These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Influence of intensity loss in the cavity of a folded Fabry-Perot interferometer on interferometric signals. Shyu LH; Chang CP; Wang YC Rev Sci Instrum; 2011 Jun; 82(6):063103. PubMed ID: 21721670 [TBL] [Abstract][Full Text] [Related]
4. Fabry-Pérot interferometer utilized for displacement measurement in a large measuring range. Wang YC; Shyu LH; Chang CP Rev Sci Instrum; 2010 Sep; 81(9):093102. PubMed ID: 20886971 [TBL] [Abstract][Full Text] [Related]
5. Optical fiber sensing with a low-finesse Fabry-Perot cavity. Santos JL; Leite AP; Jackson DA Appl Opt; 1992 Dec; 31(34):7361-6. PubMed ID: 20802607 [TBL] [Abstract][Full Text] [Related]
8. Subnanometer absolute displacement measurement using a frequency comb referenced dual resonance tracking Fabry-Perot interferometer. Zhu M; Wei H; Zhao S; Wu X; Li Y Appl Opt; 2015 May; 54(14):4594-601. PubMed ID: 25967521 [TBL] [Abstract][Full Text] [Related]
9. A Hot-Polymer Fiber Fabry-Perot Interferometer Anemometer for Sensing Airflow. Lee CL; Liu KW; Luo SH; Wu MS; Ma CT Sensors (Basel); 2017 Sep; 17(9):. PubMed ID: 28869510 [TBL] [Abstract][Full Text] [Related]
10. Experimental study of the effect of surface defects on the finesse and contrast of a Fabry-Perot interferometer. Palik ED; Boukari H; Gammon RW Appl Opt; 1996 Jan; 35(1):38-50. PubMed ID: 21068975 [TBL] [Abstract][Full Text] [Related]
11. Optical fiber Fabry-Perot interferometer cavity fabricated by femtosecond laser micromachining and fusion splicing for refractive index sensing. Liao CR; Hu TY; Wang DN Opt Express; 2012 Sep; 20(20):22813-8. PubMed ID: 23037431 [TBL] [Abstract][Full Text] [Related]
12. Fabry-Pérot resonator: spectral line shapes, generic and related Airy distributions, linewidths, finesses, and performance at low or frequency-dependent reflectivity. Ismail N; Kores CC; Geskus D; Pollnau M Opt Express; 2016 Jul; 24(15):16366-89. PubMed ID: 27464090 [TBL] [Abstract][Full Text] [Related]
13. Spatially continuous distributed fiber optic sensing using optical carrier based microwave interferometry. Huang J; Lan X; Luo M; Xiao H Opt Express; 2014 Jul; 22(15):18757-69. PubMed ID: 25089493 [TBL] [Abstract][Full Text] [Related]
14. Low-Finesse Fabry-Pérot Interferometers Applied in the Study of the Relation between the Optical Path Difference and Poles Location. Guillen Bonilla JT; Guillen Bonilla H; Rodríguez Betancourtt VM; Sánchez Morales ME; Gómez JR; Zamora AC; Guillen Bonilla A Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31941162 [TBL] [Abstract][Full Text] [Related]
15. Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers. Majchrowicz D; Hirsch M; Wierzba P; Bechelany M; Viter R; Jędrzejewska-Szczerska M Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 27011188 [TBL] [Abstract][Full Text] [Related]
16. Decoding the spectra of low-finesse extrinsic optical fiber Fabry-Perot interferometers. Ma C; Dong B; Gong J; Wang A Opt Express; 2011 Nov; 19(24):23727-42. PubMed ID: 22109399 [TBL] [Abstract][Full Text] [Related]
17. Dynamics of a noncontacting, white light Fabry-Perot interferometric displacement sensor. Moro EA; Todd MD; Puckett AD Appl Opt; 2012 Jul; 51(19):4394-402. PubMed ID: 22772112 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous measurement of pressure and temperature by employing Fabry-Perot interferometer based on pendant polymer droplet. Sun B; Wang Y; Qu J; Liao C; Yin G; He J; Zhou J; Tang J; Liu S; Li Z; Liu Y Opt Express; 2015 Feb; 23(3):1906-11. PubMed ID: 25836063 [TBL] [Abstract][Full Text] [Related]
19. Analytical model for low finesse, external cavity, fiber Fabry-Perot interferometers including multiple reflections and angular misalignment. Wilkinson PR; Pratt JR Appl Opt; 2011 Aug; 50(23):4671-80. PubMed ID: 21833146 [TBL] [Abstract][Full Text] [Related]