These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

381 related articles for article (PubMed ID: 24036436)

  • 41. A high-performance glucose biosensor using covalently immobilised glucose oxidase on a poly(2,6-diaminopyridine)/carbon nanotube electrode.
    Ali Kamyabi M; Hajari N; Turner AP; Tiwari A
    Talanta; 2013 Nov; 116():801-8. PubMed ID: 24148477
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Advances in carbon nanotube based electrochemical sensors for bioanalytical applications.
    Vashist SK; Zheng D; Al-Rubeaan K; Luong JH; Sheu FS
    Biotechnol Adv; 2011; 29(2):169-88. PubMed ID: 21034805
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Layer-by-layer self-assembled multilayer films of carbon nanotubes and platinum nanoparticles with polyelectrolyte for the fabrication of biosensors.
    Yang M; Yang Y; Yang H; Shen G; Yu R
    Biomaterials; 2006 Jan; 27(2):246-55. PubMed ID: 16026820
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Porous platinum nanotubes modified with dendrimers as nanocarriers and electrocatalysts for sensitive electrochemical aptasensors based on enzymatic signal amplification.
    Xu W; Wu Y; Yi H; Bai L; Chai Y; Yuan R
    Chem Commun (Camb); 2014 Feb; 50(12):1451-3. PubMed ID: 24351980
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Ultrasensitive biosensor for detection of organophosphorus pesticides based on a macrocycle complex/carbon nanotubes composite and 1-methyl-3-octylimidazolium tetrafluoroborate as binder compound.
    Pereira Nd; de Oliveira FM; Pereira NR; Verly RM; Souto DE; Kubota LT; Tanaka AA; Damos FS; Luz Rde C
    Anal Sci; 2015; 31(1):29-35. PubMed ID: 25792271
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Site-specific immobilization of a (His)6-tagged acetylcholinesterase on nickel nanoparticles for highly sensitive toxicity biosensors.
    Ganesana M; Istarnboulie G; Marty JL; Noguer T; Andreescu S
    Biosens Bioelectron; 2011 Dec; 30(1):43-8. PubMed ID: 21937214
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Attachment of gold nanoparticles to glassy carbon electrode and its application for the direct electrochemistry and electrocatalytic behavior of hemoglobin.
    Zhang L; Jiang X; Wang E; Dong S
    Biosens Bioelectron; 2005 Aug; 21(2):337-45. PubMed ID: 16023961
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A novel amperometric biosensor based on covalently attached multilayer assemblies of gold nanoparticles, diazo-resins and acetylcholinesterase for the detection of organophosphorus pesticides.
    Jiang B; Dong P; Zheng J
    Talanta; 2018 Jun; 183():114-121. PubMed ID: 29567153
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A novel automated flow-based biosensor for the determination of organophosphate pesticides in milk.
    Mishra RK; Dominguez RB; Bhand S; Muñoz R; Marty JL
    Biosens Bioelectron; 2012 Feb; 32(1):56-61. PubMed ID: 22221795
    [TBL] [Abstract][Full Text] [Related]  

  • 50. An enhanced biosensor for glutamate based on self-assembled carbon nanotubes and dendrimer-encapsulated platinum nanobiocomposites-doped polypyrrole film.
    Tang L; Zhu Y; Yang X; Li C
    Anal Chim Acta; 2007 Jul; 597(1):145-50. PubMed ID: 17658324
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A novel nonenzymatic hydrogen peroxide sensor based on multi-wall carbon nanotube/silver nanoparticle nanohybrids modified gold electrode.
    Zhao W; Wang H; Qin X; Wang X; Zhao Z; Miao Z; Chen L; Shan M; Fang Y; Chen Q
    Talanta; 2009 Dec; 80(2):1029-33. PubMed ID: 19836592
    [TBL] [Abstract][Full Text] [Related]  

  • 52. D-fructose detection based on the direct heterogeneous electron transfer reaction of fructose dehydrogenase adsorbed onto multi-walled carbon nanotubes synthesized on platinum electrode.
    Tominaga M; Nomura S; Taniguchi I
    Biosens Bioelectron; 2009 Jan; 24(5):1184-8. PubMed ID: 18707862
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized on DNA functionalized carbon nanotubes.
    Zeng X; Li X; Liu X; Liu Y; Luo S; Kong B; Yang S; Wei W
    Biosens Bioelectron; 2009 Dec; 25(4):896-900. PubMed ID: 19783423
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A silk derived carbon fiber mat modified with Au@Pt urchilike nanoparticles: A new platform as electrochemical microbial biosensor.
    Deng L; Guo S; Zhou M; Liu L; Liu C; Dong S
    Biosens Bioelectron; 2010 Jun; 25(10):2189-93. PubMed ID: 20409699
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Indirect electrocatalytic determination of choline by monitoring hydrogen peroxide at the choline oxidase-prussian blue modified iron phosphate nanostructures.
    Zhang H; Yin Y; Wu P; Cai C
    Biosens Bioelectron; 2012 Jan; 31(1):244-50. PubMed ID: 22119562
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A novel layer-by-layer assembled multi-enzyme/CNT biosensor for discriminative detection between organophosphorus and non-organophosphrus pesticides.
    Zhang Y; Arugula MA; Wales M; Wild J; Simonian AL
    Biosens Bioelectron; 2015 May; 67():287-95. PubMed ID: 25192873
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Horseradish peroxidase-functionalized gold nanoparticle label for amplified immunoanalysis based on gold nanoparticles/carbon nanotubes hybrids modified biosensor.
    Cui R; Huang H; Yin Z; Gao D; Zhu JJ
    Biosens Bioelectron; 2008 Jun; 23(11):1666-73. PubMed ID: 18359217
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Highly sensitive and rapid detection of acetylcholine using an ITO plate modified with platinum-graphene nanoparticles.
    Chauhan N; Narang J; Jain U
    Analyst; 2015 Mar; 140(6):1988-94. PubMed ID: 25674632
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Highly sensitive and selective glutamate microbiosensor based on cast polyurethane/AC-electrophoresis deposited multiwalled carbon nanotubes and then glutamate oxidase/electrosynthesized polypyrrole/Pt electrode.
    Ammam M; Fransaer J
    Biosens Bioelectron; 2010 Mar; 25(7):1597-602. PubMed ID: 20034783
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.
    Salimi A; Compton RG; Hallaj R
    Anal Biochem; 2004 Oct; 333(1):49-56. PubMed ID: 15351279
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.