324 related articles for article (PubMed ID: 23999783)
21. Optimized T1-MPRAGE sequence for better visualization of spinal cord multiple sclerosis lesions at 3T.
Nair G; Absinta M; Reich DS
AJNR Am J Neuroradiol; 2013; 34(11):2215-22. PubMed ID: 23764721
[TBL] [Abstract][Full Text] [Related]
22. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla.
Lavdas E; Vlychou M; Arikidis N; Kapsalaki E; Roka V; Fezoulidis IV
Acta Radiol; 2010 Apr; 51(3):290-5. PubMed ID: 20170294
[TBL] [Abstract][Full Text] [Related]
23. Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T.
Ozturk A; Aygun N; Smith SA; Caffo B; Calabresi PA; Reich DS
Neuroradiology; 2013 Mar; 55(4):431-9. PubMed ID: 23208410
[TBL] [Abstract][Full Text] [Related]
24. Diagnosis of hepatic metastasis: comparison of respiration-triggered diffusion-weighted echo-planar MRI and five t2-weighted turbo spin-echo sequences.
Bruegel M; Gaa J; Waldt S; Woertler K; Holzapfel K; Kiefer B; Rummeny EJ
AJR Am J Roentgenol; 2008 Nov; 191(5):1421-9. PubMed ID: 18941080
[TBL] [Abstract][Full Text] [Related]
25. MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence.
Notohamiprodjo M; Horng A; Pietschmann MF; Müller PE; Horger W; Park J; Crispin A; del Olmo JR; Weckbach S; Herrmann KA; Reiser MF; Glaser C
Invest Radiol; 2009 Sep; 44(9):585-97. PubMed ID: 19668001
[TBL] [Abstract][Full Text] [Related]
26. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques.
Lee SS; Byun JH; Hong HS; Park SH; Won HJ; Shin YM; Lee MG
J Magn Reson Imaging; 2007 Aug; 26(2):323-30. PubMed ID: 17610287
[TBL] [Abstract][Full Text] [Related]
27. [Comparison of T2-weighted turbo spin-echo and ultrafast HASTE sequence in the diagnosis of cervical myelopathies and spinal stenoses and static and kinematic MRT of the spine].
Muhle C; Metzner J; Brinkmann G; Kühn B; Bischoff L; Hutzelmann A; Wesner F; Heller M
Rofo; 1997 Nov; 167(5):467-73. PubMed ID: 9440891
[TBL] [Abstract][Full Text] [Related]
28. Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation-triggered prospective acquisition correction (PACE) T2-weighted MRI (T2WI) of the liver.
Nanko S; Oshima H; Watanabe T; Sasaki S; Hara M; Shibamoto Y
J Magn Reson Imaging; 2009 Aug; 30(2):321-6. PubMed ID: 19629991
[TBL] [Abstract][Full Text] [Related]
29. [Improved magnetic resonance myelography using image fusion].
Eberhardt K; Ganslandt O; Stadlbauer A
Rofo; 2013 Apr; 185(4):333-9. PubMed ID: 23348124
[TBL] [Abstract][Full Text] [Related]
30. A comparison of sagittal short T1 inversion recovery and T2-weighted FSE sequences for detection of multiple sclerosis spinal cord lesions.
Nayak NB; Salah R; Huang JC; Hathout GM
Acta Neurol Scand; 2014 Mar; 129(3):198-203. PubMed ID: 23980614
[TBL] [Abstract][Full Text] [Related]
31. Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: initial experience.
Michaely HJ; Kramer H; Weckbach S; Dietrich O; Reiser MF; Schoenberg SO
J Magn Reson Imaging; 2008 Jan; 27(1):148-53. PubMed ID: 18050324
[TBL] [Abstract][Full Text] [Related]
32. Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T--initial experience.
Hori M; Kim T; Onishi H; Ueguchi T; Tatsumi M; Nakamoto A; Tsuboyama T; Tomoda K; Tomiyama N
Radiology; 2011 Jan; 258(1):154-63. PubMed ID: 21045182
[TBL] [Abstract][Full Text] [Related]
33. Liver T2-weighted MR imaging: assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla.
Denoiseux CC; Boulay-Coletta I; Nakache JP; Claude ID; Zins M
J Magn Reson Imaging; 2013 Aug; 38(2):336-43. PubMed ID: 23239080
[TBL] [Abstract][Full Text] [Related]
34. Reliability analysis of the epidural spinal cord compression scale.
Bilsky MH; Laufer I; Fourney DR; Groff M; Schmidt MH; Varga PP; Vrionis FD; Yamada Y; Gerszten PC; Kuklo TR
J Neurosurg Spine; 2010 Sep; 13(3):324-8. PubMed ID: 20809724
[TBL] [Abstract][Full Text] [Related]
35. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.
Telegrafo M; Rella L; Stabile Ianora AA; Angelelli G; Moschetta M
Magn Reson Imaging; 2015 Oct; 33(8):951-5. PubMed ID: 26117691
[TBL] [Abstract][Full Text] [Related]
36. Spinal cord functional MRI at 3 T: gradient echo echo-planar imaging versus turbo spin echo.
Bouwman CJ; Wilmink JT; Mess WH; Backes WH
Neuroimage; 2008 Nov; 43(2):288-96. PubMed ID: 18706507
[TBL] [Abstract][Full Text] [Related]
37. Application of turbo fluid-attenuated inversion-recovery MRI in evaluation of intraspinal tumors.
Sun J; Zhang S; Jiang D; Zhang D; Xu X
Clin Imaging; 2008; 32(2):103-8. PubMed ID: 18313573
[TBL] [Abstract][Full Text] [Related]
38. Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI.
Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS
Magn Reson Imaging; 2013 Jun; 31(5):703-6. PubMed ID: 23290476
[TBL] [Abstract][Full Text] [Related]
39. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence.
Ciftci E; Anik Y; Arslan A; Akansel G; Sarisoy T; Demirci A
Eur J Radiol; 2004 Sep; 51(3):234-40. PubMed ID: 15294330
[TBL] [Abstract][Full Text] [Related]
40. Magnetic resonance T2 image signal intensity ratio and clinical manifestation predict prognosis after surgical intervention for cervical spondylotic myelopathy.
Zhang YZ; Shen Y; Wang LF; Ding WY; Xu JX; He J
Spine (Phila Pa 1976); 2010 May; 35(10):E396-9. PubMed ID: 20393392
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]