These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
346 related articles for article (PubMed ID: 24078934)
1. A simple method to improve adenoma detection rate during colonoscopy: altering patient position. Köksal AŞ; Kalkan IH; Torun S; Taşkıran I; Öztaş E; Kayaçetin E; Şaşmaz N Can J Gastroenterol; 2013 Sep; 27(9):509-12. PubMed ID: 24078934 [TBL] [Abstract][Full Text] [Related]
2. Dynamic patient position changes during colonoscope withdrawal increase adenoma detection: a randomized, crossover trial. East JE; Bassett P; Arebi N; Thomas-Gibson S; Guenther T; Saunders BP Gastrointest Endosc; 2011 Mar; 73(3):456-63. PubMed ID: 20950801 [TBL] [Abstract][Full Text] [Related]
3. Position change during colonoscope withdrawal increases polyp and adenoma detection in the right but not in the left side of the colon: results of a randomized controlled trial. Ball AJ; Johal SS; Riley SA Gastrointest Endosc; 2015 Sep; 82(3):488-94. PubMed ID: 25910661 [TBL] [Abstract][Full Text] [Related]
4. Polyp and adenoma detection rates in the proximal and distal colon. Boroff ES; Gurudu SR; Hentz JG; Leighton JA; Ramirez FC Am J Gastroenterol; 2013 Jun; 108(6):993-9. PubMed ID: 23567353 [TBL] [Abstract][Full Text] [Related]
6. Effect of Dynamic Position Changes on Adenoma Detection During Colonoscope Withdrawal: A Randomized Controlled Multicenter Trial. Lee SW; Chang JH; Ji JS; Maeong IH; Cheung DY; Kim JS; Cho YS; Chung WJ; Lee BI; Kim SW; Kim BW; Choi H; Choi MG Am J Gastroenterol; 2016 Jan; 111(1):63-9. PubMed ID: 26526085 [TBL] [Abstract][Full Text] [Related]
7. Relationship between the endoscopic withdrawal time and adenoma/polyp detection rate in individual colonic segments: a KASID multicenter study. Jung Y; Joo YE; Kim HG; Jeon SR; Cha JM; Yang HJ; Kim JW; Lee J; Kim KO; Song HK; Hwangbo Y; Shin JE Gastrointest Endosc; 2019 Mar; 89(3):523-530. PubMed ID: 30267654 [TBL] [Abstract][Full Text] [Related]
8. Right-sided adenoma detection with retroflexion versus forward-view colonoscopy. Chandran S; Parker F; Vaughan R; Mitchell B; Fanning S; Brown G; Yu J; Efthymiou M Gastrointest Endosc; 2015 Mar; 81(3):608-13. PubMed ID: 25440687 [TBL] [Abstract][Full Text] [Related]
9. Impact of second forward-view examination on adenoma detection rate during unsedated colonoscopy: a randomized controlled trial. Shan K; Lu H; Zhang Z; Xie J; Xu L; Wang W; Hu C; Xu L BMC Gastroenterol; 2021 May; 21(1):213. PubMed ID: 33971824 [TBL] [Abstract][Full Text] [Related]
11. Timed screening colonoscopy: a randomized trial of two colonoscopic withdrawal techniques. Coghlan E; Laferrere L; Zenon E; Marini JM; Rainero G; San Roman A; Posadas Martinez ML; Nadales A Surg Endosc; 2020 Mar; 34(3):1200-1205. PubMed ID: 31144121 [TBL] [Abstract][Full Text] [Related]
12. Diagnostic yield of scope retroflexion in the right colon: A prospective cohort study. Triantafyllou K; Tziatzios G; Sioulas AD; Beintaris I; Gouloumi AR; Panayiotides IG; Dimitriadis GD Dig Liver Dis; 2016 Feb; 48(2):176-81. PubMed ID: 26748425 [TBL] [Abstract][Full Text] [Related]
13. Effect of dynamic position changes during colonoscope withdrawal: a meta-analysis of randomized controlled trials. Li P; Ma B; Gong S; Zhang X; Li W Surg Endosc; 2021 Mar; 35(3):1171-1181. PubMed ID: 32128607 [TBL] [Abstract][Full Text] [Related]
14. Yield of repeat forward-view examination of the right side of the colon in screening and surveillance colonoscopy. Clark BT; Parikh ND; Laine L Gastrointest Endosc; 2016 Jul; 84(1):126-32. PubMed ID: 26769408 [TBL] [Abstract][Full Text] [Related]
15. A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection. Ou G; Kim E; Lakzadeh P; Tong J; Enns R; Ramji A; Whittaker S; Ko HH; Bressler B; Halparin L; Lam E; Amar J; Telford J Gastrointest Endosc; 2014 Aug; 80(2):277-83. PubMed ID: 24629419 [TBL] [Abstract][Full Text] [Related]
16. [Usefulness of polyp and adenoma detection rate in the proximal and distal colon]. Choi SY; Park DI; Lee CK; Cha JM; Lee SH; Whangbo Y; Eun CS; Han DS; Lee BI; Shin JE Korean J Gastroenterol; 2014 Jan; 63(1):11-7. PubMed ID: 24463283 [TBL] [Abstract][Full Text] [Related]
17. Two vs One Forward View Examination of Right Colon on Adenoma Detection: An International Multicenter Randomized Trial. Tang RSY; Lee JWJ; Chang LC; Ong DEH; Chiu HM; Matsuda T; Kim HS; Sekiguchi M; Leong RW; Ho AMY; Lam TYT; Tse YK; Lin L; Yeoh KG; Lau JYW; Sung JJY; Clin Gastroenterol Hepatol; 2022 Feb; 20(2):372-380.e2. PubMed ID: 33065307 [TBL] [Abstract][Full Text] [Related]
18. Sedated Colonoscopy may not be Beneficial for Polyp/Adenoma Detection. Han J; Cao R; Su D; Li Y; Gao C; Wang K; Gao F; Qi X Cancer Control; 2024; 31():10732748241272482. PubMed ID: 39403995 [TBL] [Abstract][Full Text] [Related]
20. Improved detection of right colon adenomas with additional retroflexion following two forward-view examinations: a prospective study. Lee HS; Jeon SW; Park HY; Yeo SJ Endoscopy; 2017 Apr; 49(4):334-341. PubMed ID: 27931050 [No Abstract] [Full Text] [Related] [Next] [New Search]