BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 24014787)

  • 21. Contamination of the medullary canal following pin-tract infection.
    Clasper JC; Parker SJ; Simpson AH; Watkins PE
    J Orthop Res; 1999 Nov; 17(6):947-52. PubMed ID: 10632463
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical, scanning electron microscopy, and microhardness analyses of the bone-pin interface in hydroxyapatite coated versus uncoated pins.
    Moroni A; Caja VL; Maltarello MC; Savarino L; Marinelli F; Stea S; Visentin M; Giannini S
    J Orthop Trauma; 1997 Apr; 11(3):154-61. PubMed ID: 9181496
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hydroxyapatite-coated external fixation pins.
    Moroni A; Pegreffi F; Cadossi M; Hoang-Kim A; Lio V; Giannini S
    Expert Rev Med Devices; 2005 Jul; 2(4):465-71. PubMed ID: 16293085
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The influence of hydroxyapatite coating of external fixator pins on pin loosening and pin track infection: a systematic review.
    Saithna A
    Injury; 2010 Feb; 41(2):128-32. PubMed ID: 19486974
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intrawound vancomycin powder eradicates surgical wound contamination: an in vivo rabbit study.
    Zebala LP; Chuntarapas T; Kelly MP; Talcott M; Greco S; Riew KD
    J Bone Joint Surg Am; 2014 Jan; 96(1):46-51. PubMed ID: 24382724
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pin site care in external fixation sodium chloride or chlorhexidine solution as a cleansing agent.
    W-Dahl A; Toksvig-Larsen S
    Arch Orthop Trauma Surg; 2004 Oct; 124(8):555-8. PubMed ID: 15338244
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prevention of infection in external fixator pin sites.
    Jennison T; McNally M; Pandit H
    Acta Biomater; 2014 Feb; 10(2):595-603. PubMed ID: 24076071
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of hydroxyapatite-coated and uncoated pins for transfixation casting in horses.
    Lescun TB; Baird DK; Oliver LJ; Adams SB; Hawkins JF; Moore GE
    Am J Vet Res; 2012 May; 73(5):724-34. PubMed ID: 22533407
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Prevention of pin tract infection with iodine-supported titanium pins.
    Shirai T; Watanabe K; Matsubara H; Nomura I; Fujiwara H; Arai Y; Ikoma K; Terauchi R; Kubo T; Tsuchiya H
    J Orthop Sci; 2014 Jul; 19(4):598-602. PubMed ID: 24687211
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Improving tribological and anti-bacterial properties of titanium external fixation pins through surface ceramic conversion.
    Dong H; Mukinay T; Li M; Hood R; Soo SL; Cockshott S; Sammons R; Li X
    J Mater Sci Mater Med; 2017 Jan; 28(1):5. PubMed ID: 27885572
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Characterization of Staphylococcus aureus strains in a rabbit model of osseointegrated pin infections.
    Williams D; Bloebaum R; Petti CA
    J Biomed Mater Res A; 2008 May; 85(2):366-70. PubMed ID: 17688277
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bactericidal activity of antimicrobial coated polyurethane sleeves for external fixation pins.
    Forster H; Marotta JS; Heseltine K; Milner R; Jani S
    J Orthop Res; 2004 May; 22(3):671-7. PubMed ID: 15099651
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fixation strength of tapered versus bicylindrical hydroxyapatite-coated external fixation pins: an animal study.
    Moroni A; Faldini C; Pegreffi F; Giannini S
    J Biomed Mater Res; 2002; 63(1):61-4. PubMed ID: 11787030
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Efficacy of bioabsorbable antibiotic containing bone screw in the prevention of biomaterial-related infection due to Staphylococcus aureus.
    Mäkinen TJ; Veiranto M; Knuuti J; Jalava J; Törmälä P; Aro HT
    Bone; 2005 Feb; 36(2):292-9. PubMed ID: 15780955
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external-fixation pins. A prospective, randomized clinical study of wrist fractures.
    Moroni A; Faldini C; Marchetti S; Manca M; Consoli V; Giannini S
    J Bone Joint Surg Am; 2001 May; 83(5):717-21. PubMed ID: 11379741
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of insertion characteristics of two types of hydroxyapatite-coated and uncoated positive profile transfixation pins in the third metacarpal bone of horses.
    Zacharias JR; Lescun TB; Moore GE; Van Sickle DC
    Am J Vet Res; 2007 Nov; 68(11):1160-6. PubMed ID: 17975969
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hydroxyapatite-coated compared with stainless steel external fixation pins did not show impact in the rate of pin track infection: a multicenter prospective study.
    Stoffel C; de Lima E; Salles MJ
    Int Orthop; 2023 May; 47(5):1163-1169. PubMed ID: 36773051
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Reduction of postoperative spinal implant infection using gentamicin microspheres.
    Stall AC; Becker E; Ludwig SC; Gelb D; Poelstra KA
    Spine (Phila Pa 1976); 2009 Mar; 34(5):479-83. PubMed ID: 19247168
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Factors in pin tract infections.
    Mahan J; Seligson D; Henry SL; Hynes P; Dobbins J
    Orthopedics; 1991 Mar; 14(3):305-8. PubMed ID: 2020629
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Spread of infection, in an animal model, after intramedullary nailing of an infected external fixator pin track.
    Clasper JC; Stapley SA; Bowley DM; Kenward CE; Taylor V; Watkins PE
    J Orthop Res; 2001 Jan; 19(1):155-9. PubMed ID: 11332613
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.