272 related articles for article (PubMed ID: 24027454)
41. Efficacy of Far Cortical Locking Screws in Treating Distal Tibia Fractures in Comparison With That of Standard Locking Screws.
Lee DO; Kang HW; Kim DY; Park GY; Hwang IU; Lee DY
J Foot Ankle Surg; 2023; 62(3):422-425. PubMed ID: 36404255
[TBL] [Abstract][Full Text] [Related]
42. Radiographic and Clinical Outcomes of Periprosthetic Distal Femur Fractures Treated With Open Reduction Internal Fixation.
Christ AB; Chawla H; Gausden EB; Villa JC; Wellman DS; Lorich DG; Helfet DL
J Orthop Trauma; 2018 Oct; 32(10):515-520. PubMed ID: 30247279
[TBL] [Abstract][Full Text] [Related]
43. Outcome of periprosthetic femoral fractures following total hip replacement treated with polyaxial locking plate.
Hoffmann MF; Lotzien S; Schildhauer TA
Eur J Orthop Surg Traumatol; 2017 Jan; 27(1):107-112. PubMed ID: 27600334
[TBL] [Abstract][Full Text] [Related]
44. [Treatment of Periprosthetic Distal Femoral Fractures].
Malotí T; Jansová M; Matějka T; Matějka J
Acta Chir Orthop Traumatol Cech; 2019; 86(3):205-211. PubMed ID: 31333185
[TBL] [Abstract][Full Text] [Related]
45. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
[TBL] [Abstract][Full Text] [Related]
46. Orthogonal plating of Vancouver B1 and C-type periprosthetic femur fracture nonunions.
Birch CE; Blankstein M; Chlebeck JD; Bartlett Rd CS
Hip Int; 2017 Nov; 27(6):578-583. PubMed ID: 28574123
[TBL] [Abstract][Full Text] [Related]
47. High complication rate in locking plate fixation of lower periprosthetic distal femur fractures in patients with total knee arthroplasties.
Ebraheim NA; Liu J; Hashmi SZ; Sochacki KR; Moral MZ; Hirschfeld AG
J Arthroplasty; 2012 May; 27(5):809-13. PubMed ID: 21964235
[TBL] [Abstract][Full Text] [Related]
48. Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study.
Moazen M; Leonidou A; Pagkalos J; Marghoub A; Fagan MJ; Tsiridis E
J Arthroplasty; 2016 Aug; 31(8):1849-56. PubMed ID: 26989031
[TBL] [Abstract][Full Text] [Related]
49. Any Cortical Bridging Predicts Healing of Supracondylar Femur Fractures After Treatment With Locked Plating.
Strotman PK; Karunakar MA; Seymour R; Lack WD
J Orthop Trauma; 2017 Oct; 31(10):538-544. PubMed ID: 28538286
[TBL] [Abstract][Full Text] [Related]
50. Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fractures.
Kim MB; Cho JW; Lee YH; Shon WY; Park JW; Kim J; Oh JK
Arch Orthop Trauma Surg; 2017 Sep; 137(9):1193-1200. PubMed ID: 28689273
[TBL] [Abstract][Full Text] [Related]
51. [Limited open reduction and double plates internal fixation for treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty].
Zhang Y; Fan X; Liu Y; Shao J; Tang J; Liu S; Yang T; Zhang C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1428-31. PubMed ID: 24640358
[TBL] [Abstract][Full Text] [Related]
52. Minimally invasive plate osteosynthesis with dual plating for periprosthetic distal femoral fractures following total knee arthroplasty.
Park YG; Kang H; Song JK; Lee J; Rho JY; Choi S
J Orthop Surg Res; 2021 Jul; 16(1):433. PubMed ID: 34229703
[TBL] [Abstract][Full Text] [Related]
53. Biomechanical optimization of the far cortical locking technique for early healing of distal femur fractures.
Sarwar A; Gee A; Bougherara H; Kuzyk PRT; Schemitsch EH; Zdero R
Med Eng Phys; 2021 Mar; 89():63-72. PubMed ID: 33608126
[TBL] [Abstract][Full Text] [Related]
54. [Plate osteosynthesis in vancouver type b1 and b2 periprosthetic fractures].
Fousek J; Vasek P
Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):410-6. PubMed ID: 19912706
[TBL] [Abstract][Full Text] [Related]
55. Periprosthetic Distal Femur Fracture after Total Knee Arthroplasty: A Systematic Review.
Ebraheim NA; Kelley LH; Liu X; Thomas IS; Steiner RB; Liu J
Orthop Surg; 2015 Nov; 7(4):297-305. PubMed ID: 26790831
[TBL] [Abstract][Full Text] [Related]
56. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.
Madey SM; Tsai S; Fitzpatrick DC; Earley K; Lutsch M; Bottlang M
Iowa Orthop J; 2017; 37():1-10. PubMed ID: 28852327
[TBL] [Abstract][Full Text] [Related]
57. Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis.
Shin YS; Kim HJ; Lee DH
Knee Surg Sports Traumatol Arthrosc; 2017 Sep; 25(9):2921-2928. PubMed ID: 26897137
[TBL] [Abstract][Full Text] [Related]
58. Modified fixations for distal femur fractures following total knee arthroplasty: a biomechanical and clinical relevance study.
Chen SH; Tai CL; Yu TC; Wang CW; Lin CW; Chen CY; Liu KC
Knee Surg Sports Traumatol Arthrosc; 2016 Oct; 24(10):3262-3271. PubMed ID: 27056688
[TBL] [Abstract][Full Text] [Related]
59. Osteosynthesis of periprosthetic type A and B femoral fractures using an unlocked plate with integrated cerclage cable and trochanteric hook: A multicenter retrospective study of 45 patients with mean follow-up of 20 months.
Gavanier B; Houfani F; Dumoulin Q; Bernard E; Mangin M; Mainard D
Injury; 2017 Dec; 48(12):2827-2832. PubMed ID: 29100663
[TBL] [Abstract][Full Text] [Related]
60. Locked plating of periprosthetic femur fractures above total knee arthroplasty.
Hou Z; Bowen TR; Irgit K; Strohecker K; Matzko ME; Widmaier J; Smith WR
J Orthop Trauma; 2012 Jul; 26(7):427-32. PubMed ID: 22357080
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]