; 2009 Feb; 64(1):104-6. PubMed ID: 19317307
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nickel release after implantation of the Amplatzer occluder.
    Ries MW; Kampmann C; Rupprecht HJ; Hintereder G; Hafner G; Meyer J
    Am Heart J; 2003 Apr; 145(4):737-41. PubMed ID: 12679773
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Very late erosion of Amplatzer septal occluder device presenting as pericardial pain and effusion 8 years after placement.
    Roberts WT; Parmar J; Rajathurai T
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E592-4. PubMed ID: 23172721
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.