These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1147 related articles for article (PubMed ID: 24050862)
21. Usefulness of contrast injection during balloon aortic valvuloplasty before transcatheter aortic valve replacement: a pilot study. Barbanti M; Sgroi C; Immè S; Aruta P; Deste W; Gulino S; Cannata S; Giarratana A; Bottari V; Giannazzo D; Garretto V; Patanè M; Benvenuto E; Capodanno D; Tamburino C EuroIntervention; 2014 Jun; 10(2):241-7. PubMed ID: 24334876 [TBL] [Abstract][Full Text] [Related]
22. Transfemoral implantation of Edwards Sapien XT aortic valve without previous valvuloplasty: role of 2D/3D transesophageal echocardiography. García E; Almería C; Unzué L; Jiménez-Quevedo P; Cuadrado A; Macaya C Catheter Cardiovasc Interv; 2014 Nov; 84(6):868-76. PubMed ID: 24482054 [TBL] [Abstract][Full Text] [Related]
23. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis. Schultz CJ; Tzikas A; Moelker A; Rossi A; Nuis RJ; Geleijnse MM; van Mieghem N; Krestin GP; de Feyter P; Serruys PW; de Jaegere PP Catheter Cardiovasc Interv; 2011 Sep; 78(3):446-55. PubMed ID: 21793166 [TBL] [Abstract][Full Text] [Related]
24. Heart-rate adjustment of transcatheter haemodynamics improves the prognostic evaluation of paravalvular regurgitation after transcatheter aortic valve implantation. Jilaihawi H; Chakravarty T; Shiota T; Rafique A; Harada K; Shibayama K; Doctor N; Kashif M; Nakamura M; Mirocha J; Rami T; Okuyama K; Cheng W; Sadruddin O; Siegel R; Makkar RR EuroIntervention; 2015 Aug; 11(4):456-64. PubMed ID: 25499834 [TBL] [Abstract][Full Text] [Related]
25. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis. Kamperidis V; van Rosendael PJ; de Weger A; Katsanos S; Regeer M; van der Kley F; Mertens B; Sianos G; Ajmone Marsan N; Bax JJ; Delgado V JACC Cardiovasc Interv; 2015 Apr; 8(5):670-7. PubMed ID: 25946438 [TBL] [Abstract][Full Text] [Related]
26. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Sieswerda G; Budde R; van der Linden M; Juthier F; Banfi C; Hurt C; Samim M; Hillaert M; van Herwerden L; Bertrand ME; Doevendans PA; Van Belle E J Thorac Cardiovasc Surg; 2013 Feb; 145(2):398-405. PubMed ID: 22377664 [TBL] [Abstract][Full Text] [Related]
27. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study. Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501 [TBL] [Abstract][Full Text] [Related]
28. Pre-Procedural Hemodynamic Status Improves the Discriminatory Value of the Aortic Regurgitation Index in Patients Undergoing Transcatheter Aortic Valve Replacement. Sinning JM; Stundl A; Pingel S; Weber M; Sedaghat A; Hammerstingl C; Vasa-Nicotera M; Mellert F; Schiller W; Kovac J; Welz A; Grube E; Werner N; Nickenig G JACC Cardiovasc Interv; 2016 Apr; 9(7):700-11. PubMed ID: 27056309 [TBL] [Abstract][Full Text] [Related]
29. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034 [TBL] [Abstract][Full Text] [Related]
30. The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. Binder RK; Webb JG; Willson AB; Urena M; Hansson NC; Norgaard BL; Pibarot P; Barbanti M; Larose E; Freeman M; Dumont E; Thompson C; Wheeler M; Moss RR; Yang TH; Pasian S; Hague CJ; Nguyen G; Raju R; Toggweiler S; Min JK; Wood DA; Rodés-Cabau J; Leipsic J J Am Coll Cardiol; 2013 Jul; 62(5):431-8. PubMed ID: 23684679 [TBL] [Abstract][Full Text] [Related]
31. Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: the role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth. Ali OF; Schultz C; Jabbour A; Rubens M; Mittal T; Mohiaddin R; Davies S; Di Mario C; Van der Boon R; Ahmad AS; Amrani M; Moat N; De Jaegere PP; Dalby M Int J Cardiol; 2015 Jan; 179():539-45. PubMed ID: 25466563 [TBL] [Abstract][Full Text] [Related]
32. Clinical profile and outcome of patients with severe aortic stenosis at high surgical risk: single-center prospective evaluation according to treatment assignment. Dvir D; Sagie A; Porat E; Assali A; Shapira Y; Vaknin-Assa H; Shafir G; Bental T; Nevzorov R; Battler A; Kornowski R Catheter Cardiovasc Interv; 2013 Apr; 81(5):871-81. PubMed ID: 22915555 [TBL] [Abstract][Full Text] [Related]
33. Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system. Binder RK; Schäfer U; Kuck KH; Wood DA; Moss R; Leipsic J; Toggweiler S; Freeman M; Ostry AJ; Frerker C; Willson AB; Webb JG JACC Cardiovasc Interv; 2013 Mar; 6(3):301-7. PubMed ID: 23517843 [TBL] [Abstract][Full Text] [Related]
34. Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: predictive value for aortic regurgitation after transcatheter aortic valve replacement. Masri A; Schoenhagen P; Svensson L; Kapadia SR; Griffin BP; Tuzcu EM; Desai MY J Thorac Cardiovasc Surg; 2014 Jun; 147(6):1847-54. PubMed ID: 23870156 [TBL] [Abstract][Full Text] [Related]
35. Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve. Binder RK; Rodés-Cabau J; Wood DA; Mok M; Leipsic J; De Larochellière R; Toggweiler S; Dumont E; Freeman M; Willson AB; Webb JG JACC Cardiovasc Interv; 2013 Mar; 6(3):293-300. PubMed ID: 23517842 [TBL] [Abstract][Full Text] [Related]
36. Initial findings using the V8 hourglass-shaped valvuloplasty balloon for postdilatation in treating paravalvular leaks associated with transcatheter self-expanding aortic valve prosthesis. Latib A; Pedersen W; Maisano F; Lesser J; Ruparelia N; Figini F; Colombo A; Poulose A; Kolbeck J; Mooney M; Schwartz R; Youssef A; Ungs D; Goldenberg I; Sorajja P Catheter Cardiovasc Interv; 2016 Jun; 87(7):1306-13. PubMed ID: 26945697 [TBL] [Abstract][Full Text] [Related]
37. Increased Risk of Cerebral Embolization After Implantation of a Balloon-Expandable Aortic Valve Without Prior Balloon Valvuloplasty. Bijuklic K; Haselbach T; Witt J; Krause K; Hansen L; Gehrckens R; Rieß FC; Schofer J JACC Cardiovasc Interv; 2015 Oct; 8(12):1608-13. PubMed ID: 26386760 [TBL] [Abstract][Full Text] [Related]
38. Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions. Schaefer A; Linder M; Treede H; Deuschl F; Schofer N; Seiffert M; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L Clin Res Cardiol; 2016 Jul; 105(7):585-91. PubMed ID: 26680213 [TBL] [Abstract][Full Text] [Related]
39. Transfemoral TAVI without pre-dilatation using balloon-expandable devices: a case-matched analysis. Conradi L; Schaefer A; Seiffert M; Schirmer J; Schaefer U; Schön G; Blankenberg S; Reichenspurner H; Treede H; Diemert P Clin Res Cardiol; 2015 Sep; 104(9):735-42. PubMed ID: 25725778 [TBL] [Abstract][Full Text] [Related]