These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 24001048)

  • 1. Positive Biomechanical Effects of Titanium Oxide for Sandblasting Implant Surface as an Alternative to Aluminium Oxide.
    Gehrke SA; Taschieri S; Del Fabbro M; Coelho PG
    J Oral Implantol; 2015 Oct; 41(5):515-22. PubMed ID: 24001048
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of osseointegration on various implant surfaces after bacterial contamination and cleaning: a rabbit study.
    Yuan K; Chan YJ; Kung KC; Lee TM
    Int J Oral Maxillofac Implants; 2014; 29(1):32-40. PubMed ID: 24451851
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative evaluation between aluminium and titanium dioxide microparticles for blasting the surface titanium dental implants: an experimental study in rabbits.
    Gehrke SA; Ramírez-Fernandez MP; Granero Marín JM; Barbosa Salles M; Del Fabbro M; Calvo Guirado JL
    Clin Oral Implants Res; 2018 Jul; 29(7):802-807. PubMed ID: 27663612
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching.
    Cho SA; Park KT
    Biomaterials; 2003 Sep; 24(20):3611-7. PubMed ID: 12809791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque.
    Elias CN; Oshida Y; Lima JH; Muller CA
    J Mech Behav Biomed Mater; 2008 Jul; 1(3):234-42. PubMed ID: 19627788
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V).
    Granato R; Bonfante EA; Castellano A; Khan R; Jimbo R; Marin C; Morsi S; Witek L; Coelho PG
    J Mech Behav Biomed Mater; 2019 Sep; 97():288-295. PubMed ID: 31146202
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Relationship between the surface energy and the histologic results of different titanium surfaces.
    Gehrke SA; Zizzari VL; Iaculli F; Mortellaro C; Tetè S; Piattelli A
    J Craniofac Surg; 2014 May; 25(3):863-7. PubMed ID: 24820714
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Osseointegration of two different phosphate ion-containing titanium oxide surfaces in rabbit cancellous bone.
    Park JW
    Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():145-51. PubMed ID: 22251085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration.
    Yurttutan ME; Keskin A
    BMC Oral Health; 2018 Mar; 18(1):47. PubMed ID: 29554893
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.
    Klokkevold PR; Nishimura RD; Adachi M; Caputo A
    Clin Oral Implants Res; 1997 Dec; 8(6):442-7. PubMed ID: 9555202
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
    Hoffmann O; Angelov N; Zafiropoulos GG; Andreana S
    Int J Oral Maxillofac Implants; 2012; 27(2):352-8. PubMed ID: 22442775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Residual aluminum oxide on the surface of titanium implants has no effect on osseointegration.
    Piattelli A; Degidi M; Paolantonio M; Mangano C; Scarano A
    Biomaterials; 2003 Oct; 24(22):4081-9. PubMed ID: 12834604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical and Morphometric Evaluation of a Strontium-Incorporated Implant and Four Commercially Available Implants: A Study in Rabbits.
    Wu YF; Lin GF; Zhang LF; He FM
    Int J Oral Maxillofac Implants; 2020; 35(3):531-541. PubMed ID: 32406650
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface analysis of machined versus sandblasted and acid-etched titanium implants.
    Orsini G; Assenza B; Scarano A; Piattelli M; Piattelli A
    Int J Oral Maxillofac Implants; 2000; 15(6):779-84. PubMed ID: 11151575
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model.
    Ernst S; Stübinger S; Schüpbach P; Sidler M; Klein K; Ferguson SJ; von Rechenberg B
    Clin Oral Implants Res; 2015 Aug; 26(8):898-908. PubMed ID: 24954017
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants.
    Espinar-Escalona E; Bravo-Gonzalez LA; Pegueroles M; Gil FJ
    Clin Oral Investig; 2016 Jun; 20(5):1115-20. PubMed ID: 26955833
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface characterization, biomechanical, and histologic evaluation of alumina and bioactive resorbable blasting textured surfaces in titanium implant healing chambers: an experimental study in dogs.
    Witek L; Marin C; Granato R; Bonfante EA; Campos FE; Gomes JB; Suzuki M; Coelho PG
    Int J Oral Maxillofac Implants; 2013; 28(3):694-700. PubMed ID: 23748299
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of five different implant surfaces and their effect on osseointegration: a study in dogs.
    Coelho PG; Bonfante EA; Pessoa RS; Marin C; Granato R; Giro G; Witek L; Suzuki M
    J Periodontol; 2011 May; 82(5):742-50. PubMed ID: 21054223
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of Biomineralization on Osseointegration of Pure Titanium Implants in the Mandible of Beagles.
    Mei S; Dong F; Rahman Khan MS
    J Oral Maxillofac Surg; 2018 Oct; 76(10):2104.e1-2104.e10. PubMed ID: 30006302
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia.
    Cordioli G; Majzoub Z; Piattelli A; Scarano A
    Int J Oral Maxillofac Implants; 2000; 15(5):668-74. PubMed ID: 11055134
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.