281 related articles for article (PubMed ID: 24027454)
21. Far cortical locking technology for fixation of periprosthetic distal femur fractures: a surgical technique.
Ries ZG; Marsh JL
J Knee Surg; 2013 Feb; 26(1):15-8. PubMed ID: 23408343
[TBL] [Abstract][Full Text] [Related]
22. Less invasive polyaxial locking plate fixation in periprosthetic and peri-implant fractures of the femur--a prospective study of 41 patients.
Ruchholtz S; El-Zayat B; Kreslo D; Bücking B; Lewan U; Krüger A; Zettl R
Injury; 2013 Feb; 44(2):239-48. PubMed ID: 23219240
[TBL] [Abstract][Full Text] [Related]
23. [Minimally invasive plate osteosynthesis of the distal femur].
Link BC; Rosenkranz J; Winkler J; Babst R
Oper Orthop Traumatol; 2012 Sep; 24(4-5):324-34. PubMed ID: 23064649
[TBL] [Abstract][Full Text] [Related]
24. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
[TBL] [Abstract][Full Text] [Related]
25. Clinical outcome of interprosthetic femoral fractures treated with polyaxial locking plates.
Hoffmann MF; Lotzien S; Schildhauer TA
Injury; 2016 Apr; 47(4):934-8. PubMed ID: 26792022
[TBL] [Abstract][Full Text] [Related]
26. The use of interfragmentary positional screw in minimally invasive plate osteosynthesis for simple distal femur fractures in elderly patients: A retrospective, single-centre pilot study.
Chung JY; Cho JH; Kweon HJ; Song HK
Injury; 2016 Dec; 47(12):2795-2799. PubMed ID: 27802890
[TBL] [Abstract][Full Text] [Related]
27. A double-plating approach to distal femur fracture: A clinical study.
Steinberg EL; Elis J; Steinberg Y; Salai M; Ben-Tov T
Injury; 2017 Oct; 48(10):2260-2265. PubMed ID: 28768571
[TBL] [Abstract][Full Text] [Related]
28. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
Lujan TJ; Henderson CE; Madey SM; Fitzpatrick DC; Marsh JL; Bottlang M
J Orthop Trauma; 2010 Mar; 24(3):156-62. PubMed ID: 20182251
[TBL] [Abstract][Full Text] [Related]
29. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
[TBL] [Abstract][Full Text] [Related]
30. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
[TBL] [Abstract][Full Text] [Related]
31. Endosteal substitution with medial plate in the treatment of acute distal femur fracture (AO/OTA type A): surgical technique and case-series.
Al Farii H; Cloutier JP; AlQahtani S; Kreder H; Mutch J
Eur J Orthop Surg Traumatol; 2022 Feb; 32(2):211-217. PubMed ID: 33779830
[TBL] [Abstract][Full Text] [Related]
32. Early peri-implant fractures after distal femur fracture locked plating?
Meyer AP; Large TM
Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):2081-2089. PubMed ID: 36201033
[TBL] [Abstract][Full Text] [Related]
33. Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures.
Apivatthakakul T; Phornphutkul C; Bunmaprasert T; Sananpanich K; Fernandez Dell'Oca A
Arch Orthop Trauma Surg; 2012 Jun; 132(6):813-22. PubMed ID: 22389063
[TBL] [Abstract][Full Text] [Related]
34. Locking compression plate versus revision-prosthesis for Vancouver type B2 periprosthetic femoral fractures after total hip arthroplasty.
Joestl J; Hofbauer M; Lang N; Tiefenboeck T; Hajdu S
Injury; 2016 Apr; 47(4):939-43. PubMed ID: 26872997
[TBL] [Abstract][Full Text] [Related]
35. Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.
Henderson CE; Bottlang M; Marsh JL; Fitzpatrick DC; Madey SM
Iowa Orthop J; 2008; 28():73-6. PubMed ID: 19223952
[TBL] [Abstract][Full Text] [Related]
36. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
[TBL] [Abstract][Full Text] [Related]
37. Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up.
Xue H; Tu Y; Cai M; Yang A
J Arthroplasty; 2011 Apr; 26(3):467-471.e1. PubMed ID: 20570098
[TBL] [Abstract][Full Text] [Related]
38. Proximal Femur Peri-Implant Fracture After Lateral Femur Locking Plate: A Report of 2 Cases.
Meshay IM; Martin JR; Auran RL; Jones CB
JBJS Case Connect; 2020; 10(3):e19.00622-6. PubMed ID: 32668138
[TBL] [Abstract][Full Text] [Related]
39. Reversed Contralateral LISS Plate for Vancouver B1 Periprosthetic Femoral Shaft Fractures.
Russo M; Malekzadeh AS; Hampton C; Hymes R; Schwartzbach C; Schulman J
Orthopedics; 2015 Jun; 38(6):e467-72. PubMed ID: 26091218
[TBL] [Abstract][Full Text] [Related]
40. Minimally invasive double-plating osteosynthesis of the distal femur.
Beeres FJP; Emmink BL; Lanter K; Link BC; Babst R
Oper Orthop Traumatol; 2020 Dec; 32(6):545-558. PubMed ID: 32548732
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]