BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

881 related articles for article (PubMed ID: 24012696)

  • 1. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.
    Marinova M; Artusi C; Brugnolo L; Antonelli G; Zaninotto M; Plebani M
    Clin Biochem; 2013 Nov; 46(16-17):1723-7. PubMed ID: 24012696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.
    Vogeser M; Spöhrer U
    Clin Chem Lab Med; 2006; 44(9):1126-30. PubMed ID: 16958608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust, high-throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus, and sirolimus in whole blood.
    Koster RA; Dijkers EC; Uges DR
    Ther Drug Monit; 2009 Feb; 31(1):116-25. PubMed ID: 19065123
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous determination of four immunosuppressants by means of high speed and robust on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry.
    Koal T; Deters M; Casetta B; Kaever V
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jun; 805(2):215-22. PubMed ID: 15135093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Two rapid ultra performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) methods with common sample pretreatment for therapeutic drug monitoring of immunosuppressants compared to immunoassay.
    Tszyrsznic W; Borowiec A; Pawlowska E; Jazwiec R; Zochowska D; Bartlomiejczyk I; Zegarska J; Paczek L; Dadlez M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jun; 928():9-15. PubMed ID: 23584041
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An automated sample preparation approach for routine liquid chromatography tandem-mass spectrometry measurement of the alcohol biomarkers phosphatidylethanol 16:0/18:1, 16:0/16:0 and 18:1/18:1.
    Casati S; Ravelli A; Angeli I; Durello R; Minoli M; Orioli M
    J Chromatogr A; 2019 Mar; 1589():1-9. PubMed ID: 30598290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-throughput LC-MS/MS method for monitoring sirolimus and everolimus in the routine clinical laboratory.
    Ivanova M; Artusi C; Polo G; Zaninotto M; Plebani M
    Clin Chem Lab Med; 2011 Jul; 49(7):1151-8. PubMed ID: 21574883
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A direct method for the measurement of everolimus and sirolimus in whole blood by LC-MS/MS using an isotopic everolimus internal standard.
    Morgan PE; Brown NW; Tredger JM
    Ther Drug Monit; 2014 Jun; 36(3):358-65. PubMed ID: 24305629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inclusion of MPA and in a rapid multi-drug LC-tandem mass spectrometric method for simultaneous determination of immunosuppressants.
    Ceglarek U; Casetta B; Lembcke J; Baumann S; Fiedler GM; Thiery J
    Clin Chim Acta; 2006 Nov; 373(1-2):168-71. PubMed ID: 16806142
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Procedure for determination of immunosuppressive drugs in whole blood with liquid chromatography-isotope dilution mass spectrometry.
    Molnár PM; Dux L; Reinauer H; Kress M; Akerboom T; Szederkényi E; Kaiser P
    Clin Lab; 2011; 57(11-12):983-92. PubMed ID: 22239031
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recent development in application of high performance liquid chromatography-tandem mass spectrometry in therapeutic drug monitoring of immunosuppressants.
    Yang Z; Wang S
    J Immunol Methods; 2008 Jul; 336(2):98-103. PubMed ID: 18547583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a novel commercial assay for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus by liquid chromatography-tandem mass spectrometric assay.
    Becker S; Thiery J; Ceglarek U
    Ther Drug Monit; 2013 Feb; 35(1):129-32. PubMed ID: 23188181
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A rapid, simple and sensitive liquid chromatography-tandem mass spectrometry method for routine clinical monitoring of tacrolimus with the Waters Masstrak™ immmunosuppressant kit.
    Guilhaumou R; Lacarelle B; Sampol-Manos E
    Methods Find Exp Clin Pharmacol; 2010 Dec; 32(10):737-43. PubMed ID: 21225010
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid and simultaneous determination of tacrolimus (FK506) and diltiazem in human whole blood by liquid chromatography-tandem mass spectrometry: application to a clinical drug-drug interaction study.
    Li JL; Wang XD; Wang CX; Fu Q; Liu LS; Huang M; Zhou SF
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(1):111-8. PubMed ID: 18417431
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-throughput analysis of everolimus (RAD001) and cyclosporin A (CsA) in whole blood by liquid chromatography/mass spectrometry using a semi-automated 96-well solid-phase extraction system.
    McMahon LM; Luo S; Hayes M; Tse FL
    Rapid Commun Mass Spectrom; 2000; 14(21):1965-71. PubMed ID: 11085405
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fast LC-MS/MS analysis of tacrolimus, sirolimus, everolimus and cyclosporin A in dried blood spots and the influence of the hematocrit and immunosuppressant concentration on recovery.
    Koster RA; Alffenaar JW; Greijdanus B; Uges DR
    Talanta; 2013 Oct; 115():47-54. PubMed ID: 24054560
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fast LC-MS/MS analysis of free oxysterols derived from reactive oxygen species in human plasma and carotid plaque.
    Helmschrodt C; Becker S; Schröter J; Hecht M; Aust G; Thiery J; Ceglarek U
    Clin Chim Acta; 2013 Oct; 425():3-8. PubMed ID: 23827692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of four immunosuppressive drugs in whole blood using MEPS and LC-MS/MS allowing automated sample work-up and analysis.
    Said R; Pohanka A; Abdel-Rehim M; Beck O
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 May; 897():42-9. PubMed ID: 22542514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS).
    Gómez-Ríos GA; Tascon M; Reyes-Garcés N; Boyacı E; Poole JJ; Pawliszyn J
    Anal Chim Acta; 2018 Jan; 999():69-75. PubMed ID: 29254576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a rapid micro-scale assay for tacrolimus by liquid chromatography-tandem mass spectrometry.
    Keevil BG; McCann SJ; Cooper DP; Morris MR
    Ann Clin Biochem; 2002 Sep; 39(Pt 5):487-92. PubMed ID: 12227855
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 45.