BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

364 related articles for article (PubMed ID: 2400800)

  • 21. Tribocorrosion studies of metallic biomaterials: The effect of plasma nitriding and DLC surface modifications.
    Zhao GH; Aune RE; Espallargas N
    J Mech Behav Biomed Mater; 2016 Oct; 63():100-114. PubMed ID: 27348147
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Microstructure-dependent crevice corrosion damage of implant materials CoCr28Mo6, TiAl6V4 and REX 734 under severe inflammatory conditions.
    Herbster M; Rosemann P; Michael O; Harnisch K; Ecke M; Heyn A; Lohmann CH; Bertrand J; Halle T
    J Biomed Mater Res B Appl Biomater; 2022 Jul; 110(7):1687-1704. PubMed ID: 35174958
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions.
    López DA; Durán A; Ceré SM
    J Mater Sci Mater Med; 2008 May; 19(5):2137-44. PubMed ID: 17999036
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of metal release from various metallic biomaterials in vitro.
    Okazaki Y; Gotoh E
    Biomaterials; 2005 Jan; 26(1):11-21. PubMed ID: 15193877
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Toxicity measurement of orthopedic implant alloy degradation products using a bioluminescent bacterial assay.
    Shettlemore MG; Bundy KJ
    J Biomed Mater Res; 1999 Jun; 45(4):395-403. PubMed ID: 10321713
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In vitro effects of macrophages on orthopaedic implant alloys and local release of metallic alloy components.
    Heise G; Black CM; Smith R; Morrow BR; Mihalko WM
    Bone Joint J; 2020 Jul; 102-B(7_Supple_B):116-121. PubMed ID: 32600200
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of Ti-C:H coating and plasma nitriding treatment on tribological, electrochemical, and biocompatibility properties of AISI 316L.
    Kao WH; Su YL; Horng JH; Zhang KX
    J Biomater Appl; 2016 Aug; 31(2):215-29. PubMed ID: 27422714
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of mixed alloy combinations on fretting corrosion performance of spinal screw and rod implants.
    Mali SA; Singh V; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2017 Jul; 105(5):1169-1177. PubMed ID: 27038431
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tailoring Surface Hydrophilicity Property for Biomedical 316L and 304 Stainless Steels: A Special Perspective on Studying Osteoconductivity and Biocompatibility.
    Peng C; Izawa T; Zhu L; Kuroda K; Okido M
    ACS Appl Mater Interfaces; 2019 Dec; 11(49):45489-45497. PubMed ID: 31714730
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Corrosion and surface modification on biocompatible metals: A review.
    Asri RIM; Harun WSW; Samykano M; Lah NAC; Ghani SAC; Tarlochan F; Raza MR
    Mater Sci Eng C Mater Biol Appl; 2017 Aug; 77():1261-1274. PubMed ID: 28532004
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Characteristics of metals used in implants.
    Gotman I
    J Endourol; 1997 Dec; 11(6):383-9. PubMed ID: 9440845
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrochemical studies on the influence of proteins on the corrosion of implant alloys.
    Williams RL; Brown SA; Merritt K
    Biomaterials; 1988 Mar; 9(2):181-6. PubMed ID: 3370285
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Corrosion degradation and prevention by surface modification of biometallic materials.
    Singh R; Dahotre NB
    J Mater Sci Mater Med; 2007 May; 18(5):725-51. PubMed ID: 17143737
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Biodeterioration and corrosion of metallic implants and prostheses].
    López GD
    Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fretting corrosion in orthopaedic alloys.
    Cook SD; Gianoli GJ; Clemow AJ; Haddad RJ
    Biomater Med Devices Artif Organs; 1983-1984; 11(4):281-92. PubMed ID: 6679798
    [TBL] [Abstract][Full Text] [Related]  

  • 36. New generation super alloy candidates for medical applications: corrosion behavior, cation release and biological evaluation.
    Reclaru L; Ziegenhagen R; Unger RE; Eschler PY; Constantin F
    Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():411-20. PubMed ID: 25491846
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrical potentials between stent-grafts made from different metals induce negligible corrosion.
    Kazimierczak A; Podraza W; Lenart S; Wiernicki I; Gutowski P
    Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):432-7. PubMed ID: 23867322
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.
    Thierry B; Tabrizian M; Trepanier C; Savadogo O; Yahia L
    J Biomed Mater Res; 2000 Sep; 51(4):685-93. PubMed ID: 10880117
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Corrosion behaviour of AISI 316L stainless-steel alloys in diabetic serum.
    Moura e Silva T; Monteiro JM; Ferreira MG; Vieira JM
    Clin Mater; 1993; 12(2):103-6. PubMed ID: 10148337
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A new stainless steel alloy for surgical implants compared to 316 S12.
    Smethurst E
    Biomaterials; 1981 Apr; 2(2):116-9. PubMed ID: 7248423
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.