These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 24079951)

  • 41. Comparison of performances of two commercially available tests, a PCR assay and a ligase chain reaction test, in detection of urogenital Chlamydia trachomatis infection.
    Puolakkainen M; Hiltunen-Back E; Reunala T; Suhonen S; Lähteenmäki P; Lehtinen M; Paavonen J
    J Clin Microbiol; 1998 Jun; 36(6):1489-93. PubMed ID: 9620366
    [TBL] [Abstract][Full Text] [Related]  

  • 42. High analytical sensitivity and low rates of inhibition may contribute to detection of Chlamydia trachomatis in significantly more women by the APTIMA Combo 2 assay.
    Chernesky M; Jang D; Luinstra K; Chong S; Smieja M; Cai W; Hayhoe B; Portillo E; Macritchie C; Main C; Ewert R
    J Clin Microbiol; 2006 Feb; 44(2):400-5. PubMed ID: 16455891
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Performance characteristics of the Becton Dickinson ProbeTec System for direct detection of Chlamydia trachomatis and Neisseria gonorrhoeae in male and female urine specimens in comparison with the Roche Cobas System.
    Chan EL; Brandt K; Olienus K; Antonishyn N; Horsman GB
    Arch Pathol Lab Med; 2000 Nov; 124(11):1649-52. PubMed ID: 11079018
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Prevalence of Chlamydia infection among women visiting a gynaecology outpatient department: evaluation of an in-house PCR assay for detection of Chlamydia trachomatis.
    Patel AL; Sachdev D; Nagpal P; Chaudhry U; Sonkar SC; Mendiratta SL; Saluja D
    Ann Clin Microbiol Antimicrob; 2010 Sep; 9():24. PubMed ID: 20822551
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Performance of the Atlas Genetics Rapid Test for Chlamydia trachomatis and Women's Attitudes Toward Point-Of-Care Testing.
    Widdice LE; Hsieh YH; Silver B; Barnes M; Barnes P; Gaydos CA
    Sex Transm Dis; 2018 Nov; 45(11):723-727. PubMed ID: 29771869
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Use of a single swab in multi-microbe or flex trans transport medium for detection of Chlamydia trachomatis by Roche Amplicor PCR and culture in specimens from two different patient populations.
    Fong CK; Falcone J; Landry ML
    J Clin Microbiol; 1997 Sep; 35(9):2427-9. PubMed ID: 9276433
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of self-collected glans and rectal swabs from men who have sex with men for detection of Chlamydia trachomatis and Neisseria gonorrhoeae by use of nucleic acid amplification tests.
    Moncada J; Schachter J; Liska S; Shayevich C; Klausner JD
    J Clin Microbiol; 2009 Jun; 47(6):1657-62. PubMed ID: 19369445
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Pooling of urine specimens for detection of asymptomatic Chlamydia trachomatis infections by PCR in a low-prevalence population: cost-saving strategy for epidemiological studies and screening programs.
    Morré SA; Meijer CJ; Munk C; Krüger-Kjaer S; Winther JF; Jørgensens HO; van Den Brule AJ
    J Clin Microbiol; 2000 Apr; 38(4):1679-80. PubMed ID: 10747169
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Evaluation of the Abbott RealTime CT/NG assay in comparison to the Roche Cobas Amplicor CT/NG assay.
    Cheng A; Qian Q; Kirby JE
    J Clin Microbiol; 2011 Apr; 49(4):1294-300. PubMed ID: 21325546
    [TBL] [Abstract][Full Text] [Related]  

  • 50.
    Rantakokko-Jalava K; Hokynar K; Hieta N; Keskitalo A; Jokela P; Muotiala A; Jokiranta TS; Kuusela R; Sarkkinen H; Aittoniemi J; Vuorinen T; Hakanen AJ; Puolakkainen M
    Euro Surveill; 2019 May; 24(22):. PubMed ID: 31164192
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Validation of the Roche COBAS Amplicor system for Chlamydia trachomatis.
    Matthews-Greer JM; McRae KL; LaHaye EB; Jamison RM
    Clin Lab Sci; 2001; 14(2):82-4. PubMed ID: 15625979
    [TBL] [Abstract][Full Text] [Related]  

  • 52. First report of performance of the Versant CT/GC DNA 1.0 assay (kPCR) for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
    Kerndt PR; Ferrero DV; Aynalem G; Monga D; Wang S; Zhang N; Wong C; Liggins M; Meng Q
    J Clin Microbiol; 2011 Apr; 49(4):1347-53. PubMed ID: 21307209
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Reproducibility problems with the AMPLICOR PCR Chlamydia trachomatis test.
    Peterson EM; Darrow V; Blanding J; Aarnaes S; de la Maza LM
    J Clin Microbiol; 1997 Apr; 35(4):957-9. PubMed ID: 9157161
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Evaluation of the Abbott LCx ligase chain reaction assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine and genital swab specimens from a sexually transmitted disease clinic population.
    Carroll KC; Aldeen WE; Morrison M; Anderson R; Lee D; Mottice S
    J Clin Microbiol; 1998 Jun; 36(6):1630-3. PubMed ID: 9620391
    [TBL] [Abstract][Full Text] [Related]  

  • 55. An assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.
    Leslie DE; Azzato F; Ryan N; Fyfe J
    Commun Dis Intell Q Rep; 2003; 27(3):373-9. PubMed ID: 14510065
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Multicenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis.
    Van Der Pol B; Quinn TC; Gaydos CA; Crotchfelt K; Schachter J; Moncada J; Jungkind D; Martin DH; Turner B; Peyton C; Jones RB
    J Clin Microbiol; 2000 Mar; 38(3):1105-12. PubMed ID: 10699004
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens.
    Tanaka M; Nakayama H; Sagiyama K; Haraoka M; Yoshida H; Hagiwara T; Akazawa K; Naito S
    J Clin Pathol; 2000 May; 53(5):350-4. PubMed ID: 10889816
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine.
    Goessens WH; Mouton JW; van der Meijden WI; Deelen S; van Rijsoort-Vos TH; Lemmens-den Toom N; Verbrugh HA; Verkooyen RP
    J Clin Microbiol; 1997 Oct; 35(10):2628-33. PubMed ID: 9316920
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Detection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture.
    Shattock RM; Patrizio C; Simmonds P; Sutherland S
    Sex Transm Infect; 1998 Aug; 74(4):289-93. PubMed ID: 9924472
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of an in-house PCR assay, direct fluorescence assay and the Roche AMPLICOR Chlamydia trachomatis kit for detection of C. trachomatis.
    Sachdeva P; Patel AL; Sachdev D; Ali M; Mittal A; Saluja D
    J Med Microbiol; 2009 Jul; 58(Pt 7):867-873. PubMed ID: 19502371
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.