These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
337 related articles for article (PubMed ID: 24088904)
1. VADoscopy: a novel intraoperative technique to evaluate HeartMate II left ventricular assist device inflow obstruction and thrombosis. Cheng A; Swartz MF; Massey HT ASAIO J; 2013; 59(6):671-4. PubMed ID: 24088904 [TBL] [Abstract][Full Text] [Related]
2. The axial continuous-flow blood pump: Bench evaluation of changes in flow associated with changes of inflow cannula angle. Karimov JH; Zhen-Yu Tong M; Byram N; Sunagawa G; Dessoffy R; Moazami N; Starling RC; Fukamachi K J Heart Lung Transplant; 2017 Jan; 36(1):106-112. PubMed ID: 28029574 [TBL] [Abstract][Full Text] [Related]
3. Utility of cardiac computed tomography for inflow cannula patency assessment and prediction of clinical outcome in patients with the HeartMate II left ventricular assist device. Sacks J; Gonzalez-Stawinski GV; Hall S; Lima B; MacHannaford J; Dockery W; Cura M; Chamogeorgakis T Interact Cardiovasc Thorac Surg; 2015 Nov; 21(5):590-3. PubMed ID: 26223857 [TBL] [Abstract][Full Text] [Related]
4. Role of computed tomography angiography for HeartMate II left ventricular assist device thrombosis. Yu SN; Han J; Takeda K; Ginns JN; Kurlansky PA; Garan AR; Yuzefpolskaya M; Topkara VK; Colombo PC; Naka Y; Takayama H Int J Artif Organs; 2018 Jun; 41(6):325-332. PubMed ID: 29562790 [TBL] [Abstract][Full Text] [Related]
5. Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. Laumen M; Kaufmann T; Timms D; Schlanstein P; Jansen S; Gregory S; Wong KC; Schmitz-Rode T; Steinseifer U Artif Organs; 2010 Oct; 34(10):798-806. PubMed ID: 20964698 [TBL] [Abstract][Full Text] [Related]
6. Association of Inflow Cannula Position with Left Ventricular Unloading and Clinical Outcomes in Patients with HeartMate II Left Ventricular Assist Device. Imamura T; Nguyen A; Chung B; Rodgers D; Sarswat N; Kim G; Raikhelkar J; Adatya S; Ota T; Song T; Juricek C; Estep JD; Burkhoff D; Jeevanandam V; Sayer G; Uriel N ASAIO J; 2019; 65(4):331-335. PubMed ID: 29933250 [TBL] [Abstract][Full Text] [Related]
7. Surgical technique influences HeartMate II left ventricular assist device thrombosis. Taghavi S; Ward C; Jayarajan SN; Gaughan J; Wilson LM; Mangi AA Ann Thorac Surg; 2013 Oct; 96(4):1259-1265. PubMed ID: 23968757 [TBL] [Abstract][Full Text] [Related]
9. Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices. Sorensen EN; Kon ZN; Feller ED; Pham SM; Griffith BP Ann Thorac Surg; 2018 May; 105(5):1377-1383. PubMed ID: 29305851 [TBL] [Abstract][Full Text] [Related]
10. Left Ventricular Assist Device Inflow Angle and Pump Positional Change Over Time Adverse Impact on Left Ventricular Assist Device Function. Kazui T; Zhang A; Greenberg J; Itoh A; Tran PL; Keith AD; Ewald GA; Damiano RJ; Silvestry SC Ann Thorac Surg; 2016 Dec; 102(6):1933-1940. PubMed ID: 27469340 [TBL] [Abstract][Full Text] [Related]
11. Left ventricular assist device inflow cannula thrombus: characterization with two-dimensional transthoracic echocardiography. Missov E ASAIO J; 2013; 59(6):662-3. PubMed ID: 24172272 [TBL] [Abstract][Full Text] [Related]
12. Left Ventricular Assist Device Thrombosis Is Associated With an Increase in the Systolic-to-Diastolic Velocity Ratio Measured at the Inflow and Outflow Cannulae. Jain A; Rohrer B; Gebhardt B; Breeze JL; Quick JD; Couper G; Kiernan MS; Lawrence M; Cobey FC J Cardiothorac Vasc Anesth; 2017 Apr; 31(2):497-504. PubMed ID: 28216204 [TBL] [Abstract][Full Text] [Related]
13. Principles of HeartMate II implantation to avoid pump malposition and migration. Adamson RM; Mangi AA; Kormos RL; Farrar DJ; Dembitsky WP J Card Surg; 2015 Mar; 30(3):296-9. PubMed ID: 25472467 [TBL] [Abstract][Full Text] [Related]
14. Factors Related to Pump Thrombosis With the Heartmate II Left Ventricular Assist Device. Klodell CT; Massey HT; Adamson RM; Dean DA; Horstmanshof DA; Ransom JM; Salerno CT; Cowger JA; Aranda JM; Chen L; Long JW; Dembitsky W J Card Surg; 2015 Oct; 30(10):775-80. PubMed ID: 26283153 [TBL] [Abstract][Full Text] [Related]
15. Thrombus on the inflow cannula of the HeartWare HVAD: an update. Glass CH; Christakis A; Fishbein GA; Watkins JC; Strickland KC; Mitchell RN; Padera RF Cardiovasc Pathol; 2019; 38():14-20. PubMed ID: 30399526 [TBL] [Abstract][Full Text] [Related]
16. HeartMate II Left Ventricular Assist Device Geometry on Chest Radiograph Does Not Correlate with Risk of Pump Thrombosis. Han JJ; Gaffey AC; Sooppan R; Hung G; Venkataraman C; Phillips E; Howard J; McLean R; Acker MA; Atluri P ASAIO J; 2016; 62(2):128-32. PubMed ID: 26720737 [TBL] [Abstract][Full Text] [Related]
17. Urgent pump exchange for stroke resulting from a distorted HeartMate XVE inflow conduit. Frazier OH; Forrester MD; Gemmato C; Gregoric ID J Heart Lung Transplant; 2007 Jun; 26(6):646-8. PubMed ID: 17543792 [TBL] [Abstract][Full Text] [Related]
18. In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery. Hanke JS; Krabatsch T; Rojas SV; Deniz E; Ismail I; Martens A; Shrestha M; Haverich A; Netuka I; Schmitto JD Artif Organs; 2017 Mar; 41(3):272-275. PubMed ID: 27087560 [TBL] [Abstract][Full Text] [Related]
19. Inflow cannula obstruction of the HeartWare left ventricular assist device: what do we really know? Pappalardo F; Bertoldi LF; Sanvito F; Marini C; Consolo F Cardiovasc Pathol; 2021; 50():107299. PubMed ID: 33080399 [TBL] [Abstract][Full Text] [Related]
20. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD. May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]