148 related articles for article (PubMed ID: 24014787)
1. Antibiotic-coated pins for prevention of pin-tract infection: a rabbit study.
Rahimnia AR; Abbaspour A; Rezaei Y; Khodadadi A; Alizadeh AM; Mohagheghi MA; Semeyari H; Imani Fooladi AA; Izadi M; Keshavarz P; Yasui N
J Orthop Surg (Hong Kong); 2013 Aug; 21(2):213-5. PubMed ID: 24014787
[TBL] [Abstract][Full Text] [Related]
2. Commentary: Antibiotic-coated pins for prevention of pin-tract infection: a rabbit study.
Johari AN; Maheshwari S
J Orthop Surg (Hong Kong); 2013 Aug; 21(2):140. PubMed ID: 24014769
[No Abstract] [Full Text] [Related]
3. Antimicrobial efficacy of external fixator pins coated with a lipid stabilized hydroxyapatite/chlorhexidine complex to prevent pin tract infection in a goat model.
DeJong ES; DeBerardino TM; Brooks DE; Nelson BJ; Campbell AA; Bottoni CR; Pusateri AE; Walton RS; Guymon CH; McManus AT
J Trauma; 2001 Jun; 50(6):1008-14. PubMed ID: 11426113
[TBL] [Abstract][Full Text] [Related]
4. Decreasing bacterial colonization of external fixation pins through nitric oxide release coatings.
Holt J; Hertzberg B; Weinhold P; Storm W; Schoenfisch M; Dahners L
J Orthop Trauma; 2011 Jul; 25(7):432-7. PubMed ID: 21637124
[TBL] [Abstract][Full Text] [Related]
5. Chitosan-based sleeves loaded with silver and chlorhexidine in a percutaneous rabbit tibia model with a repeated bacterial challenge.
Shao J; Wang B; Bartels CJM; Bronkhorst EM; Jansen JA; Walboomers XF; Yang F
Acta Biomater; 2018 Dec; 82():102-110. PubMed ID: 30342284
[TBL] [Abstract][Full Text] [Related]
6. Use of a tobramycin-impregnated polymethylmethacrylate pin sleeve for the prevention of pin-tract infection in goats.
Voos K; Rosenberg B; Fagrhi M; Seligson D
J Orthop Trauma; 1999 Feb; 13(2):98-101. PubMed ID: 10052783
[TBL] [Abstract][Full Text] [Related]
7. Pin tract infections: silver vs uncoated pins.
Collinge CA; Goll G; Seligson D; Easley KJ
Orthopedics; 1994 May; 17(5):445-8. PubMed ID: 8036188
[TBL] [Abstract][Full Text] [Related]
8. Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis : a randomized, controlled trial.
Pommer A; Muhr G; Dávid A
J Bone Joint Surg Am; 2002 Jul; 84(7):1162-6. PubMed ID: 12107316
[TBL] [Abstract][Full Text] [Related]
9. Prevalence of pin tract infection: the role of combined silver sulphadiazine and chlorhexidine dressing.
Ogbemudia AO; Bafor A; Edomwonyi E; Enemudo R
Niger J Clin Pract; 2010 Sep; 13(3):268-71. PubMed ID: 20857782
[TBL] [Abstract][Full Text] [Related]
10. Bactericidal micron-thin sol-gel films prevent pin tract and periprosthetic infection.
Qu H; Knabe C; Burke M; Radin S; Garino J; Schaer T; Ducheyne P
Mil Med; 2014 Aug; 179(8 Suppl):29-33. PubMed ID: 25102546
[TBL] [Abstract][Full Text] [Related]
11. Clinical and histomorphometrical study on titanium dioxide-coated external fixation pins.
Koseki H; Asahara T; Shida T; Yoda I; Horiuchi H; Baba K; Osaki M
Int J Nanomedicine; 2013; 8():593-9. PubMed ID: 23429667
[TBL] [Abstract][Full Text] [Related]
12. Carboxymethyl chitosan-zinc coating for prevention of pin tract infection: An animal model.
Martin VT; Wang L; Zeng R; You D; Zhang X; Elodie WH; Yu B
J Orthop Surg (Hong Kong); 2018; 26(1):2309499017749981. PubMed ID: 29343155
[TBL] [Abstract][Full Text] [Related]
13. Hydroxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature.
Pizà G; Caja VL; González-Viejo MA; Navarro A
J Bone Joint Surg Br; 2004 Aug; 86(6):892-7. PubMed ID: 15330032
[TBL] [Abstract][Full Text] [Related]
14. External fixator pin tract infection model in the caprine (goat) tibia: a randomized, prospective, blinded study.
Warme WJ; Brooks D; Carpenter L; McManus AT
Am J Orthop (Belle Mead NJ); 2004 Sep; 33(9):447-51. PubMed ID: 15509109
[TBL] [Abstract][Full Text] [Related]
15. State of the art review: techniques to avoid pin loosening and infection in external fixation.
Moroni A; Vannini F; Mosca M; Giannini S
J Orthop Trauma; 2002 Mar; 16(3):189-95. PubMed ID: 11880783
[TBL] [Abstract][Full Text] [Related]
16. Modulation of the soft tissue reactions to percutaneous orthopaedic implants.
Smith TJ; Galm A; Chatterjee S; Wells R; Pedersen S; Parizi AM; Goodship AE; Blunn GW
J Orthop Res; 2006 Jul; 24(7):1377-83. PubMed ID: 16732606
[TBL] [Abstract][Full Text] [Related]
17. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model.
van der Borden AJ; Maathuis PG; Engels E; Rakhorst G; van der Mei HC; Busscher HJ; Sharma PK
Biomaterials; 2007 Apr; 28(12):2122-6. PubMed ID: 17258314
[TBL] [Abstract][Full Text] [Related]
18. No clinical benefits using a new design of pins for external fixation: a randomized study in 50 patients operated on by the hemicallotasis technique.
W-Dahl A; Toksvig-Larsen S
Arch Orthop Trauma Surg; 2008 Jul; 128(7):661-7. PubMed ID: 17701189
[TBL] [Abstract][Full Text] [Related]
19. Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins.
Moroni A; Heikkila J; Magyar G; Toksvig-Larsen S; Giannini S
Clin Orthop Relat Res; 2001 Jul; (388):209-17. PubMed ID: 11451122
[TBL] [Abstract][Full Text] [Related]
20. Percutaneous external fixator pins with bactericidal micron-thin sol-gel films for the prevention of pin tract infection.
Qu H; Knabe C; Radin S; Garino J; Ducheyne P
Biomaterials; 2015 Sep; 62():95-105. PubMed ID: 26036176
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]