166 related articles for article (PubMed ID: 24104824)
1. High-sensitivity roll-angle interferometer.
Le Y; Hou W; Hu K; Shi K
Opt Lett; 2013 Sep; 38(18):3600-3. PubMed ID: 24104824
[TBL] [Abstract][Full Text] [Related]
2. Measurement of straightness without Abbe error using an enhanced differential plane mirror interferometer.
Jin T; Ji H; Hou W; Le Y; Shen L
Appl Opt; 2017 Jan; 56(3):607-610. PubMed ID: 28157917
[TBL] [Abstract][Full Text] [Related]
3. High resolution and stability roll angle measurement method for precision linear displacement stages.
Jin T; Xia G; Hou W; Le Y; Han S
Rev Sci Instrum; 2017 Feb; 88(2):023102. PubMed ID: 28249520
[TBL] [Abstract][Full Text] [Related]
4. Five-degrees-of-freedom measurement system based on a monolithic prism and phase-sensitive detection technique.
Huang P; Li Y; Wei H; Ren L; Zhao S
Appl Opt; 2013 Sep; 52(26):6607-15. PubMed ID: 24085139
[TBL] [Abstract][Full Text] [Related]
5. Note: Enhancing the sensitivity of roll-angle measurement with a novel interferometric configuration based on waveplates and folding mirror.
Qi J; Wang Z; Huang JH; Yu B; Gao J; Donati S
Rev Sci Instrum; 2016 Mar; 87(3):036106. PubMed ID: 27036839
[TBL] [Abstract][Full Text] [Related]
6. Laser homodyne straightness interferometer with simultaneous measurement of six degrees of freedom motion errors for precision linear stage metrology.
Lou Y; Yan L; Chen B; Zhang S
Opt Express; 2017 Mar; 25(6):6805-6821. PubMed ID: 28381023
[TBL] [Abstract][Full Text] [Related]
7. Heterodyne grating interferometer based on a quasi-common-optical-path configuration for a two-degrees-of-freedom straightness measurement.
Lee JY; Hsieh HL; Lerondel G; Deturche R; Lu MP; Chen JC
Appl Opt; 2011 Mar; 50(9):1272-9. PubMed ID: 21460999
[TBL] [Abstract][Full Text] [Related]
8. Linear diffraction grating interferometer with high alignment tolerance and high accuracy.
Cheng F; Fan KC
Appl Opt; 2011 Aug; 50(22):4550-6. PubMed ID: 21833131
[TBL] [Abstract][Full Text] [Related]
9. Measurement of angle and axis of rotation in a carousel interferometer: a detailed analysis.
Hussain G; Ikram M
Appl Opt; 2010 Feb; 49(6):1025-31. PubMed ID: 20174172
[TBL] [Abstract][Full Text] [Related]
10. Resolution-enhanced heterodyne laser interferometer with differential configuration for roll angle measurement.
Qi J; Wang Z; Huang J; Gao J
Opt Express; 2018 Apr; 26(8):9634-9644. PubMed ID: 29715912
[TBL] [Abstract][Full Text] [Related]
11. Roll angle measurement system based on differential plane mirror interferometer.
Shi K; Su J; Hou W
Opt Express; 2018 Aug; 26(16):19826-19834. PubMed ID: 30119303
[TBL] [Abstract][Full Text] [Related]
12. Laser straightness interferometer system with rotational error compensation and simultaneous measurement of six degrees of freedom error parameters.
Chen B; Xu B; Yan L; Zhang E; Liu Y
Opt Express; 2015 Apr; 23(7):9052-73. PubMed ID: 25968740
[TBL] [Abstract][Full Text] [Related]
13. Heterodyne interferometer with two parallel-polarized input beams for high-resolution roll angle measurement.
Qi J; Wang Z; Huang J; Wang Q; Gao J
Opt Express; 2019 May; 27(10):13820-13830. PubMed ID: 31163841
[TBL] [Abstract][Full Text] [Related]
14. Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer.
Tang S; Wang Z; Gao J; Guo J
Rev Sci Instrum; 2014 Apr; 85(4):045110. PubMed ID: 24784662
[TBL] [Abstract][Full Text] [Related]
15. A heterodyne interferometer for angle metrology.
Hahn I; Weilert M; Wang X; Goullioud R
Rev Sci Instrum; 2010 Apr; 81(4):045103. PubMed ID: 20441364
[TBL] [Abstract][Full Text] [Related]
16. Modified Fabry-Perot interferometer for displacement measurement in ultra large measuring range.
Chang CP; Tung PC; Shyu LH; Wang YC; Manske E
Rev Sci Instrum; 2013 May; 84(5):053105. PubMed ID: 23742530
[TBL] [Abstract][Full Text] [Related]
17. Note: A small roll angle measurement method with enhanced resolution based on a heterodyne interferometer.
Tang S; Wang Z; Li M; Zhang W; Yang F; Zhang X
Rev Sci Instrum; 2015 Sep; 86(9):096104. PubMed ID: 26429491
[TBL] [Abstract][Full Text] [Related]
18. Improved angle interferometer based on total internal reflection.
Zhou W; Cai L
Appl Opt; 1999 Mar; 38(7):1179-85. PubMed ID: 18305729
[TBL] [Abstract][Full Text] [Related]
19. Michelson interferometer for precision angle measurement.
Ikram M; Hussain G
Appl Opt; 1999 Jan; 38(1):113-20. PubMed ID: 18305593
[TBL] [Abstract][Full Text] [Related]
20. Self-referenced rectangular path cyclic interferometer with polarization phase shifting.
Sarkar S; Ghosh N; Chakraborty S; Bhattacharya K
Appl Opt; 2012 Jan; 51(1):126-32. PubMed ID: 22270421
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]