These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 24042104)

  • 21. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries.
    Boehme CC; Nabeta P; Henostroza G; Raqib R; Rahim Z; Gerhardt M; Sanga E; Hoelscher M; Notomi T; Hase T; Perkins MD
    J Clin Microbiol; 2007 Jun; 45(6):1936-40. PubMed ID: 17392443
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Decentralization of CD4 testing in resource-limited settings: 7 years of experience in six African countries.
    Marinucci F; Medina-Moreno S; Paterniti AD; Wattleworth M; Redfield RR
    Cytometry A; 2011 May; 79(5):368-74. PubMed ID: 21495181
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [How to cope with the global tuberculosis burden--experiences and perspectives for Japan's international cooperation].
    Ishikawa N
    Kekkaku; 2005 Feb; 80(2):89-94. PubMed ID: 15920981
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Critical appraisal of current recommendations and practices for tuberculosis sputum smear microscopy.
    Gilpin C; Kim SJ; Lumb R; Rieder HL; Van Deun A;
    Int J Tuberc Lung Dis; 2007 Sep; 11(9):946-52. PubMed ID: 17705970
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Laboratory quality improvement in Tanzania.
    Andiric LR; Massambu CG
    Am J Clin Pathol; 2015 Apr; 143(4):566-72. PubMed ID: 25780009
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Tuberculosis bacteriology laboratory services and incremental protocols for developing countries.
    Laszlo A
    Clin Lab Med; 1996 Sep; 16(3):697-716. PubMed ID: 8866187
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Light-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.
    Habtamu M; van den Boogaard J; Ndaro A; Buretta R; Irongo CF; Lega DA; Nyombi BM; Kibiki GS
    Int J Tuberc Lung Dis; 2012; 16(3):402-7. PubMed ID: 22640455
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Recommended standards for modern tuberculosis laboratory services in Europe.
    Drobniewski FA; Hoffner S; Rusch-Gerdes S; Skenders G; Thomsen V;
    Eur Respir J; 2006 Nov; 28(5):903-9. PubMed ID: 16899481
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Utilization management: a European perspective.
    Plebani M; Zaninotto M; Faggian D
    Clin Chim Acta; 2014 Jan; 427():137-41. PubMed ID: 23499570
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Critical role of developing national strategic plans as a guide to strengthen laboratory health systems in resource-poor settings.
    Nkengasong JN; Mesele T; Orloff S; Kebede Y; Fonjungo PN; Timperi R; Birx D
    Am J Clin Pathol; 2009 Jun; 131(6):852-7. PubMed ID: 19461093
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tuberculosis: a snap shot picture.
    Anil P
    Health Millions; 1995; 21(1):8-9. PubMed ID: 12288997
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Improvement of routine works and quality control in mycobacterial laboratory].
    Suzuki K; Higuchi T
    Kekkaku; 2007 Mar; 82(3):217-27. PubMed ID: 17444126
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Reconsideration of the admission and discharge criteria of tuberculosis patients in Japan].
    Masuyama H; Igari H
    Kekkaku; 2013 Mar; 88(3):373-85. PubMed ID: 23672177
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Safety in laboratories carrying out sputum smear microscopy: a dilemma for resource-poor countries.
    Nyirenda TE; Mundy CJ; Harries AD; Banerjee A; Salaniponi FM
    Int J Tuberc Lung Dis; 1998 Aug; 2(8):690-3. PubMed ID: 9712286
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Implementation of proficiency testing in conjunction with a rechecking system for external quality assurance in tuberculosis laboratories in Mexico.
    Martinez-Guarneros A; Balandrano-Campos S; Solano-Ceh MA; Gonzalez-Dominguez F; Lipman HB; Ridderhof JC; Flisser A
    Int J Tuberc Lung Dis; 2003 Jun; 7(6):516-21. PubMed ID: 12797692
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Laboratory equipment maintenance: a critical bottleneck for strengthening health systems in sub-Saharan Africa?
    Fonjungo PN; Kebede Y; Messele T; Ayana G; Tibesso G; Abebe A; Nkengasong JN; Kenyon T
    J Public Health Policy; 2012 Feb; 33(1):34-45. PubMed ID: 22071568
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Impact of the RNTCPIRL-EQA-OSE visits on quality of sputum smear microscopy services of Gujarat, India.
    Patel ND; Rade K; Dave PV; Pujara K; Solanki RN; Vegad MM; Modi B; Shah A
    Indian J Tuberc; 2012 Jan; 59(1):12-7. PubMed ID: 22670506
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Utilization management in toxicology.
    Zhang Y; Kwong TC
    Clin Chim Acta; 2014 Jan; 427():158-66. PubMed ID: 24091099
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Quality assessment of microscopic examination in tuberculosis diagnostic laboratories: a preliminary study].
    Simşek H; Ceyhan I; Tarhan G; Güner U
    Mikrobiyol Bul; 2010 Oct; 44(4):561-9. PubMed ID: 21063968
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The National Tuberculosis Programme and its implementation.
    Banerji D
    Health Millions; 1995; 21(1):2-3. PubMed ID: 12288991
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.