  • 1. Optimizing of the tangential technique and supraclavicular fields in 3 dimensional conformal radiation therapy for breast cancer.
    Jabbari K; Azarmahd N; Babazade S; Amouheidari A
    J Med Signals Sens; 2013 Apr; 3(2):107-16. PubMed ID: 24098864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Regional lymph node radiotherapy in breast cancer: single anterior supraclavicular field vs. two anterior and posterior opposed supraclavicular fields.
    Houshyari M; Kashi AS; Varaki SS; Rakhsha A; Blookat ER
    Electron Physician; 2015; 7(2):1032-8. PubMed ID: 26120411
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Internal mammary node coverage: an investigation of presently accepted techniques.
    Arthur DW; Arnfield MR; Warwicke LA; Morris MM; Zwicker RD
    Int J Radiat Oncol Biol Phys; 2000 Aug; 48(1):139-46. PubMed ID: 10924983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac and lung complication probabilities after breast cancer irradiation.
    Hurkmans CW; Borger JH; Bos LJ; van der Horst A; Pieters BR; Lebesque JV; Mijnheer BJ
    Radiother Oncol; 2000 May; 55(2):145-51. PubMed ID: 10799726
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multisegmented tangential breast fields: a rational way to treat breast cancer.
    Gulybán A; Kovács P; Sebestyén Z; Farkas R; Csere T; Karácsonyi G; Dérczy K; Hideghéty K; Esik O
    Strahlenther Onkol; 2008 May; 184(5):262-9. PubMed ID: 18427757
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Dosimetric evaluation of intensity-modulated tangential beam versus conventional tangential irradiation for breast cancer].
    Huang XB; Jiang GL; Chen JY; Chen LF; Hu WG
    Ai Zheng; 2006 Jul; 25(7):855-60. PubMed ID: 16831277
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with or without intensity modulation.
    Hurkmans CW; Cho BC; Damen E; Zijp L; Mijnheer BJ
    Radiother Oncol; 2002 Feb; 62(2):163-71. PubMed ID: 11937243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Regional radiotherapy to axilla and supraclavicular fossa for adjuvant breast treatment: a comparison of four techniques.
    Jephcott CR; Tyldesley S; Swift CL
    Int J Radiat Oncol Biol Phys; 2004 Sep; 60(1):103-10. PubMed ID: 15337545
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy.
    Landau D; Adams EJ; Webb S; Ross G
    Radiother Oncol; 2001 Sep; 60(3):247-55. PubMed ID: 11514004
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: a dosimetric comparison.
    Rudat V; Alaradi AA; Mohamed A; Ai-Yahya K; Altuwaijri S
    Radiat Oncol; 2011 Mar; 6():26. PubMed ID: 21418616
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer.
    Al-Rahbi ZS; Al Mandhari Z; Ravichandran R; Al-Kindi F; Davis CA; Bhasi S; Satyapal N; Rajan B
    J Med Phys; 2013 Jan; 38(1):22-9. PubMed ID: 23531607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Planning comparison of intensity modulated radiation therapy delivered with 2 tangential fields versus 3-dimensional conformal radiotherapy for cardiac sparing in women with left-sided breast cancer.
    Taunk NK; Prosnitz RG
    Pract Radiat Oncol; 2012; 2(4):248-256. PubMed ID: 24674160
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
    Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
    J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accelerated partial breast irradiation: a dosimetric comparison of three different techniques.
    Weed DW; Edmundson GK; Vicini FA; Chen PY; Martinez AA
    Brachytherapy; 2005; 4(2):121-9. PubMed ID: 15893265
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric comparison between different tangential field arrangements during left-sided breast cancer radiotherapy.
    Robatjazi M; Baghani HR; Porouhan P
    Radiol Phys Technol; 2021 Sep; 14(3):226-237. PubMed ID: 34043155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Dosimetric analysis of radiotherapy with middle shielding blocks of different widths at the lower cervical supraclavicular field for stage N2-3 nasopharyngeal carcinoma].
    Li FM; Luo W; He ZC; Zhang L; Sun Y; Qin WJ; Lu LX; Han F; Liu XQ; Liu MZ
    Ai Zheng; 2007 Oct; 26(10):1127-32. PubMed ID: 17927886
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new isocentric technique for exact geometric matching in the radiotherapy of the breast and ipsilateral supraclavicular fossa using dual asymmetric jaws.
    Romeo N
    Phys Med; 2012 Oct; 28(4):281-7. PubMed ID: 22056674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT.
    Duan J; Shen S; Spencer SA; Ahmed RS; Popple RA; Ye SJ; Brezovich IA
    Int J Radiat Oncol Biol Phys; 2004 Nov; 60(3):959-72. PubMed ID: 15465215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric evaluation of 3-D conformal and intensity-modulated radiotherapy for breast cancer after conservative surgery.
    Mansouri S; Naim A; Glaria L; Marsiglia H
    Asian Pac J Cancer Prev; 2014; 15(11):4727-32. PubMed ID: 24969911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric comparison of conventional and forward-planned intensity-modulated techniques for comprehensive locoregional irradiation of post-mastectomy left breast cancers.
    Cavey ML; Bayouth JE; Endres EJ; Pena JM; Colman M; Hatch S
    Med Dosim; 2005; 30(2):107-16. PubMed ID: 15922178
    [TBL] [Abstract][Full Text] [Related]  