These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 24050786)

  • 21. Retained embolized fragment of totally implantable central venous catheter in right ventricle: it is really necessary to remove?
    Tazzioli G; Gargaglia E; Vecchioni I; Papi S; Di Blasio P; Rossi R
    J Vasc Access; 2015; 16(5):431-3. PubMed ID: 26109543
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Pinch-off syndrome and rupture of totally implanted venous access. Report of a case].
    Ferrari A; Nahas S; Maccaferri R; Malacarne P
    Recenti Prog Med; 2000 Jun; 91(6):297-300. PubMed ID: 11512387
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Catheter fracture and embolization associated with arm implantation of the cook vital port.
    Burbridge B; Stoneham G; Szkup P; Otani R; Kriegler S
    Can Assoc Radiol J; 2013 Aug; 64(3):269-73. PubMed ID: 22867962
    [TBL] [Abstract][Full Text] [Related]  

  • 24. "Spontaneous" catheter fracture and embolization of a totally implanted venous access port.
    van der Hem KG; Meijer S; Werter CJ; van Groeningen CJ
    Neth J Med; 1991 Jun; 38(5-6):262-4. PubMed ID: 1922600
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detachment and embolization of totally implantable central venous access devices: diagnosis and management.
    Kara H; Arikan AE; Dulgeroglu O; Uras C; Icten GE; Tutar B; Parlakkilic UT; Sonmez O
    Acta Chir Belg; 2022 Aug; 122(4):240-247. PubMed ID: 33645456
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Case report: the malfunctioning implanted venous access device.
    Schummer W; Schummer C; Schelenz C
    Br J Nurs; 2003 Feb 27-Mar 12; 12(4):210, 212-4. PubMed ID: 12671566
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Percutaneous removal of an in-situ embolised catheter fragment in a patient with Port-A-Cath].
    Raungaard B; Thuesen L
    Ugeskr Laeger; 1995 Dec; 157(51):7152-3. PubMed ID: 8545932
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Incidence of mechanical malfunction in low-profile subcutaneous implantable venous access devices in patients receiving chemotherapy for gynecologic malignancies.
    Subramaniam A; Kim KH; Bryant SA; Kimball KJ; Huh WK; Straughn JM; Estes JM; Alvarez RD
    Gynecol Oncol; 2011 Oct; 123(1):54-7. PubMed ID: 21742372
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Late fracture of Groshong ports: A report of the three cases.
    Saijo F; Mutoh M; Tokumine J; Yoshinobu O; Hama H; Namima T; Shibahara M; Tokumura H
    J Vasc Access; 2019 Sep; 20(5):563-566. PubMed ID: 30854915
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transluminal removal of a fractured and embolized indwelling central venous catheter in the pulmonary artery.
    Kim OK; Kim SH; Kim JB; Jeon WS; Jo SH; Lee JH; Ko JH
    Korean J Intern Med; 2006 Sep; 21(3):187-90. PubMed ID: 17017669
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pulmonary embolism secondary to fragmentation of a Port-a-Cath catheter.
    Sbrana F; Coceani M; Schlueter M; Rovai D; Ciardetti M
    Minerva Anestesiol; 2014 Oct; 80(10):1143-4. PubMed ID: 24518217
    [No Abstract]   [Full Text] [Related]  

  • 32. [Fracture and embolization of implantable subclavian venous catheter fragments due to costoclavicular compression: pinch-off syndrome].
    Pérez Bergara E; Pavón Benito A; Lánderer Vázquez T; Salvador Bravo M; Aizcorbe Garralda M; Zugasti O
    Rev Esp Anestesiol Reanim; 2009 Feb; 56(2):115-8. PubMed ID: 19334661
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Catheter fracture: a rare complication of totally implantable venous devices.
    Maisey NR; Sacks N; Johnston SR
    Breast; 2003 Aug; 12(4):287-9. PubMed ID: 14659316
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Complete catheter disconnection and migration of an implantable venous access device: the disconnected cap sign.
    Faraj W; Zaghal A; El-Beyrouthy O; Kutoubi A
    Ann Vasc Surg; 2010 Jul; 24(5):692.e11-5. PubMed ID: 20413259
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Distal fragmented port catheter: case report and review of literature.
    Colón-Casasnovas NE; Lugo-Vicente H
    Bol Asoc Med P R; 2008; 100(1):70-5. PubMed ID: 18763398
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Percutaneous transcatheter retrieval of intracardiac central venous catheter fragments in two infants using Amplatz Goose Neck snare.
    Tutar E; Aypar E; Atalay S; Yavuz G; Doğu F
    Turk J Pediatr; 2009; 51(5):519-23. PubMed ID: 20112614
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Catheter fracture and cardiac migration of a totally implantable venous device.
    Kapadia S; Parakh R; Grover T; Yadav A
    Indian J Cancer; 2005; 42(3):155-7. PubMed ID: 16276017
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fracture and migration of implantable venous access port catheters: Cause analysis and management of 4 cases.
    Xiao SP; Xiong B; Chu J; Li XF; Yao Q; Zheng CS
    J Huazhong Univ Sci Technolog Med Sci; 2015 Oct; 35(5):763-765. PubMed ID: 26489636
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Spontaneous rupture and embolization: a rare complication of port catheter implantation].
    Seelig SK; Klingler PJ; Waldenberger P
    Dtsch Med Wochenschr; 2000 May; 125(20):628-30. PubMed ID: 11256046
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Fracture and embolization of a central venous port catheter without prior compression between the clavicle and the 1st rib].
    Lenglinger FX; Hartl P; Kirchgatterer A; Lenglinger GM; Baldinger C
    Wien Klin Wochenschr; 2001 Feb; 113(3-4):134-7. PubMed ID: 11253740
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.