These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

388 related articles for article (PubMed ID: 24099976)

  • 21. Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure.
    Hauser RG; Hayes DL
    Heart Rhythm; 2009 May; 6(5):605-10. PubMed ID: 19285920
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Long-term electrical survival analysis of Riata and Riata ST silicone leads: National Veterans Affairs experience.
    Sung RK; Massie BM; Varosy PD; Moore H; Rumsfeld J; Lee BK; Keung E
    Heart Rhythm; 2012 Dec; 9(12):1954-61. PubMed ID: 22871583
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transvenous implantable cardioverter-defibrillator lead reliability: implications for postmarket surveillance.
    Kramer DB; Hatfield LA; McGriff D; Ellis CR; Gura MT; Samuel M; Retel LK; Hauser RG
    J Am Heart Assoc; 2015 May; 4(6):e001672. PubMed ID: 26025935
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transvenous Implantable Cardioverter-Defibrillator (ICD) Lead Performance: A Meta-Analysis of Observational Studies.
    Providência R; Kramer DB; Pimenta D; Babu GG; Hatfield LA; Ioannou A; Novak J; Hauser RG; Lambiase PD
    J Am Heart Assoc; 2015 Oct; 4(11):. PubMed ID: 26518666
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Longevity of Sprint Fidelis implantable cardioverter-defibrillator leads and risk factors for failure: implications for patient management.
    Hauser RG; Maisel WH; Friedman PA; Kallinen LM; Mugglin AS; Kumar K; Hodge DO; Morrison TB; Hayes DL
    Circulation; 2011 Feb; 123(4):358-63. PubMed ID: 21242478
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparative study of the failure rates among 3 implantable defibrillator leads.
    van Malderen SC; Szili-Torok T; Yap SC; Hoeks SE; Zijlstra F; Theuns DA
    Heart Rhythm; 2016 Dec; 13(12):2299-2305. PubMed ID: 27496586
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts.
    Ploux S; Swerdlow CD; Strik M; Welte N; Klotz N; Ritter P; Haïssaguerre M; Bordachar P
    J Cardiovasc Electrophysiol; 2018 Aug; 29(8):1125-1134. PubMed ID: 29858871
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Risk factors for implantable defibrillator lead fracture in a recalled and a nonrecalled lead.
    Morrison TB; Rea RF; Hodge DO; Crusan D; Koestler C; Asirvatham SJ; Bradley D; Shen WK; Munger TM; Hammill SC; Friedman PA
    J Cardiovasc Electrophysiol; 2010 Jun; 21(6):671-7. PubMed ID: 20082653
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads.
    Kubala M; Traullé S; Leborgne L; Hermida JS
    Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lead Integrity Alert Is Useful for Assessment of Performance of Biotronik Linox Leads.
    Steinberg C; Padfield GJ; Hahn E; Flavelle S; McILROY C; VAN Bremen O; Yeung-Lai-Wah JA; Kerr CR; Deyell MW; Tung SK; Andrade JG; Bennett MT; Bashir JG; Krahn AD; Chakrabarti S
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1340-5. PubMed ID: 26471861
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Prospective long-term evaluation of Optim-insulated (Riata ST Optim and Durata) implantable cardioverter-defibrillator leads.
    Cairns JA; Epstein AE; Rickard J; Connolly SJ; Buller C; Wilkoff BL; Pogue J; Themeles E; Healey JS
    Heart Rhythm; 2014 Dec; 11(12):2156-62. PubMed ID: 25131665
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of Sprint Fidelis and Riata defibrillator lead failure rates.
    Fazal IA; Shepherd EJ; Tynan M; Plummer CJ; McComb JM
    Int J Cardiol; 2013 Sep; 168(2):848-52. PubMed ID: 23138013
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Failure of a novel silicone-polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions.
    Hauser RG; Abdelhadi RH; McGriff DM; Kallinen Retel L
    Europace; 2013 Feb; 15(2):278-83. PubMed ID: 22915789
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator.
    Danik SB; Mansour M; Singh J; Reddy VY; Ellinor PT; Milan D; Heist EK; d'Avila A; Ruskin JN; Mela T
    Heart Rhythm; 2007 Apr; 4(4):439-42. PubMed ID: 17399630
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect.
    Hauser RG; McGriff D; Retel LK
    Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.