131 related articles for article (PubMed ID: 24070671)
1. Micro-CT image reconstruction based on alternating direction augmented Lagrangian method and total variation.
Gopi VP; Palanisamy P; Wahid KA; Babyn P; Cooper D
Comput Med Imaging Graph; 2013; 37(7-8):419-29. PubMed ID: 24070671
[TBL] [Abstract][Full Text] [Related]
2. Efficient and robust 3D CT image reconstruction based on total generalized variation regularization using the alternating direction method.
Chen J; Wang L; Yan B; Zhang H; Cheng G
J Xray Sci Technol; 2015; 23(6):683-99. PubMed ID: 26756406
[TBL] [Abstract][Full Text] [Related]
3. Distributed CT image reconstruction algorithm based on the alternating direction method.
Wang L; Cai A; Zhang H; Yan B; Li L; Hu G; Bao S
J Xray Sci Technol; 2015; 23(1):83-99. PubMed ID: 25567409
[TBL] [Abstract][Full Text] [Related]
4. Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.
Qi H; Chen Z; Guo J; Zhou L
Biomed Mater Eng; 2015; 26 Suppl 1():S1389-98. PubMed ID: 26405900
[TBL] [Abstract][Full Text] [Related]
5. NUFFT-Based Iterative Image Reconstruction via Alternating Direction Total Variation Minimization for Sparse-View CT.
Yan B; Jin Z; Zhang H; Li L; Cai A
Comput Math Methods Med; 2015; 2015():691021. PubMed ID: 26120355
[TBL] [Abstract][Full Text] [Related]
6. An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.
Li J; Niu S; Huang J; Bian Z; Feng Q; Yu G; Liang Z; Chen W; Ma J
PLoS One; 2015; 10(10):e0140579. PubMed ID: 26495975
[TBL] [Abstract][Full Text] [Related]
7. A CT reconstruction approach from sparse projection with adaptive-weighted diagonal total-variation in biomedical application.
Deng L; Mi D; He P; Feng P; Yu P; Chen M; Li Z; Wang J; Wei B
Biomed Mater Eng; 2015; 26 Suppl 1():S1685-93. PubMed ID: 26405935
[TBL] [Abstract][Full Text] [Related]
8. Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.
Liu Y; Shangguan H; Zhang Q; Zhu H; Shu H; Gui Z
Comput Biol Med; 2015 May; 60():117-31. PubMed ID: 25817533
[TBL] [Abstract][Full Text] [Related]
9. Compressed sensing MRI via fast linearized preconditioned alternating direction method of multipliers.
Chen S; Du H; Wu L; Jin J; Qiu B
Biomed Eng Online; 2017 Apr; 16(1):53. PubMed ID: 28449672
[TBL] [Abstract][Full Text] [Related]
10. System matrix analysis for sparse-view iterative image reconstruction in X-ray CT.
Wang L; Zhang H; Cai A; Li Y; Yan B; Li L; Hu G
J Xray Sci Technol; 2015; 23(1):1-10. PubMed ID: 25567402
[TBL] [Abstract][Full Text] [Related]
11. Introduction of an effective method for the optimization of CT protocols using iterative reconstruction algorithms: comparison with patient data.
Kordolaimi SD; Saradeas I; Ploussi A; Pantos I; Argentos S; Efstathopoulos EP
AJR Am J Roentgenol; 2014 Oct; 203(4):W434-9. PubMed ID: 25247973
[TBL] [Abstract][Full Text] [Related]
12. Tomographic image reconstruction via estimation of sparse unidirectional gradients.
Polak AG; Mroczka J; WysoczaĆski D
Comput Biol Med; 2017 Feb; 81():93-105. PubMed ID: 28027461
[TBL] [Abstract][Full Text] [Related]
13. An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography.
Fu J; Schleede S; Tan R; Chen L; Bech M; Achterhold K; Gifford M; Loewen R; Ruth R; Pfeiffer F
Z Med Phys; 2013 Sep; 23(3):186-93. PubMed ID: 23199611
[TBL] [Abstract][Full Text] [Related]
14. Low-dose CT statistical iterative reconstruction via modified MRF regularization.
Shangguan H; Zhang Q; Liu Y; Cui X; Bai Y; Gui Z
Comput Methods Programs Biomed; 2016 Jan; 123():129-41. PubMed ID: 26542474
[TBL] [Abstract][Full Text] [Related]
15. Smoothly clipped absolute deviation (SCAD) regularization for compressed sensing MRI using an augmented Lagrangian scheme.
Mehranian A; Rad HS; Rahmim A; Ay MR; Zaidi H
Magn Reson Imaging; 2013 Oct; 31(8):1399-411. PubMed ID: 23891179
[TBL] [Abstract][Full Text] [Related]
16. CT Image Reconstruction from Sparse Projections Using Adaptive TpV Regularization.
Qi H; Chen Z; Zhou L
Comput Math Methods Med; 2015; 2015():354869. PubMed ID: 26089962
[TBL] [Abstract][Full Text] [Related]
17. A preliminary investigation of local tomography for megavoltage CT imaging.
Anastasio MA; Shi D; Pan X; Pelizzari C; Munro P
Med Phys; 2003 Nov; 30(11):2969-80. PubMed ID: 14655944
[TBL] [Abstract][Full Text] [Related]
18. Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization.
Cai A; Wang L; Zhang H; Yan B; Li L; Xi X; Li J
J Xray Sci Technol; 2014; 22(3):335-49. PubMed ID: 24865209
[TBL] [Abstract][Full Text] [Related]
19. Total variation minimization approach in in-line x-ray phase-contrast tomography.
Kostenko A; Batenburg KJ; King A; Offerman SE; van Vliet LJ
Opt Express; 2013 May; 21(10):12185-96. PubMed ID: 23736439
[TBL] [Abstract][Full Text] [Related]
20. Geometry-constraint-scan imaging for in-line phase contrast micro-CT.
Fu J; Yu G; Fan D
Biomed Mater Eng; 2014; 24(6):3105-11. PubMed ID: 25227019
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]