These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 24054678)

  • 1. Evaluation of adsorbents for volatile methyl siloxanes sampling based on the determination of their breakthrough volume.
    Lamaa L; Ferronato C; Fine L; Jaber F; Chovelon JM
    Talanta; 2013 Oct; 115():881-6. PubMed ID: 24054678
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs).
    Gallego E; Roca FJ; Perales JF; Guardino X
    Talanta; 2010 May; 81(3):916-24. PubMed ID: 20298873
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of breakthrough volumes of volatile chemical warfare agents on a poly(2,6-diphenylphenylene oxide)-based adsorbent and application to thermal desorption-gas chromatography/mass spectrometric analysis.
    Kanamori-Kataoka M; Seto Y
    J Chromatogr A; 2015 Sep; 1410():19-27. PubMed ID: 26239699
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of adsorbents for sample preconcentration in compound-specific isotope analysis of common vapor intrusion pollutants.
    Klisch M; Kuder T; Philp RP; McHugh TE
    J Chromatogr A; 2012 Dec; 1270():20-7. PubMed ID: 23177155
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multisorbent tubes for collecting volatile organic compounds in spacecraft air.
    Matney ML; Beck SW; Limero TF; James JT
    AIHAJ; 2000; 61(1):69-75. PubMed ID: 10772617
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of sorbent materials for the sampling and analysis of phosphine, sulfuryl fluoride and methyl bromide in air.
    Magnusson R; Rittfeldt L; Åstot C
    J Chromatogr A; 2015 Jan; 1375():17-26. PubMed ID: 25512126
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safe Sampling Volume determinations of 12 volatile organic compounds on Carboxen 1003, Carbopack-X & Tenax-TA.
    Butterfield DM; Lipscombe RP; Gardiner TD
    J Chromatogr A; 2020 Aug; 1626():461369. PubMed ID: 32797848
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Behaviour and adsorptive removal of siloxanes in sewage sludge biogas.
    Oshita K; Ishihara Y; Takaoka M; Takeda N; Matsumoto T; Morisawa S; Kitayama A
    Water Sci Technol; 2010; 61(8):2003-12. PubMed ID: 20388997
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Siloxanes in Biogas: Approaches of Sampling Procedure and GC-MS Method Determination.
    Piechota G
    Molecules; 2021 Mar; 26(7):. PubMed ID: 33808478
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative study of the adsorption performance of an active multi-sorbent bed tube (Carbotrap, Carbopack X, Carboxen 569) and a Radiello(®) diffusive sampler for the analysis of VOCs.
    Gallego E; Roca FJ; Perales JF; Guardino X
    Talanta; 2011 Jul; 85(1):662-72. PubMed ID: 21645756
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of linear and cyclic volatile methyl siloxanes in biogas and biomethane by solid-phase microextraction and gas chromatography-mass spectrometry.
    Ghidotti M; Fabbri D; Torri C
    Talanta; 2019 Apr; 195():258-264. PubMed ID: 30625541
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Siloxanes removal from biogas by high surface area adsorbents.
    Gislon P; Galli S; Monteleone G
    Waste Manag; 2013 Dec; 33(12):2687-93. PubMed ID: 24075968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration and application of a passive air sampler (XAD-PAS) for volatile methyl siloxanes.
    Krogseth IS; Zhang X; Lei YD; Wania F; Breivik K
    Environ Sci Technol; 2013 May; 47(9):4463-70. PubMed ID: 23527480
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Screening method for pesticides in air by gas chromatography/tandem mass spectrometry.
    Egea Gonzalez FJ; Mena Granero A; Glass CR; Garrido Frenich A; Martinez Vidal JL
    Rapid Commun Mass Spectrom; 2004; 18(5):537-43. PubMed ID: 14978798
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel approach to evaluation of adsorbents for sampling indoor volatile organic compounds associated with symptom reports.
    Glas B; Stenberg B; Stenlund H; Sunesson AL
    J Environ Monit; 2008 Nov; 10(11):1297-303. PubMed ID: 18974898
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Differences in volatile methyl siloxane (VMS) profiles in biogas from landfills and anaerobic digesters and energetics of VMS transformations.
    Tansel B; Surita SC
    Waste Manag; 2014 Nov; 34(11):2271-7. PubMed ID: 25160660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MOF-5 metal-organic framework as sorbent for in-field sampling and preconcentration in combination with thermal desorption GC/MS for determination of atmospheric formaldehyde.
    Gu ZY; Wang G; Yan XP
    Anal Chem; 2010 Feb; 82(4):1365-70. PubMed ID: 20095589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Challenges of fast sampling of volatiles for thermal desorption gas chromatography - mass spectrometry.
    Marcillo A; Weiß BM; Widdig A; Birkemeyer C
    J Chromatogr A; 2020 Apr; 1617():460822. PubMed ID: 31928772
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of different adsorbents for large-volume pre-concentration for analyzing atmospheric persistent organic pollutants at trace levels.
    Avino P; Cinelli G; Notardonato I; Russo MV
    Anal Bioanal Chem; 2011 Jul; 400(10):3561-71. PubMed ID: 21553216
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Needle microextraction trap for on-site analysis of airborne volatile compounds at ultra-trace levels in gaseous samples.
    Alonso M; Godayol A; Antico E; Sanchez JM
    J Sep Sci; 2011 Oct; 34(19):2705-11. PubMed ID: 21818851
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.