BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1419 related articles for article (PubMed ID: 23996969)

  • 1. Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: comparison with a drug eluting stent and a bare metal stent.
    Clever YP; Cremers B; Speck U; Dietz U; Böhm M; Scheller B
    Catheter Cardiovasc Interv; 2014 Aug; 84(2):323-31. PubMed ID: 23996969
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Paclitaxcel-coated balloon plus bare metal stent vs. sirolimus-eluting stent in de novo lesions: an IVUS study.
    Fischer D; Scheller B; Schäfer A; Klein G; Böhm M; Clever Y; Cremers B
    EuroIntervention; 2012 Aug; 8(4):450-5. PubMed ID: 22917728
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR
    Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Randomized evaluation of two drug-eluting stents with identical metallic platform and biodegradable polymer but different agents (paclitaxel or sirolimus) compared against bare stents: 1-year results of the PAINT trial.
    Lemos PA; Moulin B; Perin MA; Oliveira LA; Arruda JA; Lima VC; Lima AA; Caramori PR; Medeiros CR; Barbosa MR; Brito FS; Ribeiro EE; Martinez EE;
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):665-73. PubMed ID: 19670303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis: the three-year results of the PEPCAD II ISR study.
    Unverdorben M; Vallbracht C; Cremers B; Heuer H; Hengstenberg C; Maikowski C; Werner GS; Antoni D; Kleber FX; Bocksch W; Leschke M; Ackermann H; Boxberger M; Speck U; Degenhardt R; Scheller B
    EuroIntervention; 2015 Dec; 11(8):926-34. PubMed ID: 25169589
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first.
    Gutiérrez-Chico JL; van Geuns RJ; Koch KT; Koolen JJ; Duckers H; Regar E; Serruys PW
    EuroIntervention; 2011 Oct; 7(6):711-22. PubMed ID: 21986329
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Paclitaxel-coated balloon with bare-metal stenting in patients with chronic total occlusions in native coronary arteries.
    Wöhrle J; Werner GS
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):793-9. PubMed ID: 22511572
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods.
    Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR
    EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment of Coronary Drug-Eluting Stent Restenosis by a Sirolimus- or Paclitaxel-Coated Balloon.
    Ali RM; Abdul Kader MASK; Wan Ahmad WA; Ong TK; Liew HB; Omar AF; Mahmood Zuhdi AS; Nuruddin AA; Schnorr B; Scheller B
    JACC Cardiovasc Interv; 2019 Mar; 12(6):558-566. PubMed ID: 30898253
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent).
    Alfonso F; Pérez-Vizcayno MJ; Cárdenas A; García Del Blanco B; Seidelberger B; Iñiguez A; Gómez-Recio M; Masotti M; Velázquez MT; Sanchís J; García-Touchard A; Zueco J; Bethencourt A; Melgares R; Cequier A; Dominguez A; Mainar V; López-Mínguez JR; Moreu J; Martí V; Moreno R; Jiménez-Quevedo P; Gonzalo N; Fernández C; Macaya C;
    J Am Coll Cardiol; 2014 Apr; 63(14):1378-86. PubMed ID: 24412457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
    Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
    EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Twelve-month results of a paclitaxel releasing balloon in patients presenting with in-stent restenosis First-in-Man (PEPPER) trial.
    Hehrlein C; Dietz U; Kubica J; Jørgensen E; Hoffmann E; Naber C; Lesiak M; Schneider H; Wiemer M; Tölg R; Richardt G
    Cardiovasc Revasc Med; 2012; 13(5):260-4. PubMed ID: 22867706
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Catheter-based delivery of fluid paclitaxel for prevention of restenosis in native coronary artery lesions after stent implantation.
    Herdeg C; Göhring-Frischholz K; Haase KK; Geisler T; Zürn C; Hartmann U; Wöhrle J; Nusser T; Dippon J; May AE; Gawaz M
    Circ Cardiovasc Interv; 2009 Aug; 2(4):294-301. PubMed ID: 20031731
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficacy of a seal-wing paclitaxel-eluting balloon catheters in the treatment of bare metal stent restenosis.
    Pleva L; Kukla P; Zapletalova J; Hlinomaz O
    BMC Cardiovasc Disord; 2017 Jun; 17(1):168. PubMed ID: 28651572
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and safety of a double-coated paclitaxel-eluting coronary stent: the EUCATAX trial.
    Rodriguez AE; Vigo CF; Delacasa A; Mieres J; Fernandez-Pereira C; Bernardi V; Bettinoti M; Rodriguez-Granillo AM; Rodriguez-Granillo G; Santaera O; Curotto V; Rubilar B; Tronge J; Palacios IF; Antoniucci D;
    Catheter Cardiovasc Interv; 2011 Feb; 77(3):335-42. PubMed ID: 20824769
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Description of Pantera Lux paclitaxel-releasing balloon and preliminary quantitative coronary angiography (QCA) results at six months in patients with coronary in-stent restenosis.
    Hehrlein C; Richardt G; Wiemer M; Schneider H; Naber C; Hoffmann E; Dietz U
    EuroIntervention; 2011 May; 7 Suppl K():K119-24. PubMed ID: 22027721
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials.
    Doi H; Maehara A; Mintz GS; Yu A; Wang H; Mandinov L; Popma JJ; Ellis SG; Grube E; Dawkins KD; Weissman NJ; Turco MA; Ormiston JA; Stone GW
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1269-75. PubMed ID: 20129555
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between catheter-based delivery of paclitaxel after bare-metal stenting and drug-eluting stents in coronary artery disease patients at high risk for in-stent restenosis.
    El-Mokadem M; El-Ramly M; Hassan A; Boshra H; AbdelWahab A
    Cardiovasc Revasc Med; 2017 Dec; 18(8):596-600. PubMed ID: 28625402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Drug-Coated Balloon Versus Drug-Eluting Stent for Small-Vessel Disease: The RESTORE SVD China Randomized Trial.
    Tang Y; Qiao S; Su X; Chen Y; Jin Z; Chen H; Xu B; Kong X; Pang W; Liu Y; Yu Z; Li X; Li H; Zhao Y; Wang Y; Li W; Tian J; Guan C; Xu B; Gao R;
    JACC Cardiovasc Interv; 2018 Dec; 11(23):2381-2392. PubMed ID: 30522667
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 71.