353 related articles for article (PubMed ID: 2400800)
1. Electrochemistry of galvanic couples between carbon and common metallic biomaterials in the presence of crevices.
Silva RA; Barbosa MA; Jenkins GM; Sutherland I
Biomaterials; 1990 Jul; 11(5):336-40. PubMed ID: 2400800
[TBL] [Abstract][Full Text] [Related]
2. In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when galvanically coupled with carbon.
Thompson NG; Buchanan RA; Lemons JE
J Biomed Mater Res; 1979 Jan; 13(1):35-44. PubMed ID: 429383
[TBL] [Abstract][Full Text] [Related]
3. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
Serhan H; Slivka M; Albert T; Kwak SD
Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
[TBL] [Abstract][Full Text] [Related]
4. Studies of the corrosion susceptibility of metallic cement restrictors: comparative corrosion behavior of stainless steel and cobalt-chromium alloys.
Pugh J; Jaffe WL; Kummer FJ
Bull Hosp Joint Dis; 1976 Apr; 37(1):40-53. PubMed ID: 974288
[TBL] [Abstract][Full Text] [Related]
5. Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion.
Mueller Y; Tognini R; Mayer J; Virtanen S
J Biomed Mater Res A; 2007 Sep; 82(4):936-46. PubMed ID: 17335021
[TBL] [Abstract][Full Text] [Related]
6. Study of corrosion between a titanium implant and dental alloys.
Reclaru L; Meyer JM
J Dent; 1994 Jun; 22(3):159-68. PubMed ID: 8027459
[TBL] [Abstract][Full Text] [Related]
7. Electrochemical corrosion of metallic biomaterials.
Pourbaix M
Biomaterials; 1984 May; 5(3):122-34. PubMed ID: 6375748
[TBL] [Abstract][Full Text] [Related]
8. Corrosion of titanium/cobalt-chromium alloy couples.
Kummer FJ; Rose RM
J Bone Joint Surg Am; 1983 Oct; 65(8):1125-6. PubMed ID: 6630255
[TBL] [Abstract][Full Text] [Related]
9. The concept of protection potential applied to the corrosion of metallic orthopedic implants.
Cahoon JR; Bandyopadhya R; Tennese L
J Biomed Mater Res; 1975 May; 9(3):259-64. PubMed ID: 1176484
[TBL] [Abstract][Full Text] [Related]
10. Galvanic couples of 316L steel with Ti and ion plated Ti and TiN coatings in Ringer's solutions.
Gluszek J; Jedrkowiak J; Markowski J; Masalski J
Biomaterials; 1990 Jul; 11(5):330-5. PubMed ID: 2400799
[TBL] [Abstract][Full Text] [Related]
11. Metallic biomaterials TiN-coated: corrosion analysis and biocompatibility.
Paschoal AL; Vanâncio EC; Canale Lde C; da Silva OL; Huerta-Vilca D; Motheo Ade J
Artif Organs; 2003 May; 27(5):461-4. PubMed ID: 12752209
[TBL] [Abstract][Full Text] [Related]
12. In vitro crevice corrosion behavior of implant materials.
Sutow EJ; Jones DW; Milne EL
J Dent Res; 1985 May; 64(5):842-7. PubMed ID: 3858307
[TBL] [Abstract][Full Text] [Related]
13. Effects of fused-ring antibiotics on metallic corrosion.
von Fraunhofer JA; Stidham SH
J Biomed Eng; 1991 Sep; 13(5):424-8. PubMed ID: 1795511
[TBL] [Abstract][Full Text] [Related]
14. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material.
Reclaru L; Lerf R; Eschler PY; Blatter A; Meyer JM
Biomaterials; 2002 Aug; 23(16):3479-85. PubMed ID: 12099292
[TBL] [Abstract][Full Text] [Related]
15. Fretting initiated crevice corrosion of 316LVM stainless steel in physiological phosphate buffered saline: Potential and cycles to initiation.
Liu Y; Zhu D; Pierre D; Gilbert JL
Acta Biomater; 2019 Oct; 97():565-577. PubMed ID: 31374339
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of restorative and implant alloys galvanically coupled to titanium.
Venugopalan R; Lucas LC
Dent Mater; 1998 Jun; 14(3):165-72. PubMed ID: 10196792
[TBL] [Abstract][Full Text] [Related]
17. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
[TBL] [Abstract][Full Text] [Related]
18. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
[TBL] [Abstract][Full Text] [Related]
19. [Corrosion resistance of Ti-Cu alloy].
Song YX; Wang SM
Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):565-8. PubMed ID: 21122454
[TBL] [Abstract][Full Text] [Related]
20. In vivo evaluation of a high-strength, high-ductility stainless steel for use in surgical implants.
Syrett BC; Davis EE
J Biomed Mater Res; 1979 Jul; 13(4):543-56. PubMed ID: 110810
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]