These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 24097386)

  • 1. Electrostatic-spray ionization mass spectrometry sniffing for perfume fingerprinting.
    Tobolkina E; Qiao L; Xu G; Girault HH
    Rapid Commun Mass Spectrom; 2013 Nov; 27(21):2310-6. PubMed ID: 24097386
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Perfume fingerprinting by easy ambient sonic-spray ionization mass spectrometry: nearly instantaneous typification and counterfeit detection.
    Haddad R; Catharino RR; Marques LA; Eberlin MN
    Rapid Commun Mass Spectrom; 2008 Nov; 22(22):3662-6. PubMed ID: 18946866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrostatic-spray ionization mass spectrometry.
    Qiao L; Sartor R; Gasilova N; Lu Y; Tobolkina E; Liu B; Girault HH
    Anal Chem; 2012 Sep; 84(17):7422-30. PubMed ID: 22876737
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chemical analysis and chemical imaging of fragrances and volatile compounds by low-temperature plasma ionization mass spectrometry.
    Campbell DI; Dalgleish JK; Cotte-Rodriguez I; Maeno S; Cooks RG
    Rapid Commun Mass Spectrom; 2013 Aug; 27(16):1828-36. PubMed ID: 23857928
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrospray ionization mass spectrometry fingerprinting of perfumes: Rapid classification and counterfeit detection.
    Marques Lde A; Catharino RR; Bruns RE; Eberlin MN
    Rapid Commun Mass Spectrom; 2006; 20(24):3654-8. PubMed ID: 17120298
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid classification of perfumes by extractive electrospray ionization mass spectrometry (EESI-MS).
    Chingin K; Gamez G; Chen H; Zhu L; Zenobi R
    Rapid Commun Mass Spectrom; 2008 Jul; 22(13):2009-14. PubMed ID: 18494024
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrospray ionization mass spectrometry fingerprinting of whisky: immediate proof of origin and authenticity.
    Møller JK; Catharino RR; Eberlin MN
    Analyst; 2005 Jun; 130(6):890-7. PubMed ID: 15912238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Standard addition strip for quantitative electrostatic spray ionization mass spectrometry analysis: determination of caffeine in drinks.
    Tobolkina E; Qiao L; Roussel C; Girault HH
    Talanta; 2014 Dec; 130():377-81. PubMed ID: 25159424
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid identification of regulated organic chemical compounds in toys using ambient ionization and a miniature mass spectrometry system.
    Guo X; Bai H; Lv Y; Xi G; Li J; Ma X; Ren Y; Ouyang Z; Ma Q
    Talanta; 2018 Apr; 180():182-192. PubMed ID: 29332799
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Brazil nut oil: quality control via triacylglycerol profiles provided by easy ambient sonic-spray ionization mass spectrometry.
    Funasaki M; Oliveira RS; Zanotto SP; Carioca CR; Simas RC; Eberlin MN; Alberici RM
    J Agric Food Chem; 2012 Nov; 60(45):11263-7. PubMed ID: 23113649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Commercial intermediate pressure MALDI ion mobility spectrometry mass spectrometer capable of producing highly charged laserspray ionization ions.
    Inutan ED; Wang B; Trimpin S
    Anal Chem; 2011 Feb; 83(3):678-84. PubMed ID: 21166462
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of cysteinylation of pharmaceutical-grade human serum albumin by electrospray ionization mass spectrometry and low-energy collision-induced dissociation tandem mass spectrometry.
    Kleinova M; Belgacem O; Pock K; Rizzi A; Buchacher A; Allmaier G
    Rapid Commun Mass Spectrom; 2005; 19(20):2965-73. PubMed ID: 16178042
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atmospheric pressure-thermal desorption (AP-TD)/electrospray ionization-mass spectrometry for the rapid analysis of Bacillus spores.
    Basile F; Zhang S; Shin YS; Drolet B
    Analyst; 2010 Apr; 135(4):797-803. PubMed ID: 20309450
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Linear and nonlinear regimes of electrospray signal response in analysis of urine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-MS and implications for nontarget quantification.
    Beach DG; Gabryelski W
    Anal Chem; 2013 Feb; 85(4):2127-34. PubMed ID: 23297652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid Analysis of Trace Phthalates by Spray-Inlet Microwave Plasma Torch Ionization Tandem Mass Spectrometry in Commercial Perfumes.
    Miao M; Zhao G; Cheng P; Li J; Zhang J; Pan H
    J AOAC Int; 2022 Feb; 105(1):54-61. PubMed ID: 34636904
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ion internal energy distributions validate the charge residue model for small molecule ion formation by spray methods.
    Touboul D; Jecklin MC; Zenobi R
    Rapid Commun Mass Spectrom; 2008 Apr; 22(7):1062-8. PubMed ID: 18327854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dual-source mass spectrometer with MALDI-LIT-ESI configuration.
    Smith SA; Blake TA; Ifa DR; Cooks RG; Ouyang Z
    J Proteome Res; 2007 Feb; 6(2):837-45. PubMed ID: 17269740
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.
    Leinweber FC; Schmid DG; Lubda D; Wiesmüller KH; Jung G; Tallarek U
    Rapid Commun Mass Spectrom; 2003; 17(11):1180-8. PubMed ID: 12772274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In situ analysis of agrochemical residues on fruit using ambient ionization on a handheld mass spectrometer.
    Soparawalla S; Tadjimukhamedov FK; Wiley JS; Ouyang Z; Cooks RG
    Analyst; 2011 Nov; 136(21):4392-6. PubMed ID: 21892448
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapid LC-MS method for the detection of common fragrances in personal care products without sample preparation.
    Famiglini G; Termopoli V; Palma P; Capriotti F; Cappiello A
    Electrophoresis; 2014 May; 35(9):1339-45. PubMed ID: 24273185
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.