153 related articles for article (PubMed ID: 24034216)
1. Fabrication of lactate biosensor based on lactate dehydrogenase immobilized on cerium oxide nanoparticles.
Nesakumar N; Sethuraman S; Krishnan UM; Rayappan JB
J Colloid Interface Sci; 2013 Nov; 410():158-64. PubMed ID: 24034216
[TBL] [Abstract][Full Text] [Related]
2. Low potential detection of NADH based on Fe₃O₄ nanoparticles/multiwalled carbon nanotubes composite: fabrication of integrated dehydrogenase-based lactate biosensor.
Teymourian H; Salimi A; Hallaj R
Biosens Bioelectron; 2012 Mar; 33(1):60-8. PubMed ID: 22230696
[TBL] [Abstract][Full Text] [Related]
3. A lactate biosensor based on lactate dehydrogenase/nictotinamide adenine dinucleotide (oxidized form) immobilized on a conducting polymer/multiwall carbon nanotube composite film.
Rahman MM; Shiddiky MJ; Rahman MA; Shim YB
Anal Biochem; 2009 Jan; 384(1):159-65. PubMed ID: 18851940
[TBL] [Abstract][Full Text] [Related]
4. The promotion effect of titania nanoparticles on the direct electrochemistry of lactate dehydrogenase sol-gel modified gold electrode.
Cheng J; Di J; Hong J; Yao K; Sun Y; Zhuang J; Xu Q; Zheng H; Bi S
Talanta; 2008 Sep; 76(5):1065-9. PubMed ID: 18761156
[TBL] [Abstract][Full Text] [Related]
5. An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides.
Chauhan N; Pundir CS
Anal Chim Acta; 2011 Sep; 701(1):66-74. PubMed ID: 21763810
[TBL] [Abstract][Full Text] [Related]
6. Fabrication of a highly sensitive electrochemiluminescence lactate biosensor using ZnO nanoparticles decorated multiwalled carbon nanotubes.
Haghighi B; Bozorgzadeh S
Talanta; 2011 Sep; 85(4):2189-93. PubMed ID: 21872077
[TBL] [Abstract][Full Text] [Related]
7. Electrochemical behavior of lactate dehydrogenase immobilized on "silica sol-gel/nanometre-sized tridecameric aluminum polycation" modified gold electrode and its application.
Cheng J; Huang D; Zhang J; Yang W; Wang N; Sun Y; Wang K; Mo X; Bi S
Analyst; 2009 Jul; 134(7):1392-5. PubMed ID: 19562207
[TBL] [Abstract][Full Text] [Related]
8. Construction and application of an amperometric xanthine biosensor based on zinc oxide nanoparticles-polypyrrole composite film.
Devi R; Thakur M; Pundir CS
Biosens Bioelectron; 2011 Apr; 26(8):3420-6. PubMed ID: 21324666
[TBL] [Abstract][Full Text] [Related]
9. Thermostable amperometric lactate biosensor with Clostridium thermocellum L-LDH for the measurement of blood lactate.
Ozkan M; Erhan E; Terzi O; Tan I; Ozöner SK
Talanta; 2009 Oct; 79(5):1412-7. PubMed ID: 19635378
[TBL] [Abstract][Full Text] [Related]
10. Direct electrochemistry of lactate dehydrogenase immobilized on silica sol-gel modified gold electrode and its application.
Di J; Cheng J; Xu Q; Zheng H; Zhuang J; Sun Y; Wang K; Mo X; Bi S
Biosens Bioelectron; 2007 Dec; 23(5):682-7. PubMed ID: 17869089
[TBL] [Abstract][Full Text] [Related]
11. Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide.
Lin CL; Shih CL; Chau LK
Anal Chem; 2007 May; 79(10):3757-63. PubMed ID: 17417817
[TBL] [Abstract][Full Text] [Related]
12. Polymeric FAD used as enzyme-friendly mediator in lactate detection.
Leonida MD; Starczynowski DT; Waldman R; Aurian-Blajeni B
Anal Bioanal Chem; 2003 Jul; 376(6):832-7. PubMed ID: 12811450
[TBL] [Abstract][Full Text] [Related]
13. An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode.
Rawal R; Chawla S; Malik P; Pundir CS
Int J Biol Macromol; 2012; 51(1-2):175-81. PubMed ID: 22142791
[TBL] [Abstract][Full Text] [Related]
14. An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode.
Rawal R; Chawla S; Pundir CS
Biosens Bioelectron; 2012 Jan; 31(1):144-50. PubMed ID: 22035973
[TBL] [Abstract][Full Text] [Related]
15. Enzymatic glucose biosensor based on CeO2 nanorods synthesized by non-isothermal precipitation.
Patil D; Dung NQ; Jung H; Ahn SY; Jang DM; Kim D
Biosens Bioelectron; 2012 Jan; 31(1):176-81. PubMed ID: 22035972
[TBL] [Abstract][Full Text] [Related]
16. Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film.
Ansari AA; Solanki PR; Malhotra BD
J Biotechnol; 2009 Jun; 142(2):179-84. PubMed ID: 19393698
[TBL] [Abstract][Full Text] [Related]
17. Construction of amperometric uric acid biosensor based on uricase immobilized on PBNPs/cMWCNT/PANI/Au composite.
Rawal R; Chawla S; Chauhan N; Dahiya T; Pundir CS
Int J Biol Macromol; 2012 Jan; 50(1):112-8. PubMed ID: 22020190
[TBL] [Abstract][Full Text] [Related]
18. Single-crystal CeO2 nanocubes used for the direct electron transfer and electrocatalysis of horseradish peroxidase.
Xiao X; Luan Q; Yao X; Zhou K
Biosens Bioelectron; 2009 Apr; 24(8):2447-51. PubMed ID: 19168345
[TBL] [Abstract][Full Text] [Related]
19. Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensor.
Khan R; Kaushik A; Solanki PR; Ansari AA; Pandey MK; Malhotra BD
Anal Chim Acta; 2008 Jun; 616(2):207-13. PubMed ID: 18482605
[TBL] [Abstract][Full Text] [Related]
20. Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+.
Piano M; Serban S; Pittson R; Drago GA; Hart JP
Talanta; 2010 Jun; 82(1):34-7. PubMed ID: 20685431
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]