These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 24047234)

  • 1. Solid contact ion-selective electrodes with a well-controlled Co(II)/Co(III) redox buffer layer.
    Zou XU; Cheong JH; Taitt BJ; Bühlmann P
    Anal Chem; 2013 Oct; 85(19):9350-5. PubMed ID: 24047234
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact.
    Zou XU; Zhen XV; Cheong JH; Bühlmann P
    Anal Chem; 2014 Sep; 86(17):8687-92. PubMed ID: 25117517
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ferrocene bound poly(vinyl chloride) as ion to electron transducer in electrochemical ion sensors.
    Pawlak M; Grygolowicz-Pawlak E; Bakker E
    Anal Chem; 2010 Aug; 82(16):6887-94. PubMed ID: 20666464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ion-selective electrodes with colloid-imprinted mesoporous carbon as solid contact.
    Hu J; Zou XU; Stein A; Bühlmann P
    Anal Chem; 2014 Jul; 86(14):7111-8. PubMed ID: 24983327
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Functionalizing Carbon Substrates with a Covalently Attached Cobalt Redox Buffer for Calibration-Free Solid-Contact Ion-Selective Electrodes.
    Kim M; Dong XIN; Spindler BD; Bühlmann P; Stein A
    Anal Chem; 2024 May; 96(19):7558-7565. PubMed ID: 38696396
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Micromethod for the investigation of the interactions between DNA and redox-active molecules.
    Pang DW; Abruña HD
    Anal Chem; 1998 Aug; 70(15):3162-9. PubMed ID: 11013719
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Covalent binding of sensor phases--a recipe for stable potentials of solid-state ion-selective sensors.
    Grygołowicz-Pawlak E; Palys B; Biesiada K; Olszyna AR; Malinowska E
    Anal Chim Acta; 2008 Sep; 625(2):137-44. PubMed ID: 18724987
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hydrogels Doped with Redox Buffers as Transducers for Ion-Selective Electrodes.
    Rousseau CR; Honig ML; Bühlmann P
    Anal Chem; 2022 Jan; 94(2):1143-1150. PubMed ID: 34932309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Redox Buffer Capacity of Ion-Selective Electrode Solid Contacts Doped with Organometallic Complexes.
    Zhen XV; Rousseau CR; Bühlmann P
    Anal Chem; 2018 Sep; 90(18):11000-11007. PubMed ID: 30141325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Self-assembly and heterogeneous electron transfer properties of metallo-octacarboxyphthalocyanine complexes on gold electrode.
    Agboola BO; Ozoemena KI
    Phys Chem Chem Phys; 2008 May; 10(17):2399-408. PubMed ID: 18414731
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clarification of the oxidation state of cobalt corroles in heterogeneous and homogeneous catalytic reduction of dioxygen.
    Kadish KM; Shen J; Frémond L; Chen P; El Ojaimi M; Chkounda M; Gros CP; Barbe JM; Ohkubo K; Fukuzumi S; Guilard R
    Inorg Chem; 2008 Aug; 47(15):6726-37. PubMed ID: 18582035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A solid-contact Ca
    Zeng X; Qin W
    Talanta; 2020 Mar; 209():120570. PubMed ID: 31892074
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrochemical redox control of ferrocene using a supramolecular assembly of ferrocene-linked C(60) derivative and metallooctaethylporphyrin array on a Au(111) electrode.
    Yoshimoto S; Saito A; Tsutsumi E; D'Souza F; Ito O; Itaya K
    Langmuir; 2004 Dec; 20(25):11046-52. PubMed ID: 15568857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Layer-by-layer self assembly of a water-soluble phthalocyanine on gold. Application to the electrochemical determination of hydrogen peroxide.
    Koodlur LS
    Bioelectrochemistry; 2013 Jun; 91():21-7. PubMed ID: 23333646
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of water uptake of polymeric ion-selective membranes with the coulometric Karl Fischer and FT-IR-attenuated total reflection techniques.
    He N; Lindfors T
    Anal Chem; 2013 Jan; 85(2):1006-12. PubMed ID: 23249325
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adsorption of 1,10-phenanthroline within a dodecanethiol monolayer: an approach to a switchable electrode surface.
    Hou KY; Yu L; Severson MW; Zeng X
    J Phys Chem B; 2005 May; 109(19):9527-31. PubMed ID: 16852146
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative electrooxidation of sulphite by self-assembled monolayers (SAMs) of Co(II), Fe(II), Ni(II) and Mn(III) tetrakis benzylmercapto and dodecylmercapto metallophthalocyanines complexes on gold electrodes.
    Agboola B; Nyokong T
    Talanta; 2007 Apr; 72(2):691-8. PubMed ID: 19071674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extended-gate FET-based enzyme sensor with ferrocenyl-alkanethiol modified gold sensing electrode.
    Ishige Y; Shimoda M; Kamahori M
    Biosens Bioelectron; 2009 Jan; 24(5):1096-102. PubMed ID: 18672358
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sophisticated design of PVC membrane ion-selective electrodes based on the mixed potential theory.
    Imoto M; Sakaki T; Osakai T
    Anal Chem; 2013 May; 85(9):4753-60. PubMed ID: 23594104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ion-selective electrodes using multi-walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate.
    Parra EJ; Crespo GA; Riu J; Ruiz A; Rius FX
    Analyst; 2009 Sep; 134(9):1905-10. PubMed ID: 19684918
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.