193 related articles for article (PubMed ID: 24005581)
21. The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations.
Reynaert N; Coghe M; De Smedt B; Paelinck L; Vanderstraeten B; De Gersem W; Van Duyse B; De Wagter C; De Neve W; Thierens H
Phys Med Biol; 2005 Mar; 50(5):831-46. PubMed ID: 15798258
[TBL] [Abstract][Full Text] [Related]
22. Linac photon beam fine-tuning in PRIMO using the gamma-index analysis toolkit.
Bacala AM
Radiat Oncol; 2020 Jan; 15(1):8. PubMed ID: 31906977
[TBL] [Abstract][Full Text] [Related]
23. Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study.
Molazadeh M; Zeinali A; Robatjazi M; Shirazi A; Geraily G
J Appl Clin Med Phys; 2017 Mar; 18(2):113-124. PubMed ID: 28300380
[TBL] [Abstract][Full Text] [Related]
24. Monte Carlo modeling of Halcyon and Ethos radiotherapy beam using CAD geometry: validation and IAEA-compliant phase space.
Laakkonen L; Lehtomäki J; Cahill A; Constantin M; Kulmala A; Harju A
Phys Med Biol; 2023 Feb; 68(4):. PubMed ID: 36657172
[No Abstract] [Full Text] [Related]
25. Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.
Heath E; Seuntjens J
Phys Med Biol; 2003 Dec; 48(24):4045-63. PubMed ID: 14727750
[TBL] [Abstract][Full Text] [Related]
26. Monte carlo electron source model validation for an Elekta Precise linac.
Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
[TBL] [Abstract][Full Text] [Related]
27. Monte Carlo simulation of TrueBeam flattening-filter-free beams using varian phase-space files: comparison with experimental data.
Belosi MF; Rodriguez M; Fogliata A; Cozzi L; Sempau J; Clivio A; Nicolini G; Vanetti E; Krauss H; Khamphan C; Fenoglietto P; Puxeu J; Fedele D; Mancosu P; Brualla L
Med Phys; 2014 May; 41(5):051707. PubMed ID: 24784373
[TBL] [Abstract][Full Text] [Related]
28. An integrated Monte Carlo dosimetric verification system for radiotherapy treatment planning.
Yamamoto T; Mizowaki T; Miyabe Y; Takegawa H; Narita Y; Yano S; Nagata Y; Teshima T; Hiraoka M
Phys Med Biol; 2007 Apr; 52(7):1991-2008. PubMed ID: 17374923
[TBL] [Abstract][Full Text] [Related]
29. Monte Carlo modeling of a Novalis Tx Varian 6 MV with HD-120 multileaf collimator.
Vazquez-Quino LA; Massingill B; Shi C; Gutierrez A; Esquivel C; Eng T; Papanikolaou N; Stathakis S
J Appl Clin Med Phys; 2012 Sep; 13(5):3960. PubMed ID: 22955663
[TBL] [Abstract][Full Text] [Related]
30. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning.
Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ
Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343
[TBL] [Abstract][Full Text] [Related]
31. Dosimetric characteristics of electron beams produced by two mobile accelerators, Novac7 and Liac, for intraoperative radiation therapy through Monte Carlo simulation.
Righi S; Karaj E; Felici G; Di Martino F
J Appl Clin Med Phys; 2013 Jan; 14(1):3678. PubMed ID: 23318376
[TBL] [Abstract][Full Text] [Related]
32. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files.
Wijesooriya K; Aliotta E; Benedict S; Read P; Rich T; Larner J
Med Phys; 2012 Apr; 39(4):1846-53. PubMed ID: 22482606
[TBL] [Abstract][Full Text] [Related]
33. DeepBeam: a machine learning framework for tuning the primary electron beam of the PRIMO Monte Carlo software.
Tabor Z; Kabat D; Waligórski MPR
Radiat Oncol; 2021 Jun; 16(1):124. PubMed ID: 34187495
[TBL] [Abstract][Full Text] [Related]
34. New capabilities of the Monte Carlo dose engine ARCHER-RT: Clinical validation of the Varian TrueBeam machine for VMAT external beam radiotherapy.
Adam DP; Liu T; Caracappa PF; Bednarz BP; Xu XG
Med Phys; 2020 Jun; 47(6):2537-2549. PubMed ID: 32175615
[TBL] [Abstract][Full Text] [Related]
35. Monte Carlo simulation of linac using PRIMO.
Li Y; Sun X; Liang Y; Hu Y; Liu C
Radiat Oncol; 2022 Nov; 17(1):185. PubMed ID: 36384637
[TBL] [Abstract][Full Text] [Related]
36. An efficient framework for photon Monte Carlo treatment planning.
Fix MK; Manser P; Frei D; Volken W; Mini R; Born EJ
Phys Med Biol; 2007 Oct; 52(19):N425-37. PubMed ID: 17881793
[TBL] [Abstract][Full Text] [Related]
37. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
38. Comparison of monte carlo collimator transport methods for photon treatment planning in radiotherapy.
Schmidhalter D; Manser P; Frei D; Volken W; Fix MK
Med Phys; 2010 Feb; 37(2):492-504. PubMed ID: 20229858
[TBL] [Abstract][Full Text] [Related]
39. MLC leaf width impact on the clinical dose distribution: a Monte Carlo approach.
Leal A; Sánchez-Doblado F; Arráns R; Capote R; Lagares JI; Pavón EC; Roselló J
Int J Radiat Oncol Biol Phys; 2004 Aug; 59(5):1548-59. PubMed ID: 15275743
[TBL] [Abstract][Full Text] [Related]
40. Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.
Bednarz B; Xu XG
Phys Med Biol; 2009 Feb; 54(4):N43-57. PubMed ID: 19141879
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]