374 related articles for article (PubMed ID: 24007166)
1. Monitoring internal organ motion with continuous wave radar in CT.
Pfanner F; Maier J; Allmendinger T; Flohr T; Kachelrieß M
Med Phys; 2013 Sep; 40(9):091915. PubMed ID: 24007166
[TBL] [Abstract][Full Text] [Related]
2. Monitoring cardiac motion in CT using a continuous wave radar embedded in the patient table.
Pfanner F; Allmendinger T; Bohn B; Flohr T; Kachelrieß M
Med Phys; 2014 Aug; 41(8):081908. PubMed ID: 25086539
[TBL] [Abstract][Full Text] [Related]
3. A contactless approach for respiratory gating in PET using continuous-wave radar.
Ersepke T; Büther F; Heß M; Schäfers KP
Med Phys; 2015 Aug; 42(8):4911-9. PubMed ID: 26233217
[TBL] [Abstract][Full Text] [Related]
4. Linac-integrated 4D cone beam CT: first experimental results.
Dietrich L; Jetter S; Tücking T; Nill S; Oelfke U
Phys Med Biol; 2006 Jun; 51(11):2939-52. PubMed ID: 16723776
[TBL] [Abstract][Full Text] [Related]
5. Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation.
Coolens C; Bracken J; Driscoll B; Hope A; Jaffray D
Med Phys; 2012 May; 39(5):2669-81. PubMed ID: 22559637
[TBL] [Abstract][Full Text] [Related]
6. Prospective respiratory-gated micro-CT of free breathing rodents.
Ford NL; Nikolov HN; Norley CJ; Thornton MM; Foster PJ; Drangova M; Holdsworth DW
Med Phys; 2005 Sep; 32(9):2888-98. PubMed ID: 16266103
[TBL] [Abstract][Full Text] [Related]
7. 4D CT sorting based on patient internal anatomy.
Li R; Lewis JH; Cerviño LI; Jiang SB
Phys Med Biol; 2009 Aug; 54(15):4821-33. PubMed ID: 19622855
[TBL] [Abstract][Full Text] [Related]
8. The influence of respiratory motion on CT image volume definition.
Rodríguez-Romero R; Castro-Tejero P
Med Phys; 2014 Apr; 41(4):041701. PubMed ID: 24694121
[TBL] [Abstract][Full Text] [Related]
9. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: a digital phantom study.
Bernatowicz K; Keall P; Mishra P; Knopf A; Lomax A; Kipritidis J
Med Phys; 2015 Jan; 42(1):324-34. PubMed ID: 25563272
[TBL] [Abstract][Full Text] [Related]
10. Modeling respiratory motion for reducing motion artifacts in 4D CT images.
Zhang Y; Yang J; Zhang L; Court LE; Balter PA; Dong L
Med Phys; 2013 Apr; 40(4):041716. PubMed ID: 23556886
[TBL] [Abstract][Full Text] [Related]
11. An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing.
Ehrhardt J; Werner R; Säring D; Frenzel T; Lu W; Low D; Handels H
Med Phys; 2007 Feb; 34(2):711-21. PubMed ID: 17388189
[TBL] [Abstract][Full Text] [Related]
12. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom.
Yue Y; Fan Z; Yang W; Pang J; Deng Z; McKenzie E; Tuli R; Wallace R; Li D; Fraass B
Med Phys; 2015 Oct; 42(10):5787-97. PubMed ID: 26429253
[TBL] [Abstract][Full Text] [Related]
13. Patient specific respiratory motion modeling using a 3D patient's external surface.
Fayad H; Pan T; Pradier O; Visvikis D
Med Phys; 2012 Jun; 39(6):3386-95. PubMed ID: 22755719
[TBL] [Abstract][Full Text] [Related]
14. Respiratory correlated cone beam CT.
Sonke JJ; Zijp L; Remeijer P; van Herk M
Med Phys; 2005 Apr; 32(4):1176-86. PubMed ID: 15895601
[TBL] [Abstract][Full Text] [Related]
15. Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: a technical feasibility study.
Boye D; Lomax T; Knopf A
Med Phys; 2013 Jun; 40(6):061702. PubMed ID: 23718581
[TBL] [Abstract][Full Text] [Related]
16. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation.
Vedam S; Archambault L; Starkschall G; Mohan R; Beddar S
Med Phys; 2007 Nov; 34(11):4247-55. PubMed ID: 18072489
[TBL] [Abstract][Full Text] [Related]
17. A novel respiratory tracking system for smart-gated PET acquisition.
Nehmeh SA; Haj-Ali AA; Qing C; Stearns C; Kalaigian H; Kohlmyer S; Schoder H; Ho AY; Larson SM; Humm JL
Med Phys; 2011 Jan; 38(1):531-8. PubMed ID: 21361220
[TBL] [Abstract][Full Text] [Related]
18. The use of CT density changes at internal tissue interfaces to correlate internal organ motion with an external surrogate.
Gaede S; Carnes G; Yu E; Van Dyk J; Battista J; Lee TY
Phys Med Biol; 2009 Jan; 54(2):259-73. PubMed ID: 19088386
[TBL] [Abstract][Full Text] [Related]
19. Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking.
Berkels B; Bauer S; Ettl S; Arold O; Hornegger J; Rumpf M
Med Phys; 2013 Sep; 40(9):091703. PubMed ID: 24007136
[TBL] [Abstract][Full Text] [Related]
20. The effect of respiratory motion variability and tumor size on the accuracy of average intensity projection from four-dimensional computed tomography: an investigation based on dynamic MRI.
Cai J; Read PW; Sheng K
Med Phys; 2008 Nov; 35(11):4974-81. PubMed ID: 19070231
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]