These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 24083049)
1. Comparison of thermal coagulation profiles for bipolar forceps with different cooling mechanisms in a porcine model of spinal surgery. Chen RK; Than KD; Wang AC; Park P; Shih AJ Surg Neurol Int; 2013; 4():113. PubMed ID: 24083049 [TBL] [Abstract][Full Text] [Related]
2. Thermal damage assessment of novel bipolar forceps in a sheep model of spinal surgery. Elliott-Lewis EW; Jolette J; Ramos J; Benzel EC Neurosurgery; 2010 Jul; 67(1):166-71; discussion 171-2. PubMed ID: 20568670 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a new bipolar coagulation forceps in a thermal damage assessment. Elliott-Lewis EW; Mason AM; Barrow DL Neurosurgery; 2009 Dec; 65(6):1182-7; discussion 1187. PubMed ID: 19934979 [TBL] [Abstract][Full Text] [Related]
5. Thermal properties of contemporary bipolar systems using infrared imaging. Keshavarzi S; Bolour A; Yarbrough C; Mendez K; Behrouzi B; Kasasbeh AS; Levy ML World Neurosurg; 2015 Mar; 83(3):376-81. PubMed ID: 25463420 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of Bone Wax Coated Bipolar Coagulation Forceps: Performance and Safety Assessment. Shi J; Wei W; Wang Z; Ren H; Jia C; Dong L; Li Z; Zhang J; Feng Y; Huang K; Li X; Chen J Front Surg; 2021; 8():816295. PubMed ID: 35127808 [TBL] [Abstract][Full Text] [Related]
7. Bumping phenomenon during continuous coagulation with bipolar forceps. Mikami T; Wanibuchi M; Mikuni N Neurol Med Chir (Tokyo); 2012; 52(10):731-5. PubMed ID: 23095265 [TBL] [Abstract][Full Text] [Related]
8. Performance of bipolar forceps during coagulation and its dependence on the tip material: a quantitative experimental assay. Technical note. Mikami T; Takahashi A; Hashi K; Gasa S; Houkin K J Neurosurg; 2004 Jan; 100(1):133-8. PubMed ID: 14743926 [TBL] [Abstract][Full Text] [Related]
9. Efficacy of colonic submucosal saline solution injection for the reduction of iatrogenic thermal injury. Norton ID; Wang L; Levine SA; Burgart LJ; Hofmeister EK; Rumalla A; Gostout CJ; Petersen BT Gastrointest Endosc; 2002 Jul; 56(1):95-9. PubMed ID: 12085042 [TBL] [Abstract][Full Text] [Related]
10. Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery. Hefermehl LJ; Largo RA; Hermanns T; Poyet C; Sulser T; Eberli D BJU Int; 2014 Aug; 114(2):245-52. PubMed ID: 24127773 [TBL] [Abstract][Full Text] [Related]
11. Antiadhesion Function between a Biological Surface and a Metallic Device Interface at High Temperature by Wettability Control. Park JY; Tenjimbayashi M; Muto J; Shiratori S ACS Biomater Sci Eng; 2018 May; 4(5):1891-1899. PubMed ID: 33445344 [TBL] [Abstract][Full Text] [Related]
12. Thermoelectrical modeling of bipolar coagulation on posterior spinal artery in a porcine spinal surgery model. Chen RK; Than KD; Park P; Shih AJ IEEE Trans Biomed Eng; 2014 Jan; 61(1):182-8. PubMed ID: 23963190 [TBL] [Abstract][Full Text] [Related]
13. Comparatıve assessment of thermal ınjury ınduced by bıpolar electrocautery systems ın a porcıne model. Roy AK; Turan N; Wangmo P; Nkrumah L; Neill SG; Pradilla G Surg Neurol Int; 2021; 12():146. PubMed ID: 33948316 [TBL] [Abstract][Full Text] [Related]
14. A Method to Facilitate "Nonsticking" of Regular Bipolar Forceps. Huang HK; Wang JP J Hand Microsurg; 2017 Aug; 9(2):113-114. PubMed ID: 28867916 [TBL] [Abstract][Full Text] [Related]
15. Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler™ during thyroidectomy. Brzeziński J; Kałużna-Markowska K; Naze M; Stróżyk G; Dedecjus M Pol Przegl Chir; 2011 Jul; 83(7):355-60. PubMed ID: 22166662 [TBL] [Abstract][Full Text] [Related]
16. Isotonic mannitol and the prevention of local heat generation and tissue adherence to bipolar diathermy forceps tips during electrical coagulation. Technical note. Sakatani K; Ohtaki M; Morimoto S; Hashi K J Neurosurg; 1995 Apr; 82(4):669-71. PubMed ID: 7897536 [TBL] [Abstract][Full Text] [Related]
17. Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic Scalpel and the Ligasure. Sutton PA; Awad S; Perkins AC; Lobo DN Br J Surg; 2010 Mar; 97(3):428-33. PubMed ID: 20101674 [TBL] [Abstract][Full Text] [Related]
18. Efficacy of hemostasis for epidural venous plexus and safety for neural structure using soft coagulation system in spinal surgery: a laboratory investigation using a porcine model. Nishida K; Kakutani K; Maeno K; Takada T; Yurube T; Kuroda R; Kurosaka M J Spinal Disord Tech; 2013 Oct; 26(7):E281-5. PubMed ID: 23381179 [TBL] [Abstract][Full Text] [Related]
19. Prevention of Nerve Root Thermal Injury Caused by Bipolar Cauterization Near the Nerve Roots. Ohyama S; Takahashi S; Tamai K; Hori Y; Hirakawa Y; Hoshino M; Suzuki A; Nakamura H Spine (Phila Pa 1976); 2019 Mar; 44(6):E321-E328. PubMed ID: 30130335 [TBL] [Abstract][Full Text] [Related]
20. Bipolar coagulation with small diameter forceps in animal models for in-utero cord obliteration. Yesildaglar N; Zikulnig L; Gratacós E; Devlieger R; Schröder HJ; Deprest J; Hecher K Hum Reprod; 2000 Apr; 15(4):865-8. PubMed ID: 10739834 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]