These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 24007090)
21. Impact of tissue heterogeneity on noninvasive near-infrared glucose measurements in interstitial fluid of rat skin. Alexeeva NV; Arnold MA J Diabetes Sci Technol; 2010 Sep; 4(5):1041-54. PubMed ID: 20920424 [TBL] [Abstract][Full Text] [Related]
22. Non-invasive blood glucose measurement by Fourier transform infrared spectroscopic analysis through the mucous membrane of the lip: application of a chalcogenide optical fiber system. Uemura T; Nishida K; Sakakida M; Ichinose K; Shimoda S; Shichiri M Front Med Biol Eng; 1999; 9(2):137-53. PubMed ID: 10450500 [TBL] [Abstract][Full Text] [Related]
23. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling. Sato T; Okada S; Hagino K; Asakura Y; Kikkawa Y; Kojima J; Watanabe T; Maekawa Y; Isobe K; Koike R; Nakajima H; Asano K Diabetes Technol Ther; 2011 Dec; 13(12):1194-200. PubMed ID: 21770766 [TBL] [Abstract][Full Text] [Related]
24. Progress and Perspectives of Mid-Infrared Photoacoustic Spectroscopy for Non-Invasive Glucose Detection. Kaysir MR; Song J; Rassel S; Aloraynan A; Ban D Biosensors (Basel); 2023 Jul; 13(7):. PubMed ID: 37504114 [TBL] [Abstract][Full Text] [Related]
25. Detection of aqueous glucose based on a cavity size- and optical-wavelength-independent continuous-wave photoacoustic technique. Camou S; Haga T; Tajima T; Tamechika E Anal Chem; 2012 Jun; 84(11):4718-24. PubMed ID: 22548281 [TBL] [Abstract][Full Text] [Related]
26. Spectroscopic quantitative analysis of blood glucose by Fourier transform infrared spectroscopy with an attenuated total reflection prism. Kajiwara K; Fukushima H; Kishikawa H; Nishida K; Hashiguchi Y; Sakakida M; Uehara M; Shichiri M Med Prog Technol; 1992; 18(3):181-9. PubMed ID: 1484514 [TBL] [Abstract][Full Text] [Related]
27. [In-Vivo Noninvasive Measurement of Human Blood Glucose Levels by Mid-Infrared Spectrograph with External CO(2) Laser Source]. Zhang QQ; Fan YL; He XQ; Sun YM Guang Pu Xue Yu Guang Pu Fen Xi; 2017 Jan; 37(1):85-8. PubMed ID: 30192485 [TBL] [Abstract][Full Text] [Related]
28. Tattoo-based noninvasive glucose monitoring: a proof-of-concept study. Bandodkar AJ; Jia W; Yardımcı C; Wang X; Ramirez J; Wang J Anal Chem; 2015 Jan; 87(1):394-8. PubMed ID: 25496376 [TBL] [Abstract][Full Text] [Related]
29. Microdialysis of interstitial fluid for continuous glucose measurement. Klonoff DC Diabetes Technol Ther; 2003; 5(4):539-43. PubMed ID: 14511409 [No Abstract] [Full Text] [Related]
30. Non-invasive blood glucose measurement of 95% certainty by pressure regulated Mid-IR. Chen JY; Zhou Q; Xu G; Wang RT; Tai EG; Xie L; Zhang Q; Guan Y; Huang X Talanta; 2019 May; 197():211-217. PubMed ID: 30771926 [TBL] [Abstract][Full Text] [Related]
31. Evaluation of the performance of a new OptiScanner™ 5000 system for an intermittent glucose monitoring. Barassi A; Umbrello M; Ghilardi F; Damele CA; Massaccesi L; Iapichino G; Melzi d'Eril GV Clin Chim Acta; 2015 Jan; 438():252-4. PubMed ID: 25218698 [TBL] [Abstract][Full Text] [Related]
32. New improvements in methane detection using a Helmholtz resonant photoacoustic laser sensor: a comparison between near-IR diode lasers and mid-IR quantum cascade lasers. Grossel A; Zeninari V; Joly L; Parvitte B; Courtois D; Durry G Spectrochim Acta A Mol Biomol Spectrosc; 2006 Apr; 63(5):1021-8. PubMed ID: 16500139 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system. Kuranuki S; Sato T; Okada S; Hosoya S; Seko A; Sugihara K; Nakamura T J Healthc Eng; 2013; 4(4):529-40. PubMed ID: 24287430 [TBL] [Abstract][Full Text] [Related]
34. Phase Difference Optimization of Dual-Wavelength Excitation for the CW-Photoacoustic-Based Noninvasive and Selective Investigation of Aqueous Solutions of Glucose. Camou S Sensors (Basel); 2015 Jul; 15(7):16358-71. PubMed ID: 26198230 [TBL] [Abstract][Full Text] [Related]
35. Validation of interstitial fluid continuous glucose monitoring in cystic fibrosis. Dobson L; Sheldon CD; Hattersley AT Diabetes Care; 2003 Jun; 26(6):1940-1. PubMed ID: 12766139 [No Abstract] [Full Text] [Related]
36. A Single Wavelength Mid-Infrared Photoacoustic Spectroscopy for Noninvasive Glucose Detection Using Machine Learning. Aloraynan A; Rassel S; Xu C; Ban D Biosensors (Basel); 2022 Mar; 12(3):. PubMed ID: 35323436 [TBL] [Abstract][Full Text] [Related]
37. In vivo measurement of glucose concentration with lasers. Müller A Horm Metab Res Suppl; 1979; (8):33-5. PubMed ID: 295039 [TBL] [Abstract][Full Text] [Related]
38. Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats. Woderer S; Henninger N; Garthe CD; Kloetzer HM; Hajnsek M; Kamecke U; Gretz N; Kraenzlin B; Pill J Anal Chim Acta; 2007 Jan; 581(1):7-12. PubMed ID: 17386418 [TBL] [Abstract][Full Text] [Related]
39. A new method to obtain Fourier transform infrared spectra free from water vapor disturbance. Chen Y; Wang HS; Umemura J Appl Spectrosc; 2010 Oct; 64(10):1186-9. PubMed ID: 20925991 [TBL] [Abstract][Full Text] [Related]