These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 24089877)

  • 1. Note: Determination of torsional spring constant of atomic force microscopy cantilevers: combining normal spring constant and classical beam theory.
    Álvarez-Asencio R; Thormann E; Rutland MW
    Rev Sci Instrum; 2013 Sep; 84(9):096102. PubMed ID: 24089877
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers.
    Yeh MK; Tai NH; Chen BY
    Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers.
    Li R; Ye H; Zhang W; Ma G; Su Y
    Sci Rep; 2015 Oct; 5():15828. PubMed ID: 26510769
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design of V-shaped cantilevers for enhanced multifrequency AFM measurements.
    Damircheli M; Eslami B
    Beilstein J Nanotechnol; 2020; 11():1525-1541. PubMed ID: 33094086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever.
    Yeh MK; Tai NH; Chen BY
    Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precise and direct method for the measurement of the torsion spring constant of the atomic force microscopy cantilevers.
    Jarząbek DM
    Rev Sci Instrum; 2015 Jan; 86(1):013701. PubMed ID: 25638084
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry.
    Gates RS; Pratt JR
    Nanotechnology; 2012 Sep; 23(37):375702. PubMed ID: 22922668
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Ultramicroscopy; 2013 Aug; 131():46-55. PubMed ID: 23685172
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accurate spring constant calibration for very stiff atomic force microscopy cantilevers.
    Grutzik SJ; Gates RS; Gerbig YB; Smith DT; Cook RF; Zehnder AT
    Rev Sci Instrum; 2013 Nov; 84(11):113706. PubMed ID: 24289403
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lateral force calibration for atomic force microscope cantilevers using a suspended nanowire.
    Zhang G; Li P; Wei D; Hu K; Qiu X
    Nanotechnology; 2020 Nov; 31(47):475703. PubMed ID: 32885790
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spring constant calibration of atomic force microscopy cantilevers with a piezosensor transfer standard.
    Langlois ED; Shaw GA; Kramar JA; Pratt JR; Hurley DC
    Rev Sci Instrum; 2007 Sep; 78(9):093705. PubMed ID: 17902953
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.
    Sader JE; Lu J; Mulvaney P
    Rev Sci Instrum; 2014 Nov; 85(11):113702. PubMed ID: 25430115
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid.
    Pettersson T; Nordgren N; Rutland MW; Feiler A
    Rev Sci Instrum; 2007 Sep; 78(9):093702. PubMed ID: 17902950
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Note: spring constant calibration of nanosurface-engineered atomic force microscopy cantilevers.
    Ergincan O; Palasantzas G; Kooi BJ
    Rev Sci Instrum; 2014 Feb; 85(2):026118. PubMed ID: 24593418
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterizing the free and surface-coupled vibrations of heated-tip atomic force microscope cantilevers.
    Killgore JP; Tung RC; Hurley DC
    Nanotechnology; 2014 Aug; 25(34):345701. PubMed ID: 25098183
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Nanotechnology; 2013 Jan; 24(1):015710. PubMed ID: 23220746
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope.
    Rawlings C; Durkan C
    Nanotechnology; 2012 Dec; 23(48):485708. PubMed ID: 23137943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of T-shaped atomic force microscope cantilevers using the thermal noise method.
    Kim Y; Mandriota N; Goodnight D; Sahin O
    Rev Sci Instrum; 2020 Aug; 91(8):083703. PubMed ID: 32872926
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrodynamic methods for calibrating the normal spring constant of microcantilevers.
    Lubarsky GV; Hähner G
    Nanotechnology; 2008 Aug; 19(32):325707. PubMed ID: 21828829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of the torsional and lateral spring constants of cantilever sensors.
    Parkin JD; Hähner G
    Nanotechnology; 2014 Jun; 25(22):225701. PubMed ID: 24807706
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.