These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 24008462)

  • 21. Successful endoscopic removal of fractured guidewire fragments from a peripheral bile duct using a biliary stent delivery system and biopsy forceps.
    Nishikawa Y; Uza N; Yamauchi Y; Fukuda A; Ueda Y; Kodama Y; Seno H
    Endoscopy; 2018 Oct; 50(10):E279-E280. PubMed ID: 29969804
    [No Abstract]   [Full Text] [Related]  

  • 22. Ropeway-type bile duct biopsy forceps with a side slit for a guidewire.
    Tamada K; Higashizawa T; Tomiyama T; Wada S; Ohashi A; Satoh Y; Ido K; Sugano K
    Gastrointest Endosc; 2001 Jan; 53(1):89-92. PubMed ID: 11154498
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A novel method for endoscopic removal of a fractured hydrophilic guide wire from an intrahepatic bile duct.
    Liu F; Li F; Jin ZD; Zou DW; Li ZS
    Endoscopy; 2008 Sep; 40 Suppl 2():E269. PubMed ID: 19090463
    [No Abstract]   [Full Text] [Related]  

  • 24. Endoscopic removal of a proximally migrated biliary stent using a novel gooseneck snare: the "EndoCowboy".
    Inoue T; Kitano R; Kobayashi Y; Ishii N; Ito K; Yoneda M
    Endoscopy; 2017 Dec; 49(12):E321-E322. PubMed ID: 28992636
    [No Abstract]   [Full Text] [Related]  

  • 25. Usefulness of endoscopic retrograde biliary biopsy using large-capacity forceps for extrahepatic biliary strictures: a prospective randomized study.
    Ikeda M; Maetani I; Terada K; Ukita T; Tada T; Shigoka H; Omuta S; Takahashi K
    Endoscopy; 2010 Oct; 42(10):837-41. PubMed ID: 20886402
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Successful retrieval of an immovable pancreatic stent using a novel thin-tipped balloon catheter.
    Inoue T; Ishii N; Kobayashi Y; Ito K; Yoneda M
    Endoscopy; 2017 Jun; 49(6):E157-E159. PubMed ID: 28464203
    [No Abstract]   [Full Text] [Related]  

  • 27. "Locked" pancreatic duct-wire technique for biliary cannulation.
    Menon S; Fisher NC
    Gastrointest Endosc; 2010 Sep; 72(3):668; author reply 669. PubMed ID: 20801293
    [No Abstract]   [Full Text] [Related]  

  • 28. The "U-wire" technique during ERCP for easy guide wire passage through occluded uncovered metal stents.
    Liu F; Zhu JY; Li ZS
    Endoscopy; 2012; 44 Suppl 2 UCTN():E116. PubMed ID: 22477173
    [No Abstract]   [Full Text] [Related]  

  • 29. Endoscopic approach to the patient with bile duct injury.
    Baillie J
    Gastrointest Endosc Clin N Am; 2013 Apr; 23(2):461-72. PubMed ID: 23540970
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A new time-saving technique of inserting multiple biliary endoprostheses without fluoroscopy.
    Misra SP; Dwivedi M
    Endoscopy; 1997 Jan; 29(1):58. PubMed ID: 9083750
    [No Abstract]   [Full Text] [Related]  

  • 31. Successful removal of a migrated plastic stent using a new endoscopic sheath.
    Yamada M; Okamoto T; Sasahira N
    Endoscopy; 2023 Dec; 55(S 01):E1250-E1251. PubMed ID: 38092059
    [No Abstract]   [Full Text] [Related]  

  • 32. Open-biopsy-forceps technique for removing biliary metallic stents that have migrated distally and wedged transversely in the duodenum.
    Matsushita M; Uchida K; Okazaki K
    Endoscopy; 2007 Jun; 39(6):570. PubMed ID: 17554657
    [No Abstract]   [Full Text] [Related]  

  • 33. Delayed removal of a deeply migrated pigtail pancreatic stent in a normal pancreatic duct.
    Jung YK; Lee TH; Park SH; Choi HJ; Cha SW; Moon JH; Cho YD
    Endoscopy; 2015; 47 Suppl 1 UCTN():E106-8. PubMed ID: 25734806
    [No Abstract]   [Full Text] [Related]  

  • 34. [The "rendez-vous" maneuver as a technical option to access the bile ducts: case series report].
    Pereira-Graterol F; Venales-Barrios Y; Bousquet-Suárez J; Cáceres-Cauro A; Romero-Bravo C; Moreno-Rodríguez J; Rodríguez-Perero L
    Rev Gastroenterol Mex; 2012; 77(4):224-8. PubMed ID: 23153415
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Use of covered self-expandable metal stents for endoscopic management of benign biliary disease not related to stricture (with video).
    Akbar A; Irani S; Baron TH; Topazian M; Petersen BT; Gostout CJ; Levy MJ; Gan I; Gluck M; Ross A; Kozarek RA
    Gastrointest Endosc; 2012 Jul; 76(1):196-201. PubMed ID: 22726483
    [No Abstract]   [Full Text] [Related]  

  • 36. [Proximal migration of biliary prosthesis. Endoscopic extraction techniques].
    Alfredo G; Raúl A; Barinagarrementeria R; Gutiérrez-Bermúdez JA; Martínez-Burciaga J
    Rev Gastroenterol Mex; 2001; 66(1):22-6. PubMed ID: 11464625
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Removable fully covered self-expandable metal stents in the treatment of common bile duct strictures due to chronic pancreatitis: a case series.
    Cahen DL; Rauws EA; Gouma DJ; Fockens P; Bruno MJ
    Endoscopy; 2008 Aug; 40(8):697-700. PubMed ID: 18704837
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Biliary stent placement for postoperative benign bile duct stenosis: personal experience].
    Sciumè C; Geraci G; Pisello F; Facella T; Li Volsi F; Modica G
    Ann Ital Chir; 2006; 77(1):19-24; discussion 25. PubMed ID: 16910355
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Endoscopic management of postcholecystectomy bile duct strictures.
    Vitale GC; Tran TC; Davis BR; Vitale M; Vitale D; Larson G
    J Am Coll Surg; 2008 May; 206(5):918-23; discussion 924-5. PubMed ID: 18471723
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Revision of migrated self-expandable metal stent by the remOVE device.
    Chua T; Fukami N
    Endoscopy; 2018 Nov; 50(11):1129-1130. PubMed ID: 30107627
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.