134 related articles for article (PubMed ID: 24036864)
1. Total skin electron therapy in the lying-on-the-floor position using a customized flattening filter to eliminate field junctions.
Deufel CL; Antolak JA
J Appl Clin Med Phys; 2013 Sep; 14(5):115-26. PubMed ID: 24036864
[TBL] [Abstract][Full Text] [Related]
2. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
Almberg SS; Frengen J; Lindmo T
Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric characterization and optimization of a customized Stanford total skin electron irradiation (TSEI) technique.
Luĉić F; Sánchez-Nieto B; Caprile P; Zelada G; Goset K
J Appl Clin Med Phys; 2013 Sep; 14(5):231-42. PubMed ID: 24036877
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric comparison of 4 MeV and 6 MeV electron beams for total skin irradiation.
Park SY; Ahn BS; Park JM; Ye SJ; Kim IH; Kim JI
Radiat Oncol; 2014 Sep; 9():197. PubMed ID: 25194217
[TBL] [Abstract][Full Text] [Related]
5. A conceptual design of rotating board technique for delivering total skin electron therapy.
Wu JM; Yeh SA; Hsiao KY; Chao MM; Hargrove I
Med Phys; 2010 Apr; 37(4):1449-58. PubMed ID: 20443466
[TBL] [Abstract][Full Text] [Related]
6. Investigation of effect of filter on the stand-up technique for total skin irradiation by Monte Carlo simulation.
Tseng W; Li R; Wu Q
J Appl Clin Med Phys; 2021 Jan; 22(1):137-145. PubMed ID: 33314659
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric parameters calculation for 18 MV photon beam in flattening filter (FF) and flattening filter free (FFF) linear accelerators with and without magnetic deflector and lead filter.
Hashemizadeh M; Zabihzadeh M; Shahbazian H; Fatahi-Asl J; Reshadatian M
Biomed Phys Eng Express; 2024 Feb; 10(2):. PubMed ID: 38316026
[TBL] [Abstract][Full Text] [Related]
8. Validation of the dosimetry of total skin irradiation techniques by Monte Carlo simulation.
Li R; Tseng W; Wu Q
J Appl Clin Med Phys; 2020 Aug; 21(8):107-119. PubMed ID: 32559022
[TBL] [Abstract][Full Text] [Related]
9. Verification of Surface Dose for Flattening Filter and Flattening Filter Free Beams in Beam-Matched Medical Linear Accelerators.
Sushma N; Kaginelli S; Palanivel S; Ganesh KM
Asian Pac J Cancer Prev; 2021 Aug; 22(8):2577-2585. PubMed ID: 34452573
[TBL] [Abstract][Full Text] [Related]
10. Lying-on position of total skin electron therapy.
Wu JM; Leung SW; Wang CJ; Chui CS
Int J Radiat Oncol Biol Phys; 1997 Sep; 39(2):521-8. PubMed ID: 9308958
[TBL] [Abstract][Full Text] [Related]
11. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields.
Pavón EC; Sánchez-Doblado F; Leal A; Capote R; Lagares JI; Perucha M; Arráns R
Phys Med Biol; 2003 Sep; 48(17):2783-96. PubMed ID: 14516101
[TBL] [Abstract][Full Text] [Related]
12. Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.
Chen Z; Agostinelli AG; Wilson LD; Nath R
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):872-85. PubMed ID: 15183491
[TBL] [Abstract][Full Text] [Related]
13. Validation of a Monte Carlo model for multi leaf collimator based electron delivery.
Kaluarachchi MM; Saleh ZH; Schwer ML; Klein EE
Med Phys; 2020 Aug; 47(8):3586-3599. PubMed ID: 32324289
[TBL] [Abstract][Full Text] [Related]
14. Comparison of measured electron energy spectra for six matched, radiotherapy accelerators.
McLaughlin DJ; Hogstrom KR; Neck DW; Gibbons JP
J Appl Clin Med Phys; 2018 May; 19(3):183-192. PubMed ID: 29603874
[TBL] [Abstract][Full Text] [Related]
15. A technique for total skin electron therapy (TSET) of an anesthetized pediatric patient.
Kron T; Donahoo G; Lonski P; Wheeler G
J Appl Clin Med Phys; 2018 Nov; 19(6):109-116. PubMed ID: 30267453
[TBL] [Abstract][Full Text] [Related]
16. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
Dalaryd M; Knöös T; Ceberg C
Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric evaluation of electron total skin irradiation using gafchromic film and thermoluminescent dosimetry.
Falahati L; Nedaie HA; Esfahani M; Banaee N
J Cancer Res Ther; 2019 Mar; 15(Supplement):S115-S122. PubMed ID: 30900632
[TBL] [Abstract][Full Text] [Related]
18. Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator.
Jin L; Eldib A; Li J; Emam I; Fan J; Wang L; Ma CM
J Appl Clin Med Phys; 2014 Jan; 15(1):4506. PubMed ID: 24423848
[TBL] [Abstract][Full Text] [Related]
19. The Measurement of the Surface Dose in Regular and Small Radiation Therapy Fields Using Cherenkov Imaging.
Li Y; Liu H; Huang N; Wang Z; Zhang C
Technol Cancer Res Treat; 2022; 21():15330338211073432. PubMed ID: 35119327
[No Abstract] [Full Text] [Related]
20. Monte carlo electron source model validation for an Elekta Precise linac.
Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]