219 related articles for article (PubMed ID: 24036859)
1. A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.
Bahreyni Toossi MT; Behmadi M; Ghorbani M; Gholamhosseinian H
J Appl Clin Med Phys; 2013 Sep; 14(5):52-67. PubMed ID: 24036859
[TBL] [Abstract][Full Text] [Related]
2. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
Chibani O; Ma CM
Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
[TBL] [Abstract][Full Text] [Related]
3. Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.
Mesbahi A; Nejad FS
Radiat Med; 2007 Dec; 25(10):529-35. PubMed ID: 18085404
[TBL] [Abstract][Full Text] [Related]
4. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
Mesbahi A
Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
[TBL] [Abstract][Full Text] [Related]
5. Neutron dose equivalent and neutron spectra in tissue for clinical linacs operating at 15, 18 and 20 MV.
Martínez-Ovalle SA; Barquero R; Gómez-Ros JM; Lallena AM
Radiat Prot Dosimetry; 2011 Nov; 147(4):498-511. PubMed ID: 21233098
[TBL] [Abstract][Full Text] [Related]
6. A Monte Carlo study of neutron contamination in presence of circular cones during stereotactic radiotherapy with 18 MV photon beams.
Tajiki S; Nedaie HA; Rahmani F
Biomed Phys Eng Express; 2020 Apr; 6(3):035016. PubMed ID: 33438661
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.
Bahreyni Toossi MT; Ghorbani M; Akbari F; Mehrpouyan M; Sobhkhiz Sabet L
Australas Phys Eng Sci Med; 2016 Mar; 39(1):113-22. PubMed ID: 26581762
[TBL] [Abstract][Full Text] [Related]
8. Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation.
Yang J; Li JS; Qin L; Xiong W; Ma CM
Phys Med Biol; 2004 Jun; 49(12):2657-73. PubMed ID: 15272680
[TBL] [Abstract][Full Text] [Related]
9. Effect of Hip Prosthesis on Photon Beam Characteristics in Radiological Physics.
Bhushan M; Tripathi D; Yadav G; Kumar L; Dewan A; Kumar G
Asian Pac J Cancer Prev; 2020 Jun; 21(6):1731-1738. PubMed ID: 32592371
[TBL] [Abstract][Full Text] [Related]
10. Photoneutron production of a Siemens Primus linear accelerator studied by Monte Carlo methods and a paired magnesium and boron coated magnesium ionization chamber system.
Becker J; Brunckhorst E; Schmidt R
Phys Med Biol; 2007 Nov; 52(21):6375-87. PubMed ID: 17951849
[TBL] [Abstract][Full Text] [Related]
11. Investigation of the use of external aluminium targets for portal imaging in a medical accelerator using Geant4 Monte Carlo simulation.
Kim H; Kim B; Baek J; Oh Y; Yun S; Jang H
Br J Radiol; 2018 Apr; 91(1084):20170376. PubMed ID: 29338304
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study.
Prasada DNY; Ciamaudi N; Fadli M; Tursinah R; Pawiro SA
Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34619664
[TBL] [Abstract][Full Text] [Related]
13. Activation of hip prostheses in high energy radiotherapy and resultant dose to nearby tissue.
Keehan S; Smith RL; Millar J; Esser M; Taylor ML; Lonski P; Kron T; Franich RD
J Appl Clin Med Phys; 2017 Mar; 18(2):100-105. PubMed ID: 28300363
[TBL] [Abstract][Full Text] [Related]
14. PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators.
Brualla L; Rodriguez M; Sempau J; Andreo P
Radiat Oncol; 2019 Jan; 14(1):6. PubMed ID: 30634994
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the accuracy of various dose calculation algorithms of a commercial treatment planning system in the presence of hip prosthesis and comparison with Monte Carlo.
Mohammadi K; Hassani M; Ghorbani M; Farhood B; Knaup C
J Cancer Res Ther; 2017; 13(3):501-509. PubMed ID: 28862217
[TBL] [Abstract][Full Text] [Related]
16. PHITS simulations of absorbed dose out-of-field and neutron energy spectra for ELEKTA SL25 medical linear accelerator.
Puchalska M; Sihver L
Phys Med Biol; 2015 Jun; 60(12):N261-70. PubMed ID: 26057186
[TBL] [Abstract][Full Text] [Related]
17. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.
Cardenas CE; Nitsch PL; Kudchadker RJ; Howell RM; Kry SF
J Appl Clin Med Phys; 2016 Jul; 17(4):442-455. PubMed ID: 27455499
[TBL] [Abstract][Full Text] [Related]
18. Comparison of fast-neutron contamination of different models of Siemens medical linacs with CR-39 film.
Aftabi N; Yazdi MH; Ghorbani M; Abdollahi S
J Cancer Res Ther; 2021; 17(4):853-856. PubMed ID: 34528531
[TBL] [Abstract][Full Text] [Related]
19. Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18MV photon beam: Determination of initial electron beam parameters.
Najafzadeh M; Hoseini-Ghafarokhi M; Bolagh RSM; Haghparast M; Zarifi S; Nickfarjam A; Farhood B; Chow JCL
J Xray Sci Technol; 2019; 27(6):1047-1070. PubMed ID: 31498147
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams.
Dowlatabadi H; Mowlavi AA; Ghorbani M
J Biomed Phys Eng; 2017 Dec; 7(4):333-346. PubMed ID: 29616199
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]