BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 24034212)

  • 21. Validation of a deformable image registration technique for cone beam CT-based dose verification.
    Moteabbed M; Sharp GC; Wang Y; Trofimov A; Efstathiou JA; Lu HM
    Med Phys; 2015 Jan; 42(1):196-205. PubMed ID: 25563260
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Investigation of the usability of conebeam CT data sets for dose calculation.
    Richter A; Hu Q; Steglich D; Baier K; Wilbert J; Guckenberger M; Flentje M
    Radiat Oncol; 2008 Dec; 3():42. PubMed ID: 19087250
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Practically acquired and modified cone-beam computed tomography images for accurate dose calculation in head and neck cancer.
    Hu CC; Huang WT; Tsai CL; Wu JK; Chao HL; Huang GM; Wang CW; Wu CJ; Cheng JC
    Strahlenther Onkol; 2011 Oct; 187(10):633-44. PubMed ID: 21947125
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Patient-specific calibration of cone-beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment.
    MacFarlane M; Wong D; Hoover DA; Wong E; Johnson C; Battista JJ; Chen JZ
    J Appl Clin Med Phys; 2018 Mar; 19(2):249-257. PubMed ID: 29479821
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations.
    Held M; Sneed PK; Fogh SE; Pouliot J; Morin O
    J Appl Clin Med Phys; 2015 Nov; 16(6):458-471. PubMed ID: 26699575
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of air mapping errors on the dosimetric accuracy of prostate CBCT-guided online adaptive radiation therapy.
    Lemus OMD; Tanny S; Cummings M; Webster M; Wancura J; Jung H; Zhou Y; Yoon J; Pacella M; Zheng D
    J Appl Clin Med Phys; 2023 Oct; 24(10):e14057. PubMed ID: 37276082
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Application of image-guided radiotherapy in external beam radiation of cancer patients].
    Major T; Agoston P; Jorgo K; Polgár C
    Magy Onkol; 2012 Dec; 56(4):258-65. PubMed ID: 23236596
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.
    Disher B; Hajdok G; Wang A; Craig J; Gaede S; Battista JJ
    Phys Med Biol; 2013 Jun; 58(12):4157-74. PubMed ID: 23689060
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup.
    Mankinen M; Virén T; Seppälä J; Koivumäki T
    Radiat Oncol; 2024 Feb; 19(1):21. PubMed ID: 38347554
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dosimetric assessment of patient dose calculation on a deep learning-based synthesized computed tomography image for adaptive radiotherapy.
    Lemus OMD; Wang YF; Li F; Jambawalikar S; Horowitz DP; Xu Y; Wuu CS
    J Appl Clin Med Phys; 2022 Jul; 23(7):e13595. PubMed ID: 35332646
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Automated planning of breast radiotherapy using cone beam CT imaging.
    Amit G; Purdie TG
    Med Phys; 2015 Feb; 42(2):770-9. PubMed ID: 25652491
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging.
    Sarkar B; Ganesh T; Munshi A; Manikandan A; Roy S; Krishnankutty S; Chitral L; Sathiya J; Pradhan A; Mohanti BK
    Radiol Med; 2021 Jul; 126(7):979-988. PubMed ID: 33900527
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Daily dose evaluation based on corrected CBCTs for breast cancer patients: accuracy of dose and complication risk assessment.
    Hamming VC; Andersson S; Maduro JH; Langendijk JA; Both S; Sijtsema NM
    Radiat Oncol; 2022 Dec; 17(1):205. PubMed ID: 36510254
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of on-board kV cone beam computed tomography-based dose calculation with deformable image registration using Hounsfield unit modifications.
    Onozato Y; Kadoya N; Fujita Y; Arai K; Dobashi S; Takeda K; Kishi K; Umezawa R; Matsushita H; Jingu K
    Int J Radiat Oncol Biol Phys; 2014 Jun; 89(2):416-23. PubMed ID: 24685445
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Actual target coverage after setup verification using surgical clips compared with external skin markers in postoperative breast cancer radiation therapy.
    van der Salm A; Murrer L; Steenbakkers I; Houben R; Boersma LJ
    Pract Radiat Oncol; 2017; 7(6):e369-e376. PubMed ID: 28666904
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections.
    Zhang Y; Yin FF; Ren L
    Med Phys; 2015 Aug; 42(8):4783-95. PubMed ID: 26233206
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: results of a prospective study using cone-beam computed tomography.
    Fatunase T; Wang Z; Yoo S; Hubbs JL; Prosnitz RG; Yin FF; Marks LB
    Int J Radiat Oncol Biol Phys; 2008 Mar; 70(4):1025-34. PubMed ID: 17892919
    [TBL] [Abstract][Full Text] [Related]  

  • 38. 4D liver tumor localization using cone-beam projections and a biomechanical model.
    Zhang Y; Folkert MR; Li B; Huang X; Meyer JJ; Chiu T; Lee P; Tehrani JN; Cai J; Parsons D; Jia X; Wang J
    Radiother Oncol; 2019 Apr; 133():183-192. PubMed ID: 30448003
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images.
    Niu T; Sun M; Star-Lack J; Gao H; Fan Q; Zhu L
    Med Phys; 2010 Oct; 37(10):5395-406. PubMed ID: 21089775
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dosimetric impact of online correction via cone-beam CT-based image guidance for stereotactic lung radiotherapy.
    Galerani AP; Grills I; Hugo G; Kestin L; Mohammed N; Chao KK; Suen A; Martinez A; Yan D
    Int J Radiat Oncol Biol Phys; 2010 Dec; 78(5):1571-8. PubMed ID: 20646857
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.