415 related articles for article (PubMed ID: 24045545)
21. Comparison of platelet counts by CellDyn Sapphire (Abbot Diagnostics), LH750 (Beckman Coulter), ReaPanThrombo immunoplatelet method (ReaMetrix), and the international flow reference method, in thrombocytopenic blood samples.
Sehgal K; Badrinath Y; Tembhare P; Subramanian PG; Talole S; Kumar A; Gadage V; Mahadik S; Ghogale S; Gujral S
Cytometry B Clin Cytom; 2010 Jul; 78(4):279-85. PubMed ID: 20229505
[TBL] [Abstract][Full Text] [Related]
22. Micro-Red Blood Cell, Fragmented Red Blood Cell, Platelet Distribution Width, Mean Platelet Volume, and Platelet-Large Cell Ratio on Sysmex XN Series Hematology Analyzers Can Be Used for the Reflex Test of Impedance Platelet Count in Clinical Practice.
Chen S; Mao Z; Wang S; Deng J; Liao H; Zheng Q
Arch Pathol Lab Med; 2024 Jan; 148(1):61-67. PubMed ID: 37014982
[TBL] [Abstract][Full Text] [Related]
23. Analytical performance of automated platelet counts and impact on platelet transfusion guidance in patients with acute leukemia.
Tantanate C; Khowawisetsut L; Sukapirom K; Pattanapanyasat K
Scand J Clin Lab Invest; 2019 May; 79(3):160-166. PubMed ID: 30761915
[TBL] [Abstract][Full Text] [Related]
24. Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.
Segal HC; Briggs C; Kunka S; Casbard A; Harrison P; Machin SJ; Murphy MF
Br J Haematol; 2005 Feb; 128(4):520-5. PubMed ID: 15686462
[TBL] [Abstract][Full Text] [Related]
25. Counting platelets in platelet concentrates on hematology analyzers: a multicenter comparative study.
van der Meer PF; Dijkstra-Tiekstra MJ; Mahon A; de Wildt-Eggen J;
Transfusion; 2009 Jan; 49(1):81-90. PubMed ID: 18954409
[TBL] [Abstract][Full Text] [Related]
26. Selection of Automated Platelet Counting Methods Based on Mean Platelet Volume (MPV).
Wang Z; Jin X; Wang S; You Q; Wang J; Xu D
Clin Lab; 2023 May; 69(5):. PubMed ID: 37145064
[TBL] [Abstract][Full Text] [Related]
27. A flow cytometric method for platelet counting in platelet concentrates.
van der Meer PF; Karssing-van Leeuwen W; Kurtz J; Spengler HP; Blair A; Devine D; Harrison P; Lambrecht B; VandenBroeke T; de Wildt J; de Korte D;
Transfusion; 2012 Jan; 52(1):173-80. PubMed ID: 21790632
[TBL] [Abstract][Full Text] [Related]
28. Enumeration of platelets by multiparameter flow cytometry using platelet-specific antibodies and fluorescent reference particles.
Dickerhoff R; Von Ruecker A
Clin Lab Haematol; 1995 Jun; 17(2):163-72. PubMed ID: 8536420
[TBL] [Abstract][Full Text] [Related]
29. Application of the Fluorescence Method on Sysmex XN9000 Hematology Analyzer for Correcting Platelet Count in Individuals with Microcytosis.
Deng J; Xie S; Chen Y; Ma Q; He Y; Liu M; Wang D; Yu X
Lab Med; 2023 Jan; 54(1):e10-e13. PubMed ID: 35713611
[TBL] [Abstract][Full Text] [Related]
30. Performance evaluation of a novel platelet count parameter, hybrid platelet count, on the BC-780 automated hematology analyzer.
Prompetchara E; Parnsamut C; Chirapanuruk A; Ketloy C
Clin Chem Lab Med; 2024 Mar; 62(4):690-697. PubMed ID: 37855253
[TBL] [Abstract][Full Text] [Related]
31. Performance evaluation of the new hematology analyzer Sysmex XN-series.
Seo JY; Lee ST; Kim SH
Int J Lab Hematol; 2015 Apr; 37(2):155-64. PubMed ID: 24815300
[TBL] [Abstract][Full Text] [Related]
32. Performance of automated platelet quantification using different analysers in comparison with an immunological reference method in thrombocytopenic patients.
Trabuio E; Valverde S; Antico F; Manoni F; Gessoni G
Blood Transfus; 2009 Jan; 7(1):43-8. PubMed ID: 19290080
[TBL] [Abstract][Full Text] [Related]
33. Problems with platelet counting in thrombocytopenia. A rapid manual method to measure low platelet counts.
Sutor AH; Grohmann A; Kaufmehl K; Wündisch T
Semin Thromb Hemost; 2001 Jun; 27(3):237-43. PubMed ID: 11446657
[TBL] [Abstract][Full Text] [Related]
34. External quality assessment of automated hematology analyzer performance using fresh human blood samples in Shanghai.
Xiaobo H; Yong L; Daming J; Lei X; Ying S; Jinfeng Z
Lab Hematol; 2003; 9(3):175-8. PubMed ID: 14521326
[TBL] [Abstract][Full Text] [Related]
35. A rapid and accurate closed-tube immunoassay for platelets on an automated hematology analyzer.
Gill JE; Davis KA; Cowart WJ; Nepacena FU; Kim YR
Am J Clin Pathol; 2000 Jul; 114(1):47-56. PubMed ID: 10884799
[TBL] [Abstract][Full Text] [Related]
36. Measurement uncertainty of platelet concentration using the Sysmex XN automated hematology analyzer.
Lim YK; Kweon OJ; Choi JH; Lee W; Park AJ
Scand J Clin Lab Invest; 2018 May; 78(3):224-229. PubMed ID: 29455564
[TBL] [Abstract][Full Text] [Related]
37. Performance of the Sysmex XN-V hematology analyzer in determining the immature platelet fraction in dogs: A preliminary study and reference values.
Jornet-Rius O; Mesalles-Naranjo M; Pastor J
Vet Clin Pathol; 2023 Sep; 52(3):433-442. PubMed ID: 37468992
[TBL] [Abstract][Full Text] [Related]
38. Performance of automated digital cell imaging analyzer Sysmex DI-60.
Kim HN; Hur M; Kim H; Kim SW; Moon HW; Yun YM
Clin Chem Lab Med; 2017 Nov; 56(1):94-102. PubMed ID: 28672770
[TBL] [Abstract][Full Text] [Related]
39. Performance evaluation of the Sysmex pocH-100i automated hematology analyzer.
Whisler S; Dahlgren C
Lab Hematol; 2005; 11(2):107-17. PubMed ID: 16024334
[TBL] [Abstract][Full Text] [Related]
40. Enhanced accuracy of optical platelet counts in microcytic anemia.
Pan LL; Chen CM; Huang WT; Sun CK
Lab Med; 2014; 45(1):32-6. PubMed ID: 24719982
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]