These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation. Binder RK; Webb JG; Toggweiler S; Freeman M; Barbanti M; Willson AB; Alhassan D; Hague CJ; Wood DA; Leipsic J JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010 [TBL] [Abstract][Full Text] [Related]
3. Frequency of conduction disturbances after Edwards SAPIEN percutaneous valve implantation. Laynez A; Ben-Dor I; Barbash IM; Hauville C; Sardi G; Maluenda G; Xue Z; Satler LF; Pichard AD; Lindsay J; Waksman R Am J Cardiol; 2012 Oct; 110(8):1164-8. PubMed ID: 22770935 [TBL] [Abstract][Full Text] [Related]
4. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. Siontis GC; Jüni P; Pilgrim T; Stortecky S; Büllesfeld L; Meier B; Wenaweser P; Windecker S J Am Coll Cardiol; 2014 Jul; 64(2):129-40. PubMed ID: 25011716 [TBL] [Abstract][Full Text] [Related]
5. Electrophysiological evaluation of atrioventricular conduction disturbances in transcatheter aortic valve implantation with Edwards SAPIEN prosthesis. Eksik A; Gul M; Uyarel H; Surgit O; Yildirim A; Uslu N; Aksu H; Turen S; Uzun F; Satılmısoglu H; Erol MK; Bakir I J Invasive Cardiol; 2013 Jun; 25(6):305-9. PubMed ID: 23735359 [TBL] [Abstract][Full Text] [Related]
6. [Transcatheter aortic valve implantation and conduction disturbances]. Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339 [TBL] [Abstract][Full Text] [Related]
7. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience. Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074 [TBL] [Abstract][Full Text] [Related]
8. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve. Franzoni I; Latib A; Maisano F; Costopoulos C; Testa L; Figini F; Giannini F; Basavarajaiah S; Mussardo M; Slavich M; Taramasso M; Cioni M; Longoni M; Ferrarello S; Radinovic A; Sala S; Ajello S; Sticchi A; Giglio M; Agricola E; Chieffo A; Montorfano M; Alfieri O; Colombo A Am J Cardiol; 2013 Aug; 112(4):554-9. PubMed ID: 23726173 [TBL] [Abstract][Full Text] [Related]
9. The incidence of transcatheter aortic valve implantation-related heart block in self-expandable Medtronic CoreValve and balloon-expandable Edwards valves. Liang M; Devlin G; Pasupati S J Invasive Cardiol; 2012 Apr; 24(4):173-6. PubMed ID: 22477754 [TBL] [Abstract][Full Text] [Related]
10. Managing heart block after transcatheter aortic valve implantation: from monitoring to device selection and pacemaker indications. Urena M; Rodés-Cabau J EuroIntervention; 2015 Sep; 11 Suppl W():W101-5. PubMed ID: 26384171 [TBL] [Abstract][Full Text] [Related]
11. Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis. Baan J; Yong ZY; Koch KT; Henriques JP; Bouma BJ; Vis MM; Cocchieri R; Piek JJ; de Mol BA Am Heart J; 2010 Mar; 159(3):497-503. PubMed ID: 20211315 [TBL] [Abstract][Full Text] [Related]
12. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System. Testa L; Latib A; De Marco F; De Carlo M; Agnifili M; Latini RA; Petronio AS; Ettori F; Poli A; De Servi S; Ramondo A; Napodano M; Klugmann S; Ussia GP; Tamburino C; Brambilla N; Colombo A; Bedogni F Circulation; 2013 Mar; 127(12):1300-7. PubMed ID: 23443735 [TBL] [Abstract][Full Text] [Related]
13. Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis. Godin M; Eltchaninoff H; Furuta A; Tron C; Anselme F; Bejar K; Sanchez-Giron C; Bauer F; Litzler PY; Bessou JP; Cribier A Am J Cardiol; 2010 Sep; 106(5):707-12. PubMed ID: 20723650 [TBL] [Abstract][Full Text] [Related]
14. Recovery of atrioventricular conduction in patients with heart block after transcatheter aortic valve replacement. Raelson CA; Gabriels J; Ruan J; Ip JE; Thomas G; Liu CF; Cheung JW; Lerman BB; Patel A; Markowitz SM J Cardiovasc Electrophysiol; 2017 Oct; 28(10):1196-1202. PubMed ID: 28677917 [TBL] [Abstract][Full Text] [Related]
15. Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation. Roten L; Wenaweser P; Delacrétaz E; Hellige G; Stortecky S; Tanner H; Pilgrim T; Kadner A; Eberle B; Zwahlen M; Carrel T; Meier B; Windecker S Am J Cardiol; 2010 Nov; 106(10):1473-80. PubMed ID: 21059439 [TBL] [Abstract][Full Text] [Related]
16. Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation. Aktug Ö; Dohmen G; Brehmer K; Koos R; Altiok E; Deserno V; Herpertz R; Autschbach R; Marx N; Hoffmann R Int J Cardiol; 2012 Sep; 160(1):26-30. PubMed ID: 21458085 [TBL] [Abstract][Full Text] [Related]
17. Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. Nuis RJ; Van Mieghem NM; Schultz CJ; Tzikas A; Van der Boon RM; Maugenest AM; Cheng J; Piazza N; van Domburg RT; Serruys PW; de Jaegere PP Eur Heart J; 2011 Aug; 32(16):2067-74. PubMed ID: 21622979 [TBL] [Abstract][Full Text] [Related]