These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

806 related articles for article (PubMed ID: 24054767)

  • 1. Complications of endoscopic ultrasound fine needle aspiration on pancreatic cystic lesions: final results from a large prospective multicenter study.
    Tarantino I; Fabbri C; Di Mitri R; Pagano N; Barresi L; Mocciaro F; Maimone A; Curcio G; Repici A; Traina M
    Dig Liver Dis; 2014 Jan; 46(1):41-4. PubMed ID: 24054767
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasound-guided fine needle aspiration and biopsy using a 22-gauge needle with side fenestration in pancreatic cystic lesions.
    Barresi L; Tarantino I; Traina M; Granata A; Curcio G; Azzopardi N; Baccarini P; Liotta R; Fornelli A; Maimone A; Jovine E; Cennamo V; Fabbri C
    Dig Liver Dis; 2014 Jan; 46(1):45-50. PubMed ID: 23916241
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Contrast Harmonic-Endoscopic Ultrasound Is Useful to Identify Neoplastic Features of Pancreatic Cysts (With Videos).
    Fusaroli P; Serrani M; De Giorgio R; D'Ercole MC; Ceroni L; Lisotti A; Caletti G
    Pancreas; 2016 Feb; 45(2):265-8. PubMed ID: 26474428
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The role of endoscopic ultrasound and endoscopic ultrasound-guided fine-needle aspiration in distinguishing pancreatic cystic lesions.
    Moparty B; Logroño R; Nealon WH; Waxman I; Raju GS; Pasricha PJ; Bhutani MS
    Diagn Cytopathol; 2007 Jan; 35(1):18-25. PubMed ID: 17173300
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of endoscopic ultrasound-guided fine-needle aspiration on incidental pancreatic cysts. A prospective study.
    Ardengh JC; Lopes CV; de Lima-Filho ER; Kemp R; Dos Santos JS
    Scand J Gastroenterol; 2014 Jan; 49(1):114-20. PubMed ID: 24188361
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility and safety of microforceps biopsy in the diagnosis of pancreatic cysts.
    Basar O; Yuksel O; Yang DJ; Samarasena J; Forcione D; DiMaio CJ; Wagh MS; Chang K; Casey B; Fernandez-Del Castillo C; Pitman MB; Brugge WR
    Gastrointest Endosc; 2018 Jul; 88(1):79-86. PubMed ID: 29510146
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoscopic ultrasonography (EUS) and EUS-guided fine-needle aspiration with cyst fluid analysis in pancreatic cystic neoplasms.
    Repák R; Rejchrt S; Bártová J; Malírová E; Tycová V; Bures J
    Hepatogastroenterology; 2009; 56(91-92):629-35. PubMed ID: 19621669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical feasibility, diagnostic yield, and safety of microforceps biopsies during EUS evaluation of pancreatic cystic lesions (with video).
    Mittal C; Obuch JC; Hammad H; Edmundowicz SA; Wani S; Shah RJ; Brauer BC; Attwell AR; Kaplan JB; Wagh MS
    Gastrointest Endosc; 2018 May; 87(5):1263-1269. PubMed ID: 29309781
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endoscopic ultrasound and fine needle aspiration in inflammatory and cystic pancreatic pathology.
    Vazquez-Sequeiros E
    Minerva Med; 2007 Aug; 98(4):357-60. PubMed ID: 17921950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic yield of endoscopic ultrasound with fine-needle aspiration in pancreatic cystic lesions.
    Argüello L; Sánchez-Montes C; Mansilla-Vivar R; Artés J; Prieto M; Alonso-Lázaro N; Satorres-Paniagua C; Pons-Beltrán V
    Gastroenterol Hepatol; 2020 Jan; 43(1):1-8. PubMed ID: 31753518
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cystic pancreatic neuroendocrine tumors: endoscopic ultrasound and fine-needle aspiration characteristics.
    Yoon WJ; Daglilar ES; Pitman MB; Brugge WR
    Endoscopy; 2013; 45(3):189-94. PubMed ID: 23296363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel approach to the diagnosis of pancreatic serous cystadenoma: needle-based confocal laser endomicroscopy.
    Napoléon B; Lemaistre AI; Pujol B; Caillol F; Lucidarme D; Bourdariat R; Morellon-Mialhe B; Fumex F; Lefort C; Lepilliez V; Palazzo L; Monges G; Filoche B; Giovannini M
    Endoscopy; 2015 Jan; 47(1):26-32. PubMed ID: 25325684
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of endoscopic ultrasound-guided fine needle aspiration cytology on the differentiation of malignant and benign pancreatic cystic lesions: a single-center experience.
    Oguz D; Öztaş E; Kalkan IH; Tayfur O; Cicek B; Aydog G; Kurt M; Beyazit Y; Etik D; Nadir I; Sahin B
    J Dig Dis; 2013 Mar; 14(3):132-9. PubMed ID: 23167591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High and low negative pressure suction techniques in EUS-guided fine-needle tissue acquisition by using 25-gauge needles: a multicenter, prospective, randomized, controlled trial.
    Kudo T; Kawakami H; Hayashi T; Yasuda I; Mukai T; Inoue H; Katanuma A; Kawakubo K; Ishiwatari H; Doi S; Yamada R; Maguchi H; Isayama H; Mitsuhashi T; Sakamoto N;
    Gastrointest Endosc; 2014 Dec; 80(6):1030-7.e1. PubMed ID: 24890422
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic error assessment and associated harm of endoscopic ultrasound-guided fine-needle aspiration of neuroendocrine neoplasms of the pancreas.
    Hooper K; Mukhtar F; Li S; Eltoum IA
    Cancer Cytopathol; 2013 Nov; 121(11):653-60. PubMed ID: 23839928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Needle Tract Seeding: An Overlooked Rare Complication of Endoscopic Ultrasound-Guided Fine-Needle Aspiration.
    Minaga K; Takenaka M; Katanuma A; Kitano M; Yamashita Y; Kamata K; Yamao K; Watanabe T; Maguchi H; Kudo M
    Oncology; 2017; 93 Suppl 1():107-112. PubMed ID: 29258068
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incidents and adverse events of endoscopic ultrasound-guided fine-needle aspiration for pancreatic cystic lesions.
    Du C; Chai NL; Linghu EQ; Li HK; Sun YF; Xu W; Wang XD; Tang P; Yang J
    World J Gastroenterol; 2017 Aug; 23(30):5610-5618. PubMed ID: 28852320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Factors determining diagnostic yield of endoscopic ultrasound guided fine-needle aspiration for pancreatic cystic lesions: a multicentre Asian study.
    Lim LG; Lakhtakia S; Ang TL; Vu CK; Dy F; Chong VH; Khor CJ; Lim WC; Doshi BK; Varadarajulu S; Yasuda K; Wong JY; Chan YH; Nga ME; Ho KY;
    Dig Dis Sci; 2013 Jun; 58(6):1751-7. PubMed ID: 23314918
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnostic performance of endoscopic ultrasound (EUS)/endoscopic ultrasound--fine needle aspiration (EUS-FNA) cytology in solid and cystic pancreatic neuroendocrine tumours.
    Mitra V; Nayar MK; Leeds JS; Wadehra V; Haugk B; Scott J; Charnley RM; Oppong KW
    J Gastrointestin Liver Dis; 2015 Mar; 24(1):69-75. PubMed ID: 25822436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Serous cystadenoma of the pancreas: limitations and pitfalls of endoscopic ultrasound-guided fine-needle aspiration biopsy.
    Belsley NA; Pitman MB; Lauwers GY; Brugge WR; Deshpande V
    Cancer; 2008 Apr; 114(2):102-10. PubMed ID: 18260088
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.